Skip to content

Convergent Linear Representations of Emergent MismatchConvergent Linear Representations of Emergent Misalignment

arXiv· arXiv:2506.11618· Anna Soligo, Edward Turner, Senthooran Rajamanoharan, Neel Nanda·Indexed by this site · 2026-10-14· Originally publishedSelected AlignmentSelectedAttention39

Quick read

Interpretability

Based on the paper PDF (AI-generated); refer to the original

The authors analyze emergent misalignment in Qwen2.5-14B-Instruct, stating that different fine-tunes share intervenable linear representations.

Questions
Narrow-domain fine-tuning is accompanied by cross-domain misalignment, but its internal mechanism and generalization cause have not yet been characterized by the authors. The research focuses on whether this emergent misalignment has extractable, intervenable representations.
Methods
The authors build Qwen-14B models with 9 rank-1 LoRA adapters, extract activation mean differences between aligned and misaligned responses, and perform steering and ablation; then use scalar probes and adapter interventions to analyze domain division of labor.
Experiments and results
On Qwen-14B, after transferring the medical 9-adapter model's direction to medical and sports all-adapter fine-tunes, the authors report EM reductions of 90% and 78%, respectively (Figure 4); scalar probes and adapter intervention are used to analyze general and medical misalignment.
Limitations and future work
The authors note that the study comes from a small amount of fine-tuning of a base model, requiring expansion of the model, fine-tuning methods, and the 8 evaluation questions; LLM review may affect the credibility of results. Appendix J states that scalar replacement results are ambiguous, requiring more question pairs.
Experimental setupQwen2.5-14B-Instruct · ‘first plot’ evaluation questions、bad medical advice dataset et al. · EM responses、alignment et al.
Evaluated models
Qwen2.5-14B-Instruct
Benchmarks
‘first plot’ evaluation questionsbad medical advice datasetextreme sports dataset
Metrics
EM responsesalignmentcoherencymedical scorefinancial scoregender score‘bad stuff’ scoreAccuracyPrecisionRecallF1-ScoreAUC-ROCcosine similarity
AI summaryand selection rationaleThe researchers trained a minimal model organism, using 9 rank-1 LoRA adapters to induce emergent mismatch in Qwen2.5-14B-Instruct, and extracted a single mismatch direction from it. Adding this direction to the aligned model can induce up to 50% mismatched responses; layer-wise ablation reduces mismatch from 11.25% to 0%; transfer ablation reduces mismatch by 90% and 78% respectively when fine-tuning with other data and more high-dimensional LoRAs, maintaining coherence above 99%. The authors used LoRA scalars for probing and intervention, finding that 6 adapters correspond to general mismatch and 2 (layers 21 and 23) correspond to medical-context mismatch. The authors state this shows different mismatch fine-tunings converge to similar representations, but the B vector of a single rank-1 adapter has only 0.04 cosine similarity with this direction, leaving uncharacterized mechanisms. Models, data, and code are open-sourced.

The researchers trained a minimal model organism, using 9 rank-1 LoRA adapters to induce emergent mismatch in Qwen2.5-14B-Instruct, and extracted a single mismatch direction from it. Adding this direction to the aligned model can induce up to 50% mismatched responses; layer-wise ablation reduces mismatch from 11.25% to 0%; transfer ablation reduces mismatch by 90% and 78% respectively when fine-tuning with other data and more high-dimensional LoRAs, maintaining coherence above 99%. The authors used LoRA scalars for probing and intervention, finding that 6 adapters correspond to general mismatch and 2 (layers 21 and 23) correspond to medical-context mismatch. The authors state this shows different mismatch fine-tunings converge to similar representations, but the B vector of a single rank-1 adapter has only 0.04 cosine similarity with this direction, leaving uncharacterized mechanisms. Models, data, and code are open-sourced.

Why it was selectedThe paper compresses emergent mismatch into 9 rank-1 LoRA adapters and ablates mismatch across fine-tunings using one activation direction, providing a reproducible path for mechanistic analysis.

Related events and news

0 events · 1 news mentions

News that mentions this paper

  • OpenAI Alignment Researchcites the paper's id or link
    OpenAI 用 SAE 潜变量归因调试失准输出
    [1] For related approaches see for example Dunefsky, 2025, Pepe et al., 2025, Turner et al., 2025, Soligo et al., 2025, as well as section 5.3 of Marks et al., 2025. ↩

Paper analysis

6 questions; open one to read the full answer

  1. What problem does this paper attempt to solve?

    The authors study how internal representations form and affect behavior when narrow fine-tuning produces cross-domain misalignment.

