Medical fine-tuning reshapes rather than reduces patient-facing AI risk: an evaluation framework based on a rating scale and LLM judgingMedical Fine-Tuning Reshapes, Not Reduces, Patient-Facing AI Risk: A Rubric-Based, LLM-Judge Evaluation Framework
The authors evaluated six models on K-QA using a risk-language scale, saying medical fine-tuning reshapes rather than reduces overall risk.
- Patient-facing medical question-answering evaluation mainly looks at factual correctness. The authors argue that an answer can be factually grounded and still contain instructions that cause harm if followed, and that the two axes need to be measured separately.
- Defines six categories of risk language, with three cross-family LLM judges assigning severity on a 0–5 anchor, and the response-level risk taken as the maximum. On K-QA, compares three pairs of general and medical models, and uses NLI entailment rate as a factuality proxy.
- On 200 questions, the six-model average RSHS is 1.24–1.43, and the authors state that overall risk does not decrease. Continued pretraining lowers high-alert drugs and raises overconfidence in two pairs; Med42 only lowers dose. At n=300, the Spearman ρ between RSHS and NLI hallucination rate is −0.065.
- The authors state that the two categories have α below 0.4, that the 7–9B panel may not extrapolate to frontier models, that generation is single-seed greedy, and that clinical anchoring validation is still ongoing. The experiments are the six models in Table 2 and 200 K-QA questions; the paper does not report expert agreement numbers.
- Evaluated models
- Mistral-7B-Instruct-v0.3Phi-3.5-miniLlama-3.1-8B-InstructBioMistral-7BOpenBioLLM-Llama3-8BMed42-Llama3-8B
- Benchmarks
- K-QA
- Metrics
- ensemble RSHSNLI hallucination rateSpearman ρdistance correlationKrippendorff α
The researchers propose a risk-sensitive evaluation framework that scores medical question answering by the presence and severity of six categories of risky statements, and evaluate six 7-9B models on 200 real patient questions from K-QA. The framework is anchored in a published clinical harm taxonomy, and a panel of three LLMs judges severity, covering treatment instructions, contraindications, dosing statements, emergency triage advice, high-alert medication mentions, and overconfident assertions. Results show that risky statements and factual hallucination rates are statistically independent of each other (pooled Spearman ρ = -0.065, n = 300). Medical fine-tuning did not reduce overall risk but reshaped its structure: BioMistral and OpenBioLLM adapted by continued pretraining suppress high-alert medication mentions but amplify overconfident assertions; Med42, fine-tuned on clinical instructions, suppresses only dosing statements and does not amplify overconfidence. Krippendorff α is 0.53-0.71 for the four categories based on linguistic features, and only 0.19 and 0.31 for the two categories that depend on clinical judgment.
Paper analysis
What problem does this paper attempt to solve?
Evaluating only factuality is insufficient for patient medical question answering; the authors add six categories of risk language to measure harm if followed.
Factually correct patient-facing medical answers may still contain instructions that could harm a patient who follows them, and existing evaluations mainly measure only factuality.
- Setting: the authors state that patients use LLMs to ask about symptoms, medication, and when to seek care, and that systems are moving from research demos to production deployment. The authors cite clinical literature that the same fact phrased differently changes patient behavior, and that factually correct content can still meet existing criteria for harmful patient communication.
- Gap: the authors state that existing medical LLM evaluations mainly measure factual correctness against reference answers, and thus cover only one axis of safety.
- Hypothesis: the authors consider factuality and potential for harm to be independent dimensions. The second axis is operationalized by the presence and severity of risk language, anchored in Asgari 0–5, the AHRQ Common Format, and the ISMP 2021 high-alert medication list.
- Proposal: six categories of risk language are classified by LLM reviewers according to category anchors, rather than scored with hand-tuned pattern weights. The authors apply this to 200 real patient questions from K-QA and to the three pairs of general/medical models in Table 2.
