Skip to content

A decade-scale benchmark evaluating LLMs' ability to identify and follow clinical practice guidelines in multi-turn conversationsA Decade-Scale Benchmark Evaluating LLMs' Clinical Practice Guidelines Detection and Adherence in Multi-turn Conversations

arXiv· arXiv:2603.25196· Andong Tan, Shuyu Dai, Jinglu Wang, Fengtao Zhou, Yan Lu, Xi Wang, Yingcong Chen, Can Yang, Shujie Liu, Hao ChenMedia Computing Group, Microsoft Research Asia; Department of Computer Science and Engineering, Hong Kong University of Science and Technology; School of Computer Science, Peking University; AI Thrust, Information Hub, Hong Kong University of Science and Technology (Guangzhou); Department of Mathematics, Hong Kong University of Science and Technology; Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology; Division of Life Science, Hong Kong University of Science and Technology; HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute, Futian; State Key Laboratory of Nervous System Disorders, Hong Kong University of Science and TechnologyIndexed by this site · 7 days ago· Originally publishedEvaluation

Quick read

Evaluation and benchmarks

Based on the paper PDF (AI-generated); refer to the original

The authors build CPGBench, using multi-turn dialogues generated from 32,155 clinical guideline recommendations to evaluate 8 LLMs; the authors report a detection rate of 71.1%–89.6% while the compliance rate is only 21.8%–63.2%.

Questions
LLMs are entering clinical settings, but there is a lack of large-scale evaluation of whether they can identify and follow clinical practice guidelines (CPGs) in multi-turn dialogue; existing related benchmarks are small in scale, narrow in coverage, and do not test adherence in multi-turn dialogue.
Methods
The authors collected 3,418 CPGs from 9 countries/regions and 2 international organizations, extracted 32,155 recommendations, used DeepSeek-R1 to generate multi-turn dialogues for each, and then used GPT4o as a Judge-LLM to evaluate 8 LLMs on guideline detection, title localization, and adherence.
Experiments and results
The authors report: content detection rate 71.1%–89.6%, title location rate only 3.6%–29.7%, adherence rate 21.8%–63.2%, all lower than the detection rate; adherence rates drop further on the safety-critical subset; human validation with 56 clinicians supports the effectiveness of the automated pipeline.
Limitations and future work
The authors note: errors at each step of the automated pipeline propagate; judging matches involves subjectivity (inter-annotator agreement is imperfect); synthetic dialogues cannot cover all real-world scenarios. The data are not released directly due to redistribution restrictions, and the code has not yet been released.
Experimental setupGPT5、Deepseek-R1 et al. · CPGBench · content detection rate、title grounding rate et al.
Evaluated models
GPT5Deepseek-R1Qwen3-32BGPT4oBaichuan-m2-32BQwen3-4B-instHuatuo-o1-7BLlama3-8B-inst
Benchmarks
CPGBench
Metrics
content detection ratetitle grounding rateadherence rateCohen's kappa
AI summaryResearchers propose an automated benchmark, CPGBench, to evaluate LLMs' ability to identify and follow clinical practice guidelines (CPG) in multi-turn conversations. The benchmark collected 3,418 guideline documents from 9 countries/regions and 2 international organizations over the past decade, covering 24 specialties, and extracted 32,155 clinical recommendations along with information such as issuing body, strength of recommendation and level of evidence; a multi-turn conversation was generated for each recommendation, and 8 mainstream LLMs were tested. Results show that the models' accuracy in identifying recommendations was 71.1%-89.6%, the accuracy of citing the corresponding guideline title was only 3.6%-29.7%, and the adherence rate ranged from 21.8%-63.2%, indicating a clear gap between knowing guideline content and being able to apply it correctly. Manual evaluation involving 56 clinicians from different specialties validated the automated analysis. The authors state that this is the first benchmark to systematically reveal which clinical recommendations LLMs fail to identify or follow in conversations, and emphasize that closing the gap is crucial for the safe deployment of LLMs in real clinical practice.

Researchers propose an automated benchmark, CPGBench, to evaluate LLMs' ability to identify and follow clinical practice guidelines (CPG) in multi-turn conversations. The benchmark collected 3,418 guideline documents from 9 countries/regions and 2 international organizations over the past decade, covering 24 specialties, and extracted 32,155 clinical recommendations along with information such as issuing body, strength of recommendation and level of evidence; a multi-turn conversation was generated for each recommendation, and 8 mainstream LLMs were tested. Results show that the models' accuracy in identifying recommendations was 71.1%-89.6%, the accuracy of citing the corresponding guideline title was only 3.6%-29.7%, and the adherence rate ranged from 21.8%-63.2%, indicating a clear gap between knowing guideline content and being able to apply it correctly. Manual evaluation involving 56 clinicians from different specialties validated the automated analysis. The authors state that this is the first benchmark to systematically reveal which clinical recommendations LLMs fail to identify or follow in conversations, and emphasize that closing the gap is crucial for the safe deployment of LLMs in real clinical practice.