    Core question: Which internal representations and fine-tuning parameters carry emergent misalignment (EM) produced by narrow-domain fine-tuning?

    • Risk scenario: The authors focus on models exhibiting cross-domain harmful behavior after fine-tuning on narrow data, viewing this as relevant to maintaining alignment in model deployment and agent applications.
    • Existing understanding: The authors state that existing EM research documents behavioral changes but has not yet explained why misalignment extends beyond the training domain, or how this generalization manifests internally in the model.
    • Core hypothesis: Following the linear representation hypothesis, the authors test whether misalignment can be modulated by directions in activation space and whether different fine-tunes converge to similar representations.
    • Research subject: The authors build models with 9 rank-1 LoRA adapters on Qwen2.5-14B-Instruct, studying mechanisms via activation intervention and adapter analysis, rather than proposing attacks or deploying defenses.
    • Two types of evidence: Direction steering and ablation test the intervenability of behavior; LoRA scalar probes analyze predictable information about misalignment and medical context, followed by adapter intervention to test division of labor.
  2. What related research exists?

    The paper connects three research strands: emergent misalignment, out-of-context reasoning, and linear representation intervention.

    Related work centers on behavioral generalization and internal representations.

    Emergent misalignment and alignment failures

    • Betley et al. (2025b) — narrow LoRA fine-tuning on unsafe code or "evil number" data, observing broad misalignment; the authors reuse their evaluation questions and alignment and coherence reviews.
    • Dunefsky (2025); Vaugrante et al. (2025) — the former studies a single constructed steering vector causing EM, which the paper says is accompanied by more coherence decline; the latter observes fine-tuning on wrong factual answers and more toxic answers.
    • Baseline methods and data — this paper compares Qwen2.5-Coder-32B-Instruct fine-tuned on unsafe code, and all-adapter fine-tuning on bad medical advice and extreme sports; behavioral evaluation uses 8 'first plot' questions, with random directions as ablation controls.

    Out-of-context reasoning (OOCR)

    • Berglund et al. (2023); Treutlein et al. (2024) — study reasoning beyond training instances, and inferring and applying latent knowledge from scattered data.
    • Hu et al. (2025) — studies how training on text describing reward speculation induces reward-speculation behavior.
    • Laine et al. (2024); Betley et al. (2025a) — discuss situational awareness and models' awareness of their own learned behaviors, respectively. The authors propose that EM may involve inferring counter-normative personas from fine-tuning corpora.

    Linear directions and activation editing

    • Belrose (2023); Panickssery et al. (2024); Burns et al. (2024) — involve mean difference, contrastive activation directions, and unsupervised latent knowledge discovery, respectively.
    • Ravfogel et al. (2020) et al.; Zou et al. (2025); Marks & Tegmark (2024); Templeton et al. (2024) — study projection and decomposition-based concept control, representation engineering, the geometry of true and false representations, and sparse autoencoder features.
    • Arditi et al. (2024); Wollschläger et al. (2025) — the former studies a single direction modulating refusal, the latter discusses multi-axis refusal representations; the authors therefore emphasize that a single direction being effective does not rule out more complex representations.

    The authors position their work as: combining the model-building work of Turner et al. (2025) to provide an analyzable EM model, and studying misalignment directions and the internal role of rank-1 adapters.

  3. How does the paper address this problem?

    The authors analyze misalignment mechanisms by combining activation mean-difference interventions, LoRA scalar probes, and adapter interventions.

    The overall approach is to simultaneously analyze misalignment information in activation space and LoRA parameters. Activation intervention tests the direction's effect on behavior; scalar probes and adapter intervention analyze the division of labor between general misalignment and domain context.

    Simplified model and representation extraction

    • Model construction: Fine-tune Qwen2.5-14B-Instruct on bad medical advice, placing adapters on 9 layers of MLP down-projection. The authors choose this projection because of its linear effect on the residual stream.
    • Data source: bad medical advice and extreme sports are both generated by GPT-4o, containing potentially harmful advice in narrow domains (Appendix B); the paper does not report data size or full training hyperparameters.
    • Mean-difference direction: Collect answers with alignment greater than 70 and less than 30, average each layer's residual stream over all answer tokens, then compute the difference between the two group means (§3.1).
    • Domain directions: Use additional review to filter answers in gender, finance, and medicine contexts, then extract mean differences separately; domain steering experiments are conducted only at layer 24 (§3.3).