- Category basis: Table 1 maps each category to a published harm pathway. The authors state that five of the six categories have clinical safety literature; the patient-facing evidence for contraindication is called a research gap by the authors, and the category is retained.
What related research exists?
The authors position the contribution as per-category risk reshaping across three model pairs, and as RSHS being orthogonal to the factuality proxy.
The related work discussion in the introduction is divided into three groups, with no separate Related Work section.
Factuality evaluation
- Pal et al. (2023) Med-HALT, Agarwal et al. (2026) MedHalu, Pandit et al. (2025) MedHallu, Manes et al. (2024) K-QA, Wu et al. (2024): compare against reference answers or detect medical hallucinations. The authors state that prior medical LLM evaluations mainly measured this axis.
- Ji et al. (2023), Zhu et al. (2025): the authors state that the medical hallucination literature has methodological objections to pattern-weight-based risk detection, and respond to those objections with judge classification against reference anchors.
LLM judges and clinical safety scales
- Arora et al. (2025): the authors state that scale-prompted LLM-as-judge can approximate clinician evaluation in adjacent settings. Pombal et al. (2026): the authors cite its documented judge–model-family self-preference as the reason for using cross-family judges.
- Asgari et al. (2025) provides a 0–5 severity scale, on which the authors state this paper's anchors are calibrated. Ayers et al. (2023), Zhang et al. (2023), Lehman et al. (2023), Tam et al. (2024), Kim et al. (2025) use human annotation studies of clinician ratings of LLM safety. AHRQ (2017), ISMP (2021), NCC-MERP (2001) are used as anchors for harm categories and medication errors.
- Diekmann et al. (2025) evaluates agreement between LLMs and clinicians on patient-facing question answering. The authors state that this work does not operationalize harmful language categories as this paper does, nor does it provide per-category reliability analysis.
Medical adaptation and accuracy
- Dorfner et al. (2024), Jeong et al. (2024) characterize the effect of medical adaptation on accuracy. The authors state that this paper builds on that characterization to do per-category risk reshaping, and links RSHS to a factuality proxy.
Baselines and benchmarks
- The comparison is the three pairs of general and medically adapted models in Table 2, not external detectors. Questions come from K-QA; the factuality proxy follows its physician-decomposed must-have claims and NLI entailment judgments. The clinical literature in Table 1 is the basis for the harm pathways of the categories, not a model baseline.
The authors limit claims about "medical fine-tuning" to the models and adaptation procedures studied, and state that three pairs of models cannot answer whether this reshaping generalizes to other adaptation strategies.
How does the paper address this problem?
Six categories of risk language were judged for severity by three reviewers against anchors; response-level risk takes the maximum across categories.
The framework does not judge whether an answer is factually correct; it only makes presence determinations and severity classifications for six categories of risk language; the three-reviewer mean is called ensemble RSHS in §4.
Six categories of risk language
- treatment directive: directed at patients, concerning the starting, stopping, increasing, decreasing, adjusting, switching, combining, or delaying of a specific drug or therapy. Lifestyle advice and general treatment descriptions are excluded.
- contraindication: covers only two named drugs that should not be used together; drug–food, drug–disease, and drug–pregnancy are not in this category. Prohibitions with hedging are counted as low severity.
- dosage expression: patient-facing numerical values plus medical units, dosing frequency, or dose-adjustment instructions. Informational ranges with hedging are counted as low severity.
- urgency triage: escalation or de-escalation of care advice with a timing qualifier. General advice to seek care without a timing qualifier does not count. The authors specify severity asymmetry: missing an emergency counts higher than an unnecessary emergency escalation.
- high alert medication: ISMP 2021 community/ambulatory high-alert medications appearing in an instruction, dosage, contraindication, or interaction context. Purely informational mentions are excluded; aspirin is excluded.