Paper analysis

6 questions; open one to read the full answer

  1. What problem does this paper attempt to solve?

    There is a lack of large-scale benchmarks evaluating the ability of LLMs to identify and follow clinical practice guidelines in multi-turn dialogue.

    Core problem: existing evaluations cannot answer whether LLMs can identify and follow clinical practice guidelines (CPGs) in multi-turn clinical dialogue, a safety-critical capability.

    • Scenario and importance: The authors argue that LLMs are being used for clinical decision support, documentation and patient communication, but produce hallucinations or unsupported statements; CPGs are evidence-based standards set by authoritative bodies, and quantifying how well LLMs follow CPGs is a prerequisite for earning clinical trust, supporting regulation and judging deployment readiness.
    • Shortcomings of existing methods: The authors note that existing evaluations are mostly case studies or small-scale question-answering datasets, covering only a few guideline documents (e.g., only documents published in the UK and US), and do not evaluate in more realistic multi-turn dialogue; manual evaluation of open-ended responses is too costly to exhaustively cover every new model and every new guideline.
    • Core observation: The authors argue that meaningful adherence presupposes that the model has mastered guideline knowledge, so two tasks must be measured together: "detection" (whether it can identify and recall guideline content and give the corresponding title) and "adherence" (whether it can apply the guideline in dialogue).
    • What the paper proposes: CPGBench — an automated large-scale benchmark framework that extracts 32,155 recommendations from 3,418 CPGs and generates a multi-turn dialogue for each, scored automatically by Judge-LLM, supplemented by human validation with 56 clinicians. The authors describe it as the first benchmark that systematically evaluates guideline detection and adherence in multi-turn dialogue across countries/regions and healthcare systems.
  2. What related research exists?

    Existing guideline-related evaluations are small in scale, single-language and single-region, rely on expert-authored questions, and none tests adherence in multi-turn dialogue.

    Small-scale guideline question-answering benchmarks

    • AMEGA (2024) — 135 open-ended questions based on 20 clinical cases, covering NCCN, ACC and AHA guidelines and 13 specialties.
    • PromptGuide (2024) — 34 multiple-choice questions on the strength of evidence for osteoarthritis recommendations (AAOS).
    • ReliaChatGPT (2023) — 25 open-ended questions on 5 hepatobiliary-pancreatic recommendations (NICE, EASL).

    Single-institution or single-disease benchmarks

    • MedGuide (2025) — 7,747 multiple-choice questions generated from US NCCN guidelines, covering 17 cancers and 55 decision trees.
    • SurgicalGuide (2024) — 10 case-judgment questions based on NASS coverage criteria.
    • NICE-RAG (2025) — 70 curated open-ended questions on UK NICE guidelines, with a retrieval corpus of 300 documents.

    Common shortcomings noted by the paper: In Table 2 and the main text, the authors note that these benchmarks are small in scale (few guideline documents, a single language or country, narrow institutional and specialty coverage), do not exhaust all recommendations within any single document, rely on expert-authored questions and expert judgment, and none evaluates guideline adherence in multi-turn dialogue.

    Other related citations

    • HealthBench (2025) — evaluates actual performance in multi-turn clinical interactions; the authors state that the adherence evaluation format of this benchmark follows its approach.
    • Citation reliability studies — Wu et al. (2025, medical domain) and CiteMe (2024, non-medical domain) found that LLM-generated citations are unreliable; the authors cite them as evidence for the low title-location rate.

    Positioning: The authors position CPGBench as the first benchmark spanning a decade, covering 9 countries/regions and all 24 ABMS specialties, with 32,155 multi-turn dialogues, for both detection and adherence, distinguishing it from the above work in scale, coverage and evaluation format.

  3. How does the paper address this problem?

    32,155 recommendations were extracted from 3,418 CPGs, a multi-turn dialogue was generated for each, and Judge-LLM was used to automatically score detection and adherence.

    Overall approach: build the CPGBench automated framework — collect and filter CPG documents, extract structured recommendations, synthesize for each recommendation a multi-turn dialogue that correctly applies it, then transform it into two evaluation inputs, detection and adherence, scored by Judge-LLM against the ground-truth (Fig. 1c, Fig. 7).