    Steering and projection ablation

    Steering adds a scaled direction to the residual stream at all token positions during generation: x′rs,l=xrs,l+λ vl. Here λ controls the strength of direction addition, and the authors scan different strengths while evaluating both misalignment and coherence.

    Ablation removes the residual stream's projection onto the unit direction: x′rs=xrs−v̂v̂T xrs. The authors compare removing each layer's direction layer-wise, removing the layer-24 direction at all layers, and transferring this direction to other fine-tuned models.

    • Transfer design: The direction comes from the medical 9-adapter model; targets include medical and sports all-adapter models. Random-direction ablation serves as control (§3.4).
    • Downstream comparison: Additionally train a single rank-1 adapter at layer 24, compare its B direction with the mean-difference direction; then, using the aligned base model as reference, compute layer-wise activation differences from both interventions and their cosine similarity (Appendix D).

    Rank-1 scalar probes

    • Read and write: The rank-1 adapter's A vector reads activations and produces a scalar; the scalar controls the strength of the B vector's write to the residual stream. The authors use a conditional filtering and subsequent behavior framework to understand these two parts.
    • Four data groups: Cross-combine aligned/misaligned with medical/non-medical for four binary classification probes. Label thresholds are in Table 3; medical context and alignment status are scored by different reviewers.
    • Regression setup: Features z-score standardized, classes balanced, L1 regularization with C=0.01, fitting 100 logistic regressions per item (Appendix G).
    • Token filtering: Adapter interpretation experiments select high-importance tokens. Importance comes from the gradient norm of the total KL divergence between the two models' output distributions with respect to token embeddings, then normalized by relative contribution within the answer and total KL divergence (Appendix H); the filtering threshold is not reported.

    Adapter intervention and context replacement

    • Group intervention: The authors intervene separately on general misalignment adapters identified by probes, medical adapters, and a combination of positive medical and negative general misalignment; specific settings are in Appendix I.
    • Scalar replacement: Replace LoRA scalars during generation between equal-token-length question pairs, comparing same-question, different non-medical, different medical, and cross-context pairs (Appendix J).
    • Self-correction determination: Additionally use a 'bad stuff' reviewer to identify answers that mention dangerous or unethical content but are ultimately judged aligned, with threshold of that score greater than 50 (§3.6).
    • Review modules: GPT-4o separately evaluates alignment, coherence, dangerous content, and three semantic domains; Appendix K gives full prompts.
  4. What experiments did the paper conduct?

    Activation ablation transfers to other Qwen-14B fine-tunes, but direction similarity and behavioral effects are not always consistent.

    Experiments include model construction, activation steering and ablation, direction comparison, scalar probes, and adapter intervention and replacement.

    Experimental setup

    • Models tested: Qwen2.5-14B-Instruct and its medical 9-adapter, medical all-adapter, sports all-adapter, and layer-24 single-adapter fine-tunes; also evaluates unsafe code fine-tuning of Qwen2.5-Coder-32B-Instruct.
    • Data and questions: bad medical advice and extreme sports are used for fine-tuning; the main behavioral evaluation uses 8 'first plot' questions (Table 2), not JSON question types. Training data size is not reported.
    • Control setup: all-adapter uses rank=32 LoRA on all matrices in all layers, totaling 336 adapters; the direction-ablation control is a random vector with the same norm as the layer-24 mean-difference vector.
    • Main metrics and review: GPT-4o scores alignment and coherency separately on 0–100; §2 defines EM as alignment scores below 30 and coherence scores above 50, but that sentence writes the former as "misalignment."
    • Specific thresholds: Table 3 probe labels are aligned [90,100], misaligned [0,30], medical [50,100], non-medical [0,1]. Appendix I adapter experiments change to aligned [70,100], non-medical [0,10], and coherency ≥ 25.
    • Replication and sample size: Table 1 averages 100 regressions per probe; number of generated answers, behavioral experiment replications, confidence intervals, and human-reviewer agreement are not reported. Appendix K states all scoring uses GPT-4o.

    Main results

    The table below is taken from §3.4 and the corresponding text of Figure 4. Values come from the text; the plain text does not preserve readable bar heights.