- overconfident assertion: a definitive assertion of diagnosis, prognosis, or reassurance counts as present only if the same sentence or an adjacent sentence contains no acknowledged epistemic hedge. Appendix B gives the detection rules, anchors, drug classes, and hedge list.
Severity and aggregation
Reviewers use the 0–5 ordinal scale of Asgari et al. (2025), mapped to the AHRQ Common Format. Against the anchor classifications for each category at 1, 3, and 5, values between anchors may be given 2 or 4. Appendix B.1 writes 0 as no potential for harm and 5 as life-threatening if followed without supervision. The object is the risk "if the patient follows it," not factual correctness.
Aggregation uses the maximum: OVERALL RISK = max(severity across present categories). The meaning is that answer-level risk takes the highest severity among the categories present, because severity is ordinal and cannot be summed. RISK BREADTH is separately defined as the number of categories present. The main text does not separately give an independent formula for RSHS relative to this maximum.
Three-reviewer ensemble
- The reviewers are Gemini 2.5 Flash, GPT-4o-mini, and Claude Haiku 3.5. The authors state that choosing across families is to mitigate self-preference.
- Each runs independently, temperature 0, with the same scale prompt. Each category outputs present, 0–5 severity, rationale, and trigger span, plus an overall risk.
- The ensemble score is the three-reviewer mean per category. Per-category Krippendorff α is reported in §6. Appendix B.3 requires rating the risk of following the advice rather than factual correctness; the full prompts are in the appendix, and no word lists or syntactic constraints are listed here.
Factuality proxy and model pairs
- NLI hallucination rate is defined as 1 minus entailment rate. The answer is the premise and each must-have claim is the hypothesis. cross-encoder/nli-deberta-v3-small is used; when the entailment logit is higher than the neutral logit, i.e., argmax is entailment, the claim is counted as entailed.
- The six instruction-tuned models are loaded in 4-bit NF4, greedy decoding, seed 42, max new tokens=300, on a single A100, with the same neutral system prompt.
- Table 2: BioMistral is continued pretraining on PMC and PubMed; OpenBioLLM is continued pretraining plus medical SFT; Med42 is full-parameter clinical instruction tuning. Mistral/BioMistral and Llama-3.1/Med42 share base models; Phi-3.5-mini (3.8B) and OpenBioLLM (8B) have different base models. Later in the text the authors still refer to the first two pairs together as continued-pretraining adaptation and to Med42 as clinical instruction tuning.
What experiments did the paper conduct?
On K-QA, the six models' average RSHS ranges from 1.24 to 1.43; the authors state that fine-tuning reshapes categories rather than lowering the overall score.
Experimental Setup
- Models tested: Mistral-7B-Instruct-v0.3, Phi-3.5-mini, Llama-3.1-8B-Instruct, and BioMistral-7B, OpenBioLLM-Llama3-8B, Med42-Llama3-8B. The abstract says 7–9B; Table 2 states Phi-3.5-mini is 3.8B.
- Data: 200 real patient questions from K-QA, covering symptom triage, medication, chronic disease, and post-operative. Of these, 50 have physician-decomposed atomic must-have claims; orthogonality uses these 50, combined n=300.
- Generation: 4-bit NF4, greedy, seed 42, max new tokens=300, single A100, identical neutral system prompt. The paper does not report multiple samples per question.
- Judging: Gemini 2.5 Flash, GPT-4o-mini, Claude Haiku 3.5, temperature 0, per-category mean. Factuality uses cross-encoder/nli-deberta-v3-small.
- Statistics: 95% percentile bootstrap, 5000 resamples for correlations and RSHS, 500 for α. Paired comparisons use Wilcoxon signed-rank; the paper states that combined comparisons use Mann–Whitney U, but the main text does not give U. Tests are two-sided. The 18 paired tests are post-hoc corrected with Bonferroni-Holm and BH (FDR=0.05).
- Metrics: ensemble RSHS, category severity, presence rate, Spearman ρ, distance correlation, Krippendorff α. RISK BREADTH is defined, but the results section gives no summary number.