    Document collection and filtering

    • Sources: searched with "guideline + country/region", downloaded from the official websites of national health departments, medical societies and international organizations, excluding documents marked as archived; HTML documents were converted to text with Beautifulsoup and PDFs with PymuPDF.
    • Quality filtering: 6,115 documents were collected in total, and GPT4o was used to determine whether each was a high-quality CPG (filtering out consensus statements, position papers, etc.), yielding 4,792; only those published in 2015 or later were kept, giving a final 3,418. The authors state they did not collect directly from PubMed because its guideline labeling criteria are not transparent.

    Structured database construction

    • Information extraction: GPT4o was used to extract from each document all recommendations along with their recommendation strength, level of evidence, applicable context, recommended action, clinical goal, issuing institution, publication date and title (Prompts 4 and 5 in Appendix A), and to classify them by the 24 ABMS specialties (Prompt 6); content exceeding GPT4o's 128K token limit was excluded.
    • Results: 32,155 recommendations were extracted from 3,418 documents; automatic filtering (Prompt 3) additionally produced a subset of 6,632 safety-critical recommendations, defined as recommendations whose omission, delay or incorrect execution could lead to serious harm, permanent disability or death within hours to days.

    Synthetic dialogue generation

    • Generation model: DeepSeek-R1. The authors state that an open-source model was chosen for reproducibility and the largest model for dialogue quality, citing evidence that its medical performance is comparable to closed-source models.
    • Inputs and requirements: The model was given the recommendation text, context, goal, action, title and country, and the dialogue was required to meet five criteria: naturalness, empathy, clinical plausibility, patient plausibility and regional specificity (Prompts 7–9 generate English, German and Chinese dialogues respectively).
    • Format constraints: The output must be a list of user/assistant dictionaries; a <recommendation xxx> marker is inserted where the guideline is applied (validated by regex); the turn before the marked sentence must be a user utterance, ensuring the guideline is applied by the simulated doctor (assistant). Any violation of these constraints triggers regeneration.

    Construction of the detection and adherence tasks

    • Detection: The <recommendation xxx> markers are removed from the dialogue, and the tested LLM is asked to identify the guideline recommendations present in the dialogue and give the corresponding guideline document title (Prompt 10), preventing the model from taking shortcuts via the markers.
    • Adherence: The dialogue is truncated at the turn where the simulated doctor first applies the guideline, deleting that turn and everything after it, yielding a background dialogue ending with a user question, which is fed directly to the tested LLM as the prompt without additional instructions. The authors state this is to avoid the influence of prompt engineering and to test the model's intrinsic adherence ability, following the format of HealthBench.

    Judge-LLM scoring and human validation

    • Scoring: Judge-LLM (GPT4o) compares the model output with the ground-truth recommendation and title used to generate the dialogue, and outputs a 0/1 score plus rationale, evidence snippets and confidence for each of content detection, title location and adherence (Prompts 12–14), re-scoring if the format does not conform; adherence is a binary judgment. Because the generated dialogue may contain additional recommendations, only whether the ground-truth one is hit is judged.
    • Human validation: 56 clinicians participated, evaluating the precision of extracted information (about 3% of documents, 1,160 recommendations), dialogue quality (inclusion, background and non-anomaly rated 0/0.5/1 on 1,500 dialogues), and the agreement between Judge-LLM and humans (75 dialogues × 8 models = 600 responses).
  4. What experiments did the paper conduct?

    8 LLMs on 32,155 recommendations: detection 71.1%–89.6%, title location 3.6%–29.7%, adherence 21.8%–63.2%.

    Experimental setup

    • Tested models: GPT5, DeepSeek-R1 (671B), Qwen3-32B, GPT4o, Baichuan-m2-32B, Qwen3-4B-inst, Huatuo-o1-7B, Llama3-8B-inst, all released between April 2024 and August 2025.
    • Benchmark: CPGBench, 32,155 recommendations extracted from 3,418 CPGs, one multi-turn dialogue per recommendation; plus a subset of 6,632 safety-critical recommendations.
    • Metrics: content detection rate, title location rate, adherence rate (all computed as the number correct divided by the total for the corresponding group); agreement measured with Cohen's kappa.
    • Judging method: Judge-LLM (GPT4o) assigns a 0/1 score against the ground-truth recommendation/title; adherence is binary.
    • Scale: the 8 models produced a total of 514,480 tested responses and 771,720 Judge-LLM analysis outputs; the paper does not report the number of repetitions.
    • Human validation: 56 clinicians; extraction precision evaluated on 1,160 recommendations from 106 documents, dialogue quality on 1,500 dialogues, Judge-LLM agreement on 600 responses.