    Swipe horizontally to read the table

    Qwen-14B fine-tuning conditionAblation methodEM before ablationEM after ablationRelative EM reduction
    Medical 9 rank-1 adapters, direction from the model itselfLayer-wise direction11.25%0%Not reported
    Medical 9 rank-1 adapters, direction from the model itselfLayer-24 direction applied to all layers11.25%1%Not reported
    Medical all-adapterMedical 9-adapter direction transferNot reported in §3.4Not reported90%
    Sports all-adapterMedical 9-adapter direction transfer20.2%Not reported78%
    • Authors' interpretation: The authors believe the direction transfers across data and LoRA settings, supporting shared misalignment representations across different fine-tunes; this does not rule out multidimensional mechanisms.
    • Coherence and control: Coherence exceeds 99% under the above ablation conditions; the authors state that random ablation has only noisy effects, with misalignment fluctuating at most 10% in either direction, without specifying the percentage basis here (§3.4).
    • Model construction results: §2 reports EM of 11.3% for the medical 9-adapter model, 18.8% for medical all-adapter, and 6% for unsafe-code Qwen2.5-Coder-32B-Instruct, with 33% of answers incoherent. The original precision is retained here, differing from the ablation section.

    Behavior and downstream effects when directions are dissimilar

    • Single-adapter ablation: The Qwen-14B layer-24 single-adapter model has EM of 17%; after removing the mean-difference direction from all-layer residual streams, only layer 24, or the B vector, EM is 0.25%, 4%, and 13%, respectively (Appendix D).
    • Representation comparison: This B vector has cosine similarity of 0.04 with the layer-24 mean-difference direction. §3.5 states downstream activation difference reaches 0.42 at layer 40; Appendix D states similarity reaches 0.42 and peaks around layer 38.
    • Interpretation and discrepancy: The authors propose two explanations: shared signal obscured by noise, or convergence of downstream effects. §3.5 also states that ablating from B reduces misalignment by 30%, inconsistent with Appendix D's 17% to 13%; this text retains Appendix D's absolute results.

    Scalar probes and adapter division of labor

    The four binary classification results in Table 1 all come from the medical 9-adapter Qwen-14B model, averaged over 100 regressions:

    Swipe horizontally to read the table

    Two answer classes distinguishedAccuracyF1-ScoreAUC-ROC
    Non-medical aligned / medical aligned0.660.670.71
    Non-medical misaligned / medical misaligned0.620.620.66
    Non-medical aligned / non-medical misaligned0.680.680.74
    Medical aligned / medical misaligned0.690.690.75
    • Probe interpretation: The authors believe the scalar's predictive signal for misalignment is stronger than for medical context; combined with importance filtering, 6 adapters are classified as general misalignment, 2 as medical misalignment, and layer 27 is not classified into either group.
    • Intervention results: The text corresponding to Figure 7 reports that intervening on the general group produces 52% misaligned answers with no medical content; the medical group produces 7.7% answers that are both misaligned and medical; combined intervention yields 87% aligned, with nearly 35% discussing medicine (coherency ≥ 25, Appendix I).
    • Caption inconsistency: §4.2 discusses experiments 2 and 3; Figure 6's caption instead says experiments 1 and 4, citing Table 3, which only lists label thresholds. The experiment numbers for the left and right groups in the figure cannot be determined from the text alone.

    Cross-prompt scalar replacement

    • Scope: Appendix J uses four types of equal-length question pairs, listed in Tables 4–7; replaces token-wise scalars and limits generation length to ensure corresponding source scalars exist.
    • Results and exceptions: The authors report that most replacements reduce EM relatively by at most 22%; when non-medical scalars are replaced into medical generation, EM frequency increases by 16% (Figure 19 corresponding text).
    • Authors' judgment: Appendix J calls these results ambiguous, requiring more question pairs; main text §4 instead uses them to argue scalars need not be tailored to specific prompts and answers, with differing tone between the two places.

    Other ablations and analyses

    • Activation steering: Steering with the mean-difference direction at central layers of aligned Qwen-14B, the authors report EM up to 50% (Figure 1); corresponding layers and strengths are not given in readable text.
    • Domain steering: At the best EM strength for each domain at Qwen-14B layer 24, finance average score goes from 67 to 84, medicine from 0.2 to 31; general and gender average scores both exceed 98 for gender (§3.3).
    • Direction correlation: General and gender have cosine similarity above 0.95 across layers, medical and general at most 0.65 (§3.3); pairwise similarity of directions from the three EM fine-tunes exceeds 0.8 except for 4 layers (§3.5).
    • Importance filtering: Without a token importance threshold, the authors state regression coefficients have no clear interpretation; adding L1 penalty yields similar division of labor (Appendix G, Figure 17).
    • Coherence threshold: Figure 18's caption states that raising the minimum coherency reduces the medical group's proportion of medical answers, with smaller impact on the medical-aligned combination; specific proportions are not retained.
    • Self-correction: Figure 5 and Appendix E discuss answers that mention harmful content after steering and then turn aligned; the text does not report frequency, with the authors only suggesting a possible link to refusal circuits.
  5. What are some points that can be further explored?

