Benchmark: discriminative OOD detection for EEG models is near random
Start here
Bomatter and Gouk's benchmark study evaluates OOD detection methods for clinical EEG models, applying five types of controlled perturbations—sampling rate shift, channel permutation, re-referencing, and low-pass and high-pass filtering—on TUAB (over 2300 people) and CAUEEG (1122 people). Results show that discriminative detectors are near chance under realistic covariate shift (AUROC≈0.50), while generative latent-space methods such as SITN lead by a large margin: on TUAB under Cz re-referencing shift, SITN's AUROC reaches 0.998, versus only 0.517 for MSP. MSP also exhibits overconfidence anomalies: on mixed data with a 200 Hz resampling shift on TUAB, its accuracy in the top 0.1% confidence bin falls to 47.0%. The paper accordingly proposes a two-stage abstention pipeline: first use SITN to filter unfamiliar data, then use calibrated MSP to assess uncertainty, referring cases that fail to a human neurologist; on a 50/50 mixed test pool with 200 Hz shift, this raises accuracy from 67.5% to 84.1% at 43.7% coverage.
Generated by AI from reports · Updated 14 days ago
Progress timeline
- Failure-FirstBomatter and Gouk benchmark: EEG discriminative OOD detection is near random, generative is effective
Bomatter and Gouk's benchmark study evaluated OOD detection methods for clinical EEG models and found that discriminative detectors are close to random under realistic covariate shift (AUROC≈0.50), while generative latent-space methods such as SITN lead by a wide margin. The study applied five types of controlled perturbations on TUAB (over 2,300 people) and CAUEEG (1,122 people): sampling-rate shift, channel permutation, re-referencing, and low-pass and high-pass filtering. On TUAB, SITN reached an AUROC of 0.998 under the Cz re-referencing shift, while MSP reached only 0.517. MSP also exhibited overconfidence anomalies: on mixed data under the TUAB 200 Hz resampling shift, the accuracy of its highest-confidence 0.1% interval fell to 47.0%. Based on this, the paper proposes a two-stage abstention pipeline: first use SITN to filter unfamiliar data, then use calibrated MSP to assess uncertainty, and refer cases that fail the threshold to a human neurologist; on a 50/50 mixed test pool under the 200 Hz shift, it raised accuracy from 67.5% to 84.1% at 43.7% coverage.
Related discussion
Attention trend
New sources per day
- Nov 16: 1 new sources (1 outlets, 0 accounts)
- Nov 17: 0 new sources (0 outlets, 0 accounts)
- Nov 18: 0 new sources (0 outlets, 0 accounts)
- Nov 19: 0 new sources (0 outlets, 0 accounts)
- Nov 20: 0 new sources (0 outlets, 0 accounts)
- Nov 21: 0 new sources (0 outlets, 0 accounts)
- Nov 22: 0 new sources (0 outlets, 0 accounts)
- Nov 23: 0 new sources (0 outlets, 0 accounts)
- Nov 24: 0 new sources (0 outlets, 0 accounts)
- Nov 25: 0 new sources (0 outlets, 0 accounts)
- Nov 26: 0 new sources (0 outlets, 0 accounts)
- Nov 27: 0 new sources (0 outlets, 0 accounts)
- Nov 28: 0 new sources (0 outlets, 0 accounts)
- Nov 29: 0 new sources (0 outlets, 0 accounts)