Privacy-preserving thermal human sensing: from Indoor RGB-T dataset to real deploymentTowards Privacy-Preserving Thermal Human Perception from Dataset to Deployment

arXiv· arXiv:2610.14846· Kailai Sun, Yue Cui, Xinwei Wang, Zijie Gao, Baoshen Guo, Zhiqing Hong, Irfan Qaisar, Xu Yang, Yueting Li, Dian Fan, Qianchuan ZhaoUrban Mobility Lab, Massachusetts Institute of Technology; Singapore-MIT Alliance for Research and Technology Centre (SMART), Massachusetts Institute of Technology; Chongqing General Hospital, Chongqing University; Hong Kong Xsmart Century Technology Co., Ltd.; NUS-ISS, National University of Singapore; Information Hub, The Hong Kong University of Science and Technology (Guangzhou); Center for Intelligent and Networked Systems, Department of Automation, BNRist, Tsinghua UniversityIndexed by this site · 2026-10-14· Originally publishedAI updates

Quick read

Evaluation and benchmarks

Based on the paper PDF (AI-generated); refer to the original

The authors construct Indoor RGB-T, with unseen-room YOLO26 detection mAP50 of 0.751 and Swin-S crowd counting accuracy of 0.847.

Questions
Deploying RGB in private spaces such as bedrooms raises privacy concerns. The authors state that alternative modalities like Wi-Fi and radar have coarse resolution and limited semantics, while existing RGB–thermal data is mainly outdoors; indoor thermal crossover and native 80×62 thermal images for human state, crowd counting, and bidirectional translation lack systematic evaluation.
Methods
The authors collected Indoor RGB-T from 20 bedrooms, keeping thermal images at native 80×62. They evaluate occupancy detection, four states, and 1/2 occupancy counting with room-based splits, compare RGB-to-thermal and reverse generation, and deploy lightweight detection to an RGB-free edge sleep monitoring device.
Experiments and results
On unseen rooms, YOLO26 detection mAP50 is 0.751, Swin-S occupancy accuracy is 0.847. U-Net's RGB2T temperature MAE is 0.654°C, R2 is 0.923. Among 100 households in Beijing, 96 report satisfactory operation; among 1,000 commercial units, 30 report thermal sensing issues.
Limitations and future work
The authors write that it can be extended to medical and assisted living scenarios and believe temporal modeling could improve robustness under ambiguous thermal observations. The conclusion lists environmental thermal interference, sensing range, and multi-person occlusion as future directions. The paper does not report repetitions.
Experimental setupFaster R-CNN、RTMDet et al. · Indoor RGB-T · mAP50、mAP50:95 et al.
Evaluated models
Faster R-CNNRTMDetDINOYOLO11RT-DETRYOLO26ResNet18ConvNeXt-TConvNeXt-SSwin-TSwin-SViT-B/16DINOv2 ViT-SPix2PixThermalGANPalette DDPMU-NetNAFNetControlNet-SDXLControlNetBBDM
Benchmarks
Indoor RGB-T
Metrics
mAP50mAP50:95Macro F1AccuracyBAccROC-AUCMAER2PSNRFID
AI summaryThe research team releases the Indoor RGB-T large-scale paired RGB-thermal dataset and completes deployment in a commercial sleep monitoring system. The dataset contains 90,576 thermal frames and 115,557 human bounding box annotations, achieving 0.75 mAP for occupancy detection in unseen rooms and 0.847 accuracy for occupancy estimation. The model was field-tested with 100 participants and deployed on approximately 1,000 devices; the authors note challenges such as environmental thermal interference and multi-person occlusion.

The research team releases the Indoor RGB-T large-scale paired RGB-thermal dataset and completes deployment in a commercial sleep monitoring system. The dataset contains 90,576 thermal frames and 115,557 human bounding box annotations, achieving 0.75 mAP for occupancy detection in unseen rooms and 0.847 accuracy for occupancy estimation. The model was field-tested with 100 participants and deployed on approximately 1,000 devices; the authors note challenges such as environmental thermal interference and multi-person occlusion.