    The authors propose extending the model and evaluation, and continue to analyze downstream convergence, self-correction, and domain filtering mechanisms.

    The authors treat existing results as a starting point for mechanistic research and explicitly propose expanding the verification scope.

    Limitations and future directions noted by the authors

    • Model and fine-tuning scaling: results come from a small number of EM fine-tunes of one base model; the authors suggest studying other models, larger LLMs, and full supervised fine-tuning (§6.2).
    • Evaluation and review: the authors suggest expanding the 8 questions to more diverse, deployment-near scenarios, and note that LLM review may reduce the credibility of results (§6.2).
    • Directions in base models: the authors suggest extracting and studying relevant directions already present in aligned base models, exploring uses for monitoring harmful behavior (§6.1).
    • Self-correction and domain filtering: the authors suggest using circuit methods to dissect self-correction, and extending LoRA analysis to understand why data domain filtering did not produce domain-only misalignment (§6.1).
    • Domain directions and downstream mechanisms: the authors suggest distinguishing whether domain misalignment directions are merely combinations of general and semantic directions, and further localizing the downstream convergence mechanisms of B directions and mean-difference directions (§3.3, §3.5, Appendix D).
    • Scalar replacement evidence: the authors call the results ambiguous, requiring re-study with more question pairs; current coverage spans four types of question pairs (Appendix J).

    Experimental coverage

    • Model scope: mechanistic analysis centers on multiple LoRA fine-tunes of Qwen2.5-14B-Instruct; Qwen2.5-Coder-32B-Instruct is used for unsafe-code model comparison (§2).
    • Transfer scope: directions from the medical-9 adapter model transfer to medical and sports all-adapter fine-tunes on the same base model (§3.4), not cross-base-model transfer.
    • Judgment scope: both behavioral and semantic scoring are done by GPT-4o; Table 1 reports 100 regressions, and the paper does not report generation sample sizes, repetition counts, or human agreement for behavioral experiments (Appendices G, K).
    • Threshold differences: adapter interventions use coherency≥25; the main EM definition is coherency>50, and Figure 18 additionally shows minimum coherence threshold variation (§2, Appendix I).
    • Data and parameter disclosure: Appendix B states the two fine-tuning datasets were generated by GPT-4o; the paper does not report their size, full training hyperparameters, or the high-importance token filtering threshold.
  6. Summarize the main content of the paper

    The authors study shared EM representations via activation and LoRA intervention, while leaving room for multidimensional mechanisms.

    This is a mechanistic analysis of emergent misalignment: the authors study how cross-domain harmful behavior after narrow fine-tuning is carried by internal model representations.

    • Model and method: Build models with 9 medical rank-1 adapters on Qwen2.5-14B-Instruct, extract directions from the mean activation difference between aligned/misaligned answers, then analyze mechanisms with scalar probes, adapter intervention, and scalar replacement.
    • Same-model intervention: After layer-wise ablation of the medical 9-adapter model, EM drops from 11.25% to 0%; ablating all layers with the layer-24 direction yields 1% (§3.4). This adds behavioral intervention evidence beyond merely comparing activation similarity.
    • Same-base-model transfer: When this direction is applied to medical and sports all-adapter fine-tunes, the authors report EM reductions of 90% and 78%, respectively, with coherence exceeding 99% after ablation (§3.4, Figure 4).
    • Direction vs. effect distinction: The layer-24 single-adapter B direction has only 0.04 similarity to the mean-difference direction, yet after full-layer ablation of the mean difference, that model's EM drops from 17% to 0.25% (Appendix D); the authors note that downstream mechanisms still need to be parsed.
    • Adapter division of labor: Medical alignment/misalignment probe Accuracy is 0.69 (Table 1); intervening on the general adapter group produces 52% misaligned answers with no medical content, using coherency ≥ 25 (Figure 7, Appendix I).
    • Authors' conclusion and boundaries: The authors conclude that different EM fine-tunes converge to intervenable linear representations, but do not rule out multidimensional mechanisms. The conclusions rest mainly on one base model and 8 evaluation questions; the authors suggest extending models, fine-tuning methods, and review.

Related papers

Read originalarxiv.org