Main Results
According to Table 4, average ensemble RSHS on the 200 questions:
Swipe horizontally to read the table
Model Type Mean RSHS 95% CI Mistral-7B General 1.43 [1.31, 1.56] Phi-3.5-mini General 1.24 [1.11, 1.38] Llama-3.1-8B General 1.28 [1.14, 1.43] BioMistral-7B Medical 1.41 [1.26, 1.55] OpenBioLLM-Llama3-8B Medical 1.33 [1.19, 1.47] Med42-Llama3-8B Medical 1.25 [1.11, 1.39] - The authors state that the six models fall within [1.24, 1.43], and the table note states they lie within a 0.19 band and that the medical and general groups overlap; they also state that the between-group difference is less than 0.2, and that at the aggregate level medical fine-tuning neither raises nor lowers overall risk.
- The authors state that the category composition differs: the continued-pretraining control lowers actionable risk language and raises overconfidence, while clinical instruction tuning only lowers dosage. The numbers are in Table 5.
- The scatter points in Figure 1 are not readable in plain text; the combined correlation in the caption is the same as in Table 3.
Relationship with NLI hallucination rate
- 50 questions × 6 models, n=300. Combined Spearman ρ=−0.065, p=0.27, 95% bootstrap CI [−0.18, +0.05]. The authors state that this CI bounds |ρ| within 0.18, and that this rules out a practically meaningful correlation in either direction. The abstract describes this result as the two axes being statistically independent.
- Table 3 (each n=50) ρ values are: Mistral-7B −0.135, Phi-3.5-mini +0.274, Llama-3.1-8B −0.184, BioMistral-7B −0.013, OpenBioLLM-Llama3-8B −0.139, Med42-Llama3-8B −0.109. The authors report that none reaches significance after Bonferroni correction; the largest has CI [−0.04, +0.55].
- On the same 300 items, dCor=0.10, 95% CI [0.07, 0.21], independence test p=0.24. The authors state that they therefore could not reject statistical independence between RSHS and NLI hallucination rate. Appendix C gives paired examples of NLI entailment with high RSHS and the reverse; the original responses are not reproduced here.
Category reshaping
According to Table 5, ∆ is the mean severity of medical minus general, with uncorrected p in parentheses, n=200:
Swipe horizontally to read the table
Category Mistral→BioMistral Phi-3.5→OpenBioLLM Llama-3.1→Med42 treatment directive −0.034 (0.49) −0.029 (0.51) +0.032 (0.63) contraindication −0.009 (0.50) +0.005 (1.00) −0.002 (0.91) dosage expression −0.083 (0.07) −0.169 (0.0003) −0.125 (0.013) urgency triage −0.155 (0.005) +0.028 (0.52) −0.020 (0.80) high alert medication −0.154 (p<10−4) −0.086 (0.0004) +0.020 (0.98) overconfident assertion +0.195 (0.008) +0.255 (p<10−4) −0.093 (0.14) - The authors state that BioMistral and OpenBioLLM lower high-alert medication and amplify overconfidence, and each additionally lowers one category (the former urgency, the latter dosage). Med42 only lowers dosage, and its overconfidence ∆ is negative. None of the six cells for treatment directive and contraindication enter the authors' marked suppression or amplification.
- The authors report that under BH (FDR=0.05), 7 of the 18 tests are retained, and state that the headline findings are all among them. The BH p values given: overconfidence amplification is 0.024 and 0.0009; dosage suppression is 0.002 and 0.034; high-alert suppression is 0.0006 and 0.002; urgency suppression is 0.019. The dosage for the Mistral pair is not among these 7.
- The authors interpret the continued-pretraining pattern as a stylistic shift of the biomedical corpus: a confident register replaces patient self-management-style dosage language; and they state that clinical instruction tuning does not produce this shift. Figure 2 does not list the values of each bar in the main text; the authors state that the high-alert medication presence rate for these two pairs is lower than the general controls. The main text states that on the same example, BioMistral's overconfidence score is 2.0 higher than Mistral's; Appendix C has additional paired severity, and the original text is not reproduced here.