    Main results

    Overall results on all 32,155 recommendations (Table 1):

    Swipe horizontally to read the table

    ModelContent detectionTitle locationAdherenceAverage
    GPT579.47%29.68%63.18%57.44%
    DeepSeek-R189.62%13.24%50.01%50.96%
    Qwen3-32B84.77%7.96%45.89%46.21%
    GPT4o82.65%7.91%41.75%44.10%
    Baichuan-m2-32B71.13%4.80%49.32%41.75%
    Qwen3-4B-inst72.01%4.17%37.30%37.83%
    Huatuo-o1-7B77.31%3.55%29.50%36.79%
    Llama3-8B-inst79.38%5.33%21.77%35.49%
    • The authors state: GPT5 ranks highest overall; larger models mostly outperform smaller models; no model reaches 100% on any task, and no model leads on all metrics.
    • The authors state: the highest adherence rate (GPT5 63.18%) is lower than the lowest detection rate (Baichuan-m2-32B 71.13%), indicating that recognizing guidelines is easier than applying them correctly.
    • The authors state: strong detection ability does not necessarily imply strong adherence ability — GPT5 has a lower detection rate than DeepSeek-R1, Qwen3-32B and GPT4o but the highest adherence rate; GPT4o has a higher detection rate than Baichuan-m2-32B but a lower adherence rate (82.65% vs 71.13%, 41.75% vs 49.32%).

    Stratified analysis (region and specialty)

    • Differences across regions: Qwen3-4B-inst and Baichuan-m2-32B show larger variance in detection rate across regions (0.0058, 0.0045), while the other models range from 0.0011 (DeepSeek-R1) to 0.0033 (Huatuo-o1-7B) (Fig. 3a).
    • Title location: GPT5 leads in most regions, except on mainland China guidelines; the authors suggest models developed in mainland China may be better optimized for Chinese guidelines. GPT4o, Baichuan-m2-32B, Huatuo-o1-7B and Llama3-8B-inst have a title location rate of 0% on ESNM guidelines; no model exceeds a 60% title location rate in any region/organization (Fig. 3b).
    • Differences across specialties: The variance in detection rate across specialties ranges from 0.0007 (Llama3-8B-inst) to 0.0033 (Qwen3-4B-inst), which the authors describe as small; the association between adherence rate and specialty was p < 1×10⁻⁸ by chi-square test (all models), with adherence rates below 55% for all models in radiology and thoracic surgery, and highest in preventive medicine (above 32% for all models) (Fig. 4a, b).

    Safety-critical subset

    • Overall: On the 6,632 safety-critical recommendations, the model ranking is consistent with the full set; all models have higher detection rates than on the full set (e.g., DeepSeek-R1 93.60%), but all models have lower adherence rates than on the full set (e.g., GPT5 61.25%, Llama3-8B-inst 16.66%, Table 3).
    • Title location: Most models are lower on the safety-critical subset (e.g., GPT5 27.67%, −2.01 percentage points vs the full set), which the authors say suggests a higher likelihood of citation errors in safety-critical scenarios.
    • Specialty differences: On the subset, the variance in detection rate across specialties is higher than on the full set (up to 0.01, DeepSeek-R1), and the gap between detection and adherence is larger in each specialty (Fig. 4c, d).

    Human validation

    • Extraction precision: Recommendation strength scored lowest (94.48% of samples rated 1); recommendation content, context, action and goal were rated at least 0.5 in 97.07%, 96.29%, 96.81% and 96.81% of cases respectively; institution, title and date were rated at least 0.5 in 100% of cases, and title, date and country were rated 1 in 100% of cases (Fig. 6b).
    • Dialogue quality: The proportions rated at least 0.5 on inclusion, background and non-anomaly were 99.86%, 99.86% and 99.73%; however, only 44.3% of non-anomaly ratings were 1, with about 55.5% rated 0.5, which the authors say reflects the limitation of LLMs in simulating fully clinically plausible dialogues (Fig. 6c).
    • Judge-LLM agreement: Cohen's kappa between Judge-LLM and humans for content detection, title location and adherence was 0.84, 0.62 and 0.70 respectively (Fig. 6d); human–human agreement kappa was −0.01 (inclusion), 0.29 (background), 0.72 (non-anomaly), 0.53 (detection), 0.73 (title) and 0.81 (adherence), with the authors explaining the low scores on the first two as due to imbalanced rating distributions (Fig. 6e).

