The paper proposes Conformal Policy Selection, treating the targeted deployment of AI decisions as a multiple testing problem, testing for each candidate individual whether its outcome under the AI policy exceeds a user-specified threshold, and controlling the false discovery rate (FDR) of the selected set. The method combines weighted conformal p-values to handle the distribution shift from the behavior policy to the target policy, along with a two-step screening and pruning procedure. The authors state that they prove finite-sample FDR control and provide doubly robust asymptotic guarantees, i.e., FDR remains controlled when either the outcome model or the propensity model is correctly specified. Synthetic experiments verify these guarantees under four misspecification scenarios; a semi-synthetic study based on real electronic health record covariates shows that the same FDR control can serve as a deployment safety gate, limiting harmful interventions imposed by a globally trained policy when it generalizes incorrectly on high-risk subgroups.
- Even if an AI policy improves outcomes on average, it may still harm some individuals. Decision-makers want to deploy only to people whose outcome under the target policy exceeds a threshold, and to control the expected proportion of selected people who do not exceed the threshold within q.
- Conformal Policy Selection constructs weighted conformal p-values using the likelihood ratio from the behavior policy to the target policy, applies BH to the auxiliary p-values, and then randomly prunes. It gives finite-sample FDR control when the weights are known and the score is monotone; it gives asymptotic control when either the outcome residuals or the weights are correct.
- On synthetic data, across 400 repetitions, WBH's average empirical FDR is below nominal q when at least one of the score or weight is correct; when both are wrong, the average FDR at q=0.15 is 0.287 (Table 1). For the EHR semi-synthetic gating, the harmful deployment proportion is 0 when q≤0.85 (Figure 3).
- In the Discussion, the authors list redefining the nonconformity score and changing the selection target to individual causal effects as future work. The experiments cover four synthetic misspecifications, EHR semi-synthetic gating, LaLonde, and heterogeneous effects in Appendix E; Table 1 reports only WBH. Counterfactuals in the raw EHR are unobservable.