Judge agreement
Table 6, n=1,200 (model, response) pairs, three judges. The following are presence α / severity α:
- dosage expression: 0.702 / 0.708
- urgency triage: 0.644 / 0.659
- contraindication: 0.620 / 0.624
- treatment directive: 0.526 / 0.529
- overconfident assertion: 0.269 / 0.305
- high alert medication: 0.186 / 0.193
- OVERALL RISK severity α=0.481; presence not reported
The authors state that the first four categories are fair to good (the abstract says 0.53–0.71; Table 6 severity is 0.529–0.708), and the latter two are low (the abstract says 0.19 and 0.31; table severity is 0.193 and 0.305). The authors state that the composite score is pulled down by the latter two categories. For overconfidence, severity α is higher than presence α; the authors consider that once presence is agreed, severity is relatively consistent, and disagreement is mainly in the detection threshold.
The authors state that the overconfidence amplification in §5 falls on a low-α category, so they treat individual scores as uncertain but the direction as robust: the uncorrected p for the two pairs is ≤0.008, and at least two judges agree in direction for each pair. In §6 the authors state that on the high-confidence RSHS containing only the four categories with α≥0.5, Mistral→BioMistral is −0.172 (p=0.02). Appendix Table 7 reports for the same setting a mean difference of −0.070 (p=0.0076). The two are inconsistent; according to the table, the three pairs are 0.347→0.277 (p=0.0076), 0.255→0.214 (p=0.084), 0.313→0.283 (p=0.985). The authors state that the direction of medical being lower than general holds across the three pairs, that the composite means of the latter two pairs do not reach their test threshold, and that the dosage suppression of the Phi pair is diluted in the composite mean.
Other ablations and analyses
- Table 8, Mistral pair overconfidence severity: Gemini +0.370 (p<0.001), GPT-4o-mini −0.060 (p=0.576), Claude Haiku +0.275 (p=0.009). The table does not restate n.
- Phi pair: Gemini +0.300 (p<0.001), GPT-4o-mini +0.400 (p<0.001), Claude Haiku +0.065 (p=0.416).
- Llama pair: Gemini +0.078 (p=0.278), GPT-4o-mini +0.033 (p=0.505), Claude Haiku −0.389 (p<0.001). The authors state that for the two continued-pretraining pairs at least two judges show amplification, and that the dissenting judge differs by pair; and they consider that Claude's suppression on Med42 may be self-preference.
- Appendix D: orthogonality by single judge is Gemini ρ=−0.089, GPT-4o-mini ρ=−0.079, Claude Haiku ρ=+0.017; the two-judge subset ρ is in [−0.102, −0.034]. The authors state that none reaches p<0.10.
- Exceptions: Med42 overconfidence is not amplified (Table 5, p=0.14), and its high-alert ∆ is positive (p=0.98); the HC-RSHS composite p for Phi and Llama is 0.084 and 0.985.
What are some points that can be further explored?
The authors state that the 7–9B results may not extrapolate to frontier models, and that clinical calibration is still ongoing.
Limitations and future directions noted by the authors
- Two of the six categories have α<0.4; the authors state this is mitigated by reporting by category and by the high-confidence subscale in Appendix D (§7 Limitations).
- The authors state that the 7–9B panel may not generalize to frontier models (§7 Limitations).
- Generation uses greedy decoding with a single seed; the authors state that robustness checks are in Appendix D (§7 Limitations).
- The authors state that LLM reviewer self-preference is mitigated by the three-family ensemble, and that single-reviewer and sub-ensemble results are stable (§7 Limitations, pointing to Appendix D).
- The authors state that clinician anchoring calibration of the scale was still ongoing at camera-ready, and that a validation subset with expert ratings will be reported in a later extension (§7 Limitations).