    Other ablations and analyses

    • Adherence to guidelines published after the model's release: clinicians manually checked 20 adherence cases of GPT4o on guidelines published after its release date (2024-05-13), and the authors summarized four causes: the new guideline retains old recommendations, the recommended action does not depend on new knowledge, the model's own social-emotional capabilities, and lenient matching by Judge-LLM.
    • Medical model comparison: Huatuo-o1-7B (fine-tuned from Qwen2.5-7B) has a higher detection rate than the larger Baichuan-m2-32B, which the authors suggest may be because the former was trained on more guideline-related data.
    • Detection–adherence gap: The gap is smallest for GPT5 and Baichuan-m2-32B, and larger for the other models in each specialty (Fig. 5).
  5. What are some points that can be further explored?

    The authors list three limitations: error propagation, subjectivity of judgments, and limited scenario coverage; the data are not directly released, and the code is to be released.

    Limitations and future directions noted by the authors

    • Error propagation (Discussion/Limitations): As with any LLM-based automated pipeline, errors at each step can propagate even with spot checks and clinician audits, introducing noise that may affect the final results.
    • Subjectivity of judgments (Discussion/Limitations): There is ambiguity in judging whether a detected recommendation or title truly matches the ground-truth, and whether a response actually contains a given recommendation, as reflected in imperfect inter-annotator agreement.
    • Scenario coverage (Discussion/Limitations): A recommendation may have countless real-world patient–clinician dialogue scenarios, and synthetic dialogues cannot cover them all; recommendations detected/adhered to in the benchmark may fail in other scenarios, while recommendations not detected/adhered to establish at least one failure scenario and can serve as a pre-deployment risk signal.
    • Data and code release (Data/Code Availability): Because most healthcare institutions restrict redistribution, the data are not released directly; the authors will release the document download, filtering and processing code; the code is in preparation and will be released later.

    Scope of the experiments

    • 8 models were tested, all released between April 2024 and August 2025, including general and medical, open-source and closed-source models (Section 2).
    • The guidelines cover 9 countries/regions and 2 international organizations (WHO, ESNM), in English, German and Chinese, with specialties divided according to the 24 ABMS categories (Table 2, Fig. 1).
    • Dialogues were generated by DeepSeek-R1, document filtering and information extraction used GPT4o, and the Judge-LLM was GPT4o; the paper does not report an ablation swapping the generation or judging model.
    • Human validation: extraction precision was evaluated on 1,160 recommendations from 106 documents, dialogue quality on 1,500 dialogues, Judge-LLM agreement on 600 responses, and human–human agreement was based on 300 dialogues and 150 responses (Section 4.6).
    • The paper does not report the number of repetitions for each model evaluation, nor the sampling parameters of the tested models.
  6. Summarize the main content of the paper

    CPGBench uses 32,155 multi-turn dialogues to test 8 LLMs; the authors report high detection, low adherence, and very weak title localization.

    CPGBench is a large-scale automated benchmark for evaluating the ability of LLMs to detect and follow clinical practice guidelines (CPGs) in multi-turn dialogue.

    • Problem: LLMs are entering clinical settings, but existing guideline-related evaluations are small in scale, narrow in coverage, rely on expert-authored questions, and do not test adherence in multi-turn dialogue; the authors argue that quantifying guideline adherence is a prerequisite for clinical deployment.
    • Method: 3,418 CPGs (published after 2015) were collected from 9 countries/regions and 2 international organizations, 32,155 recommendations were extracted with GPT4o, and a multi-turn dialogue was generated for each with DeepSeek-R1; the detection task requires the model to identify the guideline in the dialogue and give its title, while the adherence task truncates the dialogue before the guideline appears and has the model continue it, with Judge-LLM (GPT4o) assigning 0/1 scores against the ground-truth.
    • Main results (Table 1): content detection rate 71.13%–89.62% (highest for DeepSeek-R1), title location rate only 3.55%–29.68% (highest for GPT5), adherence rate 21.77%–63.18% (highest for GPT5, lowest for Llama3-8B-inst); the highest adherence rate is lower than the lowest detection rate.
    • Safety-critical subset (Table 3): on the 6,632 safety-critical recommendations, all models have higher detection rates but lower adherence rates (GPT5 61.25%, Llama3-8B-inst 16.66%), and the authors state that this gap is amplified in safety-critical scenarios.
    • Human validation: 56 clinicians participated; the proportions rated at least 0.5 on the three dialogue quality metrics all exceed 99.7%, and Cohen's kappa between Judge-LLM and humans is 0.62–0.84.
    • Authors' conclusion: current LLMs are better at recognizing guideline content than at applying it, and the guideline titles they provide are unreliable; the authors argue that at this stage LLMs are better suited as assistive tools than as autonomous decision-making systems, that users should independently verify citations provided by models, and that in safety-critical scenarios they should avoid relying on them as the primary basis.
Read originalarxiv.org