The study reveals unexpected harms of value-aligned LLMs and proposes a context alignment method.Unintended Harms of Value-Aligned LLMs: Psychological and Empirical Insights
The authors report that 154 value-aligned models have a mean maximum toxicity of 0.41 on RealToxicityPrompts (Table 3).
- Personalized models should align with individual values, but the authors argue that some values are associated with harmful information and may bypass safety constraints. This paper examines harmful outputs after alignment to Schwartz values and their relationship to specific safety categories.
- Using VIM, Llama-2 7B is fine-tuned to 154 Schwartz distributions, and compared against instruction fine-tuning and traditional NLP tasks. After scoring on four safety benchmarks, OLS estimates coefficients for value extent and harmful response proportion, then the model is prompted to ignore positively correlated values.
- The 154 value-aligned models have an average maximum toxicity of 0.41 on RealToxicityPrompts, versus 0.35 for untuned (Table 3). On HEx-PHI, prompts that ignore the relevant value reduce the harm scores of value-aligned models (Table 4).
- The authors note that in real scenarios, values related to harmful categories must first be identified, and they plan to extend mitigation strategies. Training, evaluation, and prompting are only in English; the authors plan to expand to other languages and cultures. Experiments use models such as Llama-2 7B, four safety benchmarks, and 154 value distributions.
- Evaluated models
- Llama-2 7BLlama-3.1 8BGemma-2 9BQwen-2.5 7BGemma-3 1BGemma-3 27B
- Benchmarks
- RealToxicityPromptsHolisticBiasRHEx-PHIBeaverTails-EvaluationPVQ40Touché23-ValueEvalEuropean Social Survey
- Metrics
- Expected Maximum ToxicityToxicity ProbabilityNegative rateBias ScoreHarmfulness ScoreHarmfulness Rateunsafe response proportionNMSE
The paper finds that LLMs aligned with personal values are more prone to harmful behavior than un-fine-tuned models, and their risk in traditional safety evaluations is also slightly higher than that of other fine-tuned models. The authors argue that the reason is that such models truly generate text according to the aligned values, thereby amplifying harmful outcomes; using a dataset with fine-grained safety categories, they find a significant correlation between value alignment and safety risk, and explain it with psychological hypotheses. The study proposes an in-context alignment method to improve the safety of value-aligned LLMs, and the work has been accepted by ACL 2025.
Paper analysis
What problem does this paper attempt to solve?
The authors investigate whether models aligned to Schwartz values are more likely to be harmful, and which values and categories this relates to.
When personalized alignment is done according to Schwartz values, are models more likely to produce harmful outputs, and which values and safety categories is this related to?
- Use case: The authors state that personalization should make models express individual values. Kang et al. (2023) use Schwartz distributions to represent individuals. The authors argue that some values are associated with harmful information, may spread unacceptable views, or bypass safety protocols.
- Existing gap: The authors state that Yao et al. (2024) link harmful behaviors to Schwartz values, but rarely break down by safety category or describe mechanisms. Ye et al. (2025a, 2025b) look at general safety metrics.
- Authors' hypothesis: Risk arises from the model generating text according to learned values, thereby amplifying harmful outcomes; relevant directions should align with psychological value-behavior results.
- This work: Using VIM, Llama-2 is aligned to 154 distributions, comparing toxicity and bias, then correlating with sub-item risks. The authors also test a prompt that does not explicitly mention safety, only asking the model to ignore values related to risk.
What related research exists?
Related work includes basic human values, personalized alignment, and LLM safety; the authors position this paper on values and specific safety categories.
Basic human values
- Schwartz (2012): Proposes ten universal values and four higher-order groups as criteria for evaluating behavior. The paper selects it because it is cross-cultural, socially oriented, and used by large surveys and multiple AI datasets.
- Values and behavior: Seddig and Davidov (2018) report that power, stimulation, and attitudes toward interpersonal violence are positively correlated, while universalism and safety are negatively correlated. Other work links attitudes toward drug use, delinquency, white-collar crime, and acceptance of legal norms (Bilsky and Hermann, 2016; Goossen et al., 2016; Bilsky et al., 2022; Askew and Ritter, 2023).
Personalized value alignment
- Personas and preferences: PersonaChat (Zhang et al., 2018) maintains character consistency. There is also personalization by preference or dialogue style, and using models to simulate individuals and predict preferences and behavior (Aher et al., 2023).
- Value data and VIM: VALUENET (Qiu et al., 2022) and Touché23-ValueEval (Mirzakhmedova et al., 2024) annotate Schwartz values for dialogue or arguments on social issues. The VIM of Kang et al. (2023) uses personal value distributions to predict behavior and opinions. This paper uses VIM for alignment.
- FULCRA: Yao et al. (2024) examine model behavior and the represented values. The authors state that little discussion there addresses personal values and corresponding safety risks.
LLM safety
- Toxicity and classification evaluation: Early work focused on toxicity and bias (Zhao et al., 2018; Gehman et al., 2020; Smith et al., 2022). hh-rlhf, Anthropic Red Teaming, and BeaverTails moved toward broader safety risks. HEx-PHI, BeaverTails-Evaluation, and SafetyBench evaluate by category.
- Personalization and harm: Deshpande et al. (2023) report that ChatGPT with assigned personas produces more harmful responses than without personas. Zeng et al. (2024) report that humanizing prompts increases jailbreak success rates. The authors state that these discussions focus on prompts and rarely address fine-tuning with personalized data.
- General safety metrics: Ye et al