Paper analysis

6 questions; open one to read the full answer

  1. What problem does this paper attempt to solve?

    Private indoor settings lack low-resolution thermal paired data; the authors use Indoor RGB-T for unseen room sensing and deployment.

    Large-scale low-resolution thermal paired data is lacking in private indoor settings, and there is also a lack of systematic evaluation of human state, occupancy, and cross-modal translation on native 80×62 thermal images in unseen rooms.

    • Scenario: The authors consider indoor human sensing as foundational for smart homes, ambient intelligence, medical monitoring, and human-centered automation; deploying RGB in private spaces like bedrooms and hospital rooms raises privacy concerns. The authors also state that Wi-Fi, LiDAR, millimeter-wave radar, Bluetooth, and passive infrared are more privacy-preserving but have coarse spatial resolution and limited semantic information.
    • Existing gaps: The authors state that existing RGB–thermal data and benchmarks mainly target outdoor pedestrian detection, surveillance, and autonomous driving, with limited indoor paired data. Indoor human body temperature can be close to beds, bedding, and heat-emitting devices, creating thermal crossover, compounded by the low resolution of compact thermal cameras, making sensing difficult.
    • Gap: The authors state that whether modern vision models can directly extract location, state, and occupancy from native low-resolution thermal images across unseen indoor scenes has not been systematically evaluated. Under the same indoor conditions, bidirectional translation evaluation of RGB-to-thermal and thermal-to-RGB is also scarce; the authors state that the information to be inferred in the two directions is not the same.
    • Contribution: The authors release Indoor RGB-T, covering 20 bedrooms, with 90,576 frames of 80×62 thermal images, 87,016 time-matched RGB–thermal pairs, and 115,557 annotated boxes. On this basis, they establish benchmarks for occupancy detection, state recognition, occupancy counting, and bidirectional translation, and deploy the thermal sensing model to a commercial sleep monitoring system.
  2. What related research exists?

    Related work covers outdoor and indoor RGB–thermal data, privacy-aware thermal perception, and deployment; the authors state that paired bedroom data remains limited.

    Section 2 of the paper divides related work into datasets, privacy-preserving thermal sensing, and system deployment. The authors position this paper on bedroom-scale native low-resolution paired data, a direct thermal sensing benchmark, and real deployment.

    RGB–thermal datasets

    • Outdoor tasks: KAIST [21] and LLVIP [22] target pedestrian detection in urban traffic, M3FD [23] and MFNet [24] extend to multi-class detection and semantic segmentation; LasHeR [25] and RGBDT500 [26] target multimodal tracking. The thermal resolutions listed in Table I range from 320×256 to 1920×1080, and sample sizes range from 1.5k for MFNet to 734.8k for LasHeR.
    • Indoor data: Thermal-IM [27] performs activity recognition in 2 rooms (288×384, 783 clips); AAU RGB-D-T [28] performs human segmentation in 3 indoor scenes (640×480, 11k). Tri-modal [38] and RGB-D-T Facial [39] each correspond to 1 room. DarkAct [37] contains both indoor and outdoor action data.
    • Authors' comparison: The authors state that indoor, especially bedroom, RGB–thermal data remain limited due to privacy concerns. Table I labels Indoor RGB-T as 20 rooms, 80×62, with boxes, status, person count and thermal interference labels; the table writes the sample size as 87k frames, while the main text and Table II give the number of pairs as 87,016.

    Privacy-preserving thermal human sensing

    • Visible light and depth: The authors review the use of RGB cameras and depth sensors in occupancy detection, pose estimation and activity understanding [30], [31].
    • Thermal route: The authors state that thermal imaging records infrared radiation and can perform human sensing while reducing exposure of identifiable appearance; existing work covers occupancy detection, activity recognition, person counting and indoor environmental control [15], [33], as well as localization, pose and Re-ID on low-resolution thermal arrays.
    • Authors' statement: High-resolution visual sensing remains difficult for privacy-sensitive applications, hence the turn to compact, low-resolution thermal sensing (Section II-B). This section does not single out any one method as a failure.

    System deployment

    • Deployment-oriented evaluation: The work cited by the authors emphasizes cost, computational efficiency, privacy data and robustness under environmental change [34], as well as thermal sensing and edge inference [35].
    • Low-resolution arrays: The authors state that low-resolution thermal arrays with lightweight models can reduce hardware and computational requirements [36]; moving from the lab to real deployment still requires validation in diverse unseen scenes and improvement based on deployment feedback.

    Baseline methods and benchmark

    • Baselines: Detection uses Faster R-CNN, RTMDet, DINO, YOLO11, RT-DETR, YOLO26; person counting uses ResNet18, ConvNeXt-T/S, Swin-T/S, ViT-B/16, DINOv2 ViT-S; RGB-to-thermal uses U-Net, Pix2Pix, ThermalGAN, Palette DDPM; thermal-to-RGB uses Pix2Pix, NAFNet, ControlNet, ControlNet-SDXL, BBDM.
    • Benchmark: Experiments are conducted on the authors' own Indoor RGB-T, with room-disjoint splits for thermal sensing, and no scores are reported on the existing outdoor datasets in Table I.

    The authors state the distinction as: providing native 80×62 paired data in bedrooms, performing status and person-count sensing directly from thermal images, evaluating bidirectional translation on indoor paired data, and deploying the model to a commercial sleep monitoring system.

  3. How does the paper address this problem?

    Evaluate native 80×62 thermal sensing and bidirectional translation with room-disjoint splits, and deploy to RGB-free edge devices.

    The authors construct a paired dataset Indoor RGB-T, feeding only native thermal images into detection and classification, additionally evaluating bidirectional translation on paired observations, and then deploying lightweight detection on an edge sleep monitoring device.

    Data Collection and Annotation

    • Device and timing: RGB and thermal imaging are housed in the same enclosure with fixed relative pose. The thermal imager is a Meridian Innovation MI0802M7G, native 80×62, with diagonal/horizontal/vertical fields of view of 135°, 97°, 73°, module size 9.0×9.0×5.5 mm, recording at approximately 7.3 Hz. RGB is 640×480. Collection took place from June to October 2025, with informed consent from participants.
    • Preserving native resolution: Thermal frames are not spatially upsampled or interpolated; boxes are annotated directly in thermal image coordinates. Each frame contains a 16-bit temperature field, with a pseudo-color rendering for viewing. Temporal matching means a thermal frame has a corresponding RGB frame within 500 ms. Recordings include varying numbers of people and states, acted and spontaneous periods, and heat source disturbances; the paper does not provide frame counts for acted versus spontaneous periods.
    • Four states: Frame-level annotation of the number of people. Localizable people have boxes; location is either on-bed or off-bed, with on-bed further labeled as lying, sitting, or other. The mutually exclusive states are lying, sitting, off-bed, and other. RGB is used only to assist annotation.
    • Scale: 20 bedrooms, 90,576 thermal frames, 86,751 annotated frames, 63,788 RGB images, 87,016 pairs, 115,557 boxes, with an average of 1.33 people per annotated frame (Table II). 3,702 frames lack valid state annotations: 668 frames have no people, 1,192 frames have three or more people with only frame-level counts, 1,519 frames cannot be reliably localized, and 323 frames have boxes but are insufficient to determine one of the four states. After exclusion, 83,049 frames and 110,781 boxes have complete hierarchical annotations. Table II marks some rooms with 9,251 frames without heat source disturbance and 28,357 frames with disturbance; for other rooms this column is empty; the thermal cameras total 28.

    Task Definitions

    • Thermal-only: Occupancy detection localizes people from XT and provides states; state recognition distinguishes the four states; people counting is an image-level binary classification with labels 1 or 2. The authors state that 1–2 people cover the main occupancy patterns in bedrooms.
    • Bidirectional translation: RGB-to-thermal estimates thermal patterns and temperatures, and thermal-to-RGB generates visible appearance. These are written as X̂T=GRT(XR) and X̂R=GTR(XT), respectively denoting estimating the thermal image from RGB and generating RGB from thermal. The authors state that the former must estimate temperatures not present in visible appearance, while the latter must infer visible appearance not present in low-resolution thermal observations.
    • People counting metrics: Both accuracy and balanced accuracy are reported. The latter is the average of recall for the two classes, and the paper provides a binary form composed of TP, FN, TN, and FP.

    Splits, Models, and Training

    • Room-disjoint: Validation rooms are 07, 13, and 20; test rooms are 03, 10, and 18; the remaining rooms are for training. The authors state that this avoids leakage from shared environments and temporally adjacent observations. The paper does not provide frame counts for each split.
    • Detectors: Faster R-CNN, RTMDet, DINO, YOLO11, RT-DETR, and YOLO26, initialized with official COCO pretrained weights and fine-tuned on training rooms. Each prediction includes a box and one of the four states. The authors state that large vision models are not suitable for local deployment and are therefore excluded.
    • People counting: ResNet18, ConvNeXt-T, ConvNeXt-S, Swin-T, Swin-S, ViT-B/16, and DINOv2 ViT-S. Aspect ratio is preserved and padded to 224×224. Training runs for 30 epochs with weighted cross-entropy, AdamW, and cosine learning rate; default learning rate is 3×10−4, and 1×10−4 for ViT-B/16. The checkpoint with the highest validation macro F1 is selected. In the test set, 1-person frames account for 63.3% and 2-person frames for 36.7%, so the minority 2-person class ROC-AUC is also reported.
    • Translation settings: RGB-to-thermal uses paired observations from room04–room12, split 7:2 by room for training and testing with random seed 42; the paper does not specify which two rooms are test rooms. 16-bit measurements are converted to Celsius as ground truth. Image-level metrics are computed on a fixed Inferno colormap identical to the ground truth. Thermal-to-RGB maintains 80×62 and spatial correspondence; the paper does not separately state whether its room split is the same as the former.

    Edge Deployment Form

    • Output and downstream: The device processes native 80×62 frames and outputs the number of people, boxes, and occupancy states, for use in people counting, state tracking, and time-in-bed.
    • Data boundary: The product has only a low-resolution thermal camera, no RGB camera. Inference is performed locally on the device, and raw thermal frames remain on the device; only structured results are sent via Wi-Fi to a private cloud.
    • Hardware: RV1126B, 512 MB memory, RKNN framework, FP16. Latency and power consumption are reported in deployment experiments.
  4. What experiments did the paper conduct?

    On unseen rooms, YOLO26 mAP50 is 0.751, Swin-S occupancy accuracy is 0.847, U-Net temperature MAE is 0.654°C.

    Experimental setup

    • Platform: Ubuntu 22.04, AMD EPYC 9754, 1.5 TB memory, 10 NVIDIA L40S (48 GB each), CUDA 12.0, Python 3.10, PyTorch 1.13. Efficiency of perception models is measured on a single GPU with batch size 1.
    • Data and splits: Indoor RGB-T. Thermal sensing test rooms are 03, 10, 18, and validation is 07, 13, 20. The person-counting test set is 63.3% 1-person frames and 36.7% 2-person frames. The paper does not give the total number of test frames or report repetitions.
    • Models tested: Detection: Faster R-CNN, RTMDet, DINO, YOLO11, RT-DETR, YOLO26, with only XT as input. Person counting: ResNet18, ConvNeXt-T/S, Swin-T/S, ViT-B/16, DINOv2 ViT-S. RGB to thermal: U-Net, Pix2Pix, ThermalGAN (also called ThermalGAN-style in the main text), Palette DDPM. Thermal to RGB: Pix2Pix, NAFNet, ControlNet based on Stable Diffusion 1.5, ControlNet-SDXL, BBDM.
    • Translation data: RGB to thermal uses room04–room12, room-level 7:2, seed 42. The paper does not state the room split for thermal to RGB.
    • Metrics: Detection: mAP50, mAP50:95, precision, recall, macro F1, latency, and FPS. Person counting: accuracy, BAcc, per-class precision/recall/F1, 2-person ROC-AUC, and latency. RGB to thermal: MAE, RMSE, R2, PSNR, SSIM, LPIPS. Thermal to RGB additionally has MS-SSIM, ∆E, FID.
    • Evaluation: The paper does not use LLM review or report agreement with human annotation; perception metrics are computed from boxes and labels. Field and commercial use count resident-reported operating conditions and thermal-sensing-related issues.

    Main results

    The abstract writes occupant-state detection in unseen rooms as 0.75 mAP. Table III reports detection metrics on the room-disjoint test set, and YOLO26's mAP50 is 0.751.

    Swipe horizontally to read the table

    MethodmAP50mAP50:95Macro F1FPS
    Faster R-CNN0.7230.4120.64076.7
    RTMDet0.7420.4520.69983.0
    DINO0.6810.4380.63041.0
    YOLO110.7050.4270.692187.3
    RT-DETR0.6920.3930.66885.8
    YOLO260.7510.4800.723171.6
    • The authors state that all six detectors can perform occupancy detection in previously unseen indoor environments; in the table, YOLO26 has the highest mAP50 and macro F1, DINO has the lowest mAP50, and YOLO11 has the highest FPS.
    • The authors state that real-time occupancy detection on low-resolution thermal input is feasible. DINO has the highest single-frame latency, 24.378 ms (Table III).
    • The same detection output contains both boxes and four state classes. Table III is overall detection, and Table IV breaks it down by class.

    State recognition and person counting

    • Four states: Table IV. The authors state that lying and sitting are the easiest, with mAP50 ranges of 0.795–0.897 and 0.764–0.840 respectively; off-bed is 0.680–0.773; other is the hardest, at 0.379–0.562. YOLO26 has the highest sitting and other, at 0.840 and 0.562, with corresponding F1 of 0.779 and 0.589. Faster R-CNN has the highest lying and off-bed, at 0.897 and 0.773. The authors state that other has more diverse appearance and less consistent thermal patterns. Figure 6 shows qualitative examples of the four classes, and the authors state that the predicted boxes can localize the person and mark the state.
    • Person counting: Table V. Swin-S has accuracy 0.847, BAcc 0.843, macro F1 0.838, 2-person recall 0.827, F1 0.799, and ROC-AUC 0.924; 1-person and 2-person F1 are 0.876 and 0.799. The 0.847 in the abstract is the same as this row. The authors state that the two classes perform relatively balanced, and that both convolutional and hierarchical Transformer backbones work on 80×62 input.
    • Exceptions: ConvNeXt-S has 1-person recall 0.893 and 2-person precision 0.804, but 2-person recall drops to 0.754 and macro F1 is 0.828, lower than ConvNeXt-T's 0.829. DINOv2 ViT-S has accuracy 0.702 and ROC-AUC 0.745, the lowest among the seven backbones. The authors consider that larger backbones are not necessarily better, and that general visual representations may not transfer directly to extremely low-resolution thermal input.

    Cross-modal translation

    • RGB to thermal: Table VI. U-Net has MAE 0.654°C, RMSE 0.860°C, R2 0.923, PSNR 26.754, SSIM 0.616, and LPIPS 0.176. ThermalGAN has MAE 0.726°C and LPIPS 0.063; Pix2Pix has MAE 0.753°C and LPIPS 0.068. Palette DDPM has MAE 2.236°C and R2 0.134. The 0.654°C and 0.923 in the abstract are the same as the U-Net row, and the abstract does not name the method. The authors state that temperature error and perceptual similarity are not fully aligned. In Figure 7, the authors state that U-Net is closer to the spatial distribution of the ground-truth temperature field, especially the high-temperature body regions; Pix2Pix and ThermalGAN are visually acceptable but deviate in intensity; Palette preserves coarse structure but does not recover the fine thermal distribution.
    • Thermal to RGB: Table VII. BBDM has PSNR 19.470, SSIM 0.797, MS-SSIM 0.801, LPIPS 0.161, and FID 20.390. Pix2Pix has MAE 0.062, RMSE 0.118, ∆E 6.700, and PSNR 18.590. NAFNet has PSNR 16.030 and FID 65.590. ControlNet-SDXL and ControlNet have PSNR 10.520 and 10.220, and FID 68.790 and 78.280. The authors consider that Pix2Pix is closer in pixels and color, with slightly lower structural and perceptual metrics than BBDM, and state that this T2RGB generation cannot identify personal information.

    Real deployment

    • On-device measurement: Lightweight YOLO-series detection models run on RV1126B. The authors report an optimized single-frame latency of about 40–50 ms; power consumption is about 2.8–3.5 W with all on-device functions enabled. The authors state that continuous bedroom monitoring is still possible in darkness without relying on visible light.
    • Field: From December 2025 to September 2026, 100 households and 100 volunteers in Beijing. The authors report that 96/100 households (96%) were satisfied with operation; 4/100 households (4%) mistook the thermal pattern of vertical radiators for a person out of bed in winter. This failure did not appear in the controlled evaluation. About one month afterward, improvements were made for environmental thermal interference.
    • Commercial: Entered commercial use in June 2026. The abstract writes about 1,000 units, and Section VI writes that 1,000 units were delivered in the first three months, in regions including China, the United States, Singapore, Germany, France, the United Kingdom, Malaysia, and Israel. All 1,000 units collected feedback: 30 reported thermal-sensing-related issues, and 970 did not. Among the 30, 15 (50.0%) were improper placement, 10 (33.3%) were sunlight heating, and 5 (16.7%) were multi-person occlusion. The authors state that these are deployment issues not sufficiently covered by offline benchmarks, and that field and commercial use together support feasibility, operational robustness, and scalability.

    Other ablations and analyses

    The paper has no separate ablation experiments. The following are efficiency data in tables and data distributions given in the main text.

    • Table III: YOLO26 has precision 0.778, the highest of the six models; YOLO11 has recall 0.681, the highest; YOLO11 latency is 5.339 ms, and DINO is 24.378 ms.
    • Table V latency: ResNet18 is 2.79 ms, ConvNeXt-T is 5.03 ms, Swin-S is 15.74 ms. The main text calls the comparison of the latter two median latency.
    • Figure 4 main text: among 110,781 boxes, the median area is 24.6% of the frame (1,219 pixels); 25% of boxes exceed 40.6% of the frame, and 5% are below 5.2%. The median aspect ratio is 0.70, 65.7% are below 1, and the range is 0.18 to 6.5.
    • Figure 4(c) main text: among 83,049 frames, 55,318 frames (66.6%) have 1 person, 27,730 frames (33.4%) have 2 people, and only 1 frame has 3 people.
    • Figure 5 main text: lying and sitting together account for 79.2% of the 110,781 state-annotated boxes, and other accounts for 5.4%. The lying proportion per room is 19.5%–58.6%, and the off-bed proportion is 4.7%–34.1%.
    • Figure 3 main text: 67,606 frames (81.4%) are entirely in bed, and 15,443 frames (18.6%) have at least one person out of bed; the out-of-bed frame proportion per room is 6.7%–36.3%.
  5. What are some points that can be further explored?

    The authors propose extending scenarios and temporal modeling, and list thermal interference, sensing range, and multi-person occlusion as future directions.

    Limitations and future directions noted by the authors

    • More environments: The authors write that although the data covers diverse rooms and human conditions, extending collection to environments such as medical facilities and assisted living could further evaluate generalization (Section VII).
    • Frame-level benchmark: The authors write that the current benchmark is mainly frame-level sensing; temporal modeling of human behavior could improve robustness under ambiguous thermal observations (Section VII).
    • Deployment issues: In the conclusion, the authors list environmental thermal interference, limited sensing range, and multi-person occlusion as future research directions (Section VIII). The abstract and contribution list also state the same set of directions.

    Experimental coverage

    • Data covers 20 indoor bedrooms, thermal images kept at native 80×62, collected from June to October 2025 (Section III).
    • Thermal sensing test rooms are 03, 10, 18; validation rooms are 07, 13, 20; remaining rooms for training (Section IV-B). Detectors: 6; occupancy counting backbones: 7; efficiency measured on a single GPU, batch size 1 (Section V).
    • RGB-to-thermal uses room04–room12, split 7:2 by room, seed 42; the paper does not state whether thermal-to-RGB uses the same split, nor the frame counts for each split (Section V-C).
    • Field deployment is 100 households in Beijing, from December 2025 to September 2026; commercial deployment starts June 2026, with 1,000 units delivered in the first three months (Section VI).
    • The paper does not report repetitions or statistical significance tests. Occupancy counting labels are only 1 and 2 persons; 1,192 frames with three or more persons retain only frame-level counts (Section III-C, IV-A). The authors state that large vision models are unsuitable for local deployment, so such methods are not included in the detection benchmark (Section V-B).
  6. Summarize the main content of the paper

    Indoor RGB-T supports low-resolution thermal sensing and translation in unseen bedrooms and connects to commercial sleep monitoring deployment.

    Indoor RGB-T is a paired RGB–thermal dataset and multitask benchmark for bedrooms, and connects to a commercial sleep-monitoring device without an RGB camera.

    • Problem: The authors consider RGB unsuitable for deployment in private indoor spaces, while modalities such as Wi-Fi and radar are coarse in space and semantics. Outdoor thermal data cannot directly represent indoor thermal crossover, and native 80×62 thermal images also lack systematic evaluation of position, state, occupant count, and bidirectional translation in unseen rooms.
    • Data and protocol: 20 bedrooms were collected from June to October 2025, retaining the thermal native resolution. The scale is 90,576 thermal frames, 87,016 pairs, and 115,557 boxes; the mutually exclusive states are lying, sitting, other, off-bed. Thermal sensing is split by room, with test rooms 03, 10, 18. Detectors are fine-tuned from COCO weights and output boxes and states; occupant-count estimation distinguishes only 1 person and 2 people.
    • Perception results: The abstract writes that occupant-state detection mAP is 0.75; in Table III, YOLO26's mAP50 is 0.751, mAP50:95 is 0.480, and macro F1 is 0.723. The other class remains the hardest, with mAP50 of 0.379–0.562 (Table IV). Swin-S's occupant-count accuracy is 0.847 and 2-person ROC-AUC is 0.924 (Table V). DINOv2 ViT-S's accuracy is 0.702.
    • Translation and deployment: U-Net's RGB-to-thermal temperature MAE is 0.654°C and R2 is 0.923 (Table VI); Palette DDPM's R2 is 0.134. BBDM's thermal-to-RGB PSNR is 19.470 and FID is 20.390 (Table VII). Of 100 households in Beijing, 96 report satisfactory operation, and 4 show radiator false detections; of 1,000 commercial units, 30 report thermal sensing problems, mainly due to placement, sunlight, and multi-person occlusion.
    • Authors' conclusion: The authors state that native low-resolution thermal images can support occupancy detection, state recognition, and occupant-count estimation in unseen bedrooms, and that field and commercial operation support their practicality. The authors write future directions as more scenes, temporal modeling, and environmental thermal interference, sensing range, and multi-person occlusion.
Read originalarxiv.org