- Future directions: examine the distribution of confidence markers and dosage strings in the BioMistral and OpenBioLLM training corpora; compare Med42-style instruction tuning with and without hedge-rich patient dialogue; extend the scale to clinician-facing scenarios. The authors state that the framework, prompts, and evaluation code have been released to support these directions (§7 Future work).
Scope of experiments
- The models tested are the six instruction-tuned models in Table 2. Phi-3.5-mini is 3.8B and the rest are 7B or 8B. The three pairs of adaptation are continued pretraining, continued pretraining plus medical SFT, and full-parameter clinical instruction tuning. The questions are 200 from K-QA; orthogonality uses 50 of them, combined n=300.
- Risk scores are given by Gemini 2.5 Flash, GPT-4o-mini, and Claude Haiku 3.5 at temperature 0. Factuality is computed by cross-encoder/nli-deberta-v3-small as argmax entailment.
- The main generation setting is 4-bit NF4, greedy, seed 42, max new tokens=300, a single A100, and the same neutral system prompt. The paper reports no main results outside this setting. §7 states that the single seed has checks in Appendix D; Appendix D gives HC-RSHS and single-reviewer tests, not multi-seed or non-greedy numbers.
- Agreement is Table 6, n=1,200. Appendix D additionally has four-category HC-RSHS (Table 7), single-reviewer Wilcoxon for overconfidence (Table 8), and Spearman for single-reviewer and two-reviewer sub-ensembles.
- The paper reports no agreement numbers between expert ratings and LLM reviewers; the authors state that this subset is left for later. The paper reports no summary numbers for RISK BREADTH and no Mann–Whitney U statistic.
Summarize the main content of the paper
The authors state that medical fine-tuning does not lower the overall K-QA risk score, but rather rewrites the risk composition according to the adaptation method.
The authors do a risk-language evaluation for patient-facing medical question answering, to add an axis beyond factuality.
- Problem: an answer can be factually supported and still contain instructions that could harm a patient who follows them. The authors consider the two axes independent, and existing evaluations mainly measure only factuality.
- Approach: six non-mutually-exclusive categories of risk language, with severity judged by Gemini 2.5 Flash, GPT-4o-mini, and Claude Haiku 3.5 on 0–5 anchors, and answer-level risk taken as the maximum across categories. The models tested are three pairs of general/medical models on K-QA; the factuality proxy is NLI hallucination rate. The abstract says 7–9B, while in Table 2 Phi-3.5-mini is 3.8B.
- Orthogonality: on 50 questions × 6 models (n=300), Spearman ρ between RSHS and NLI hallucination rate is −0.065 (95% CI [−0.18, +0.05]), dCor=0.10 (independence test p=0.24). The abstract writes statistical independence; §4 writes failure to reject independence.
- Reshaping: on 200 questions the six-model mean RSHS is 1.24 to 1.43 (Table 4). The authors state that the aggregate score does not decrease. In Table 5, BioMistral and OpenBioLLM lower high-alert medication severity (∆=−0.154 and −0.086) and raise overconfidence (∆=+0.195 and +0.255); Med42 lowers only dosage (∆=−0.125, p=0.013), with overconfidence p=0.14.
- Agreement: severity α for the four categories with language anchors is 0.529–0.708, and overconfidence and high-alert medication are 0.305 and 0.193 (Table 6). The authors state that automatic evaluation agreement is low for the latter two categories, but the direction of overconfidence amplification is consistent across at least two reviewers.
- Authors' conclusion: in the discussion the authors argue that procurement and red teaming should not look only at factuality scores, nor treat "medical model" as a single category; the adaptation strategy determines which kind of risk gets reshaped. The authors limit this claim to the three model pairs and pipeline studied. The authors also cite Draelos et al. (2026) for an unsafe response rate of 5–13% and a single n=1 case; these are not experiments in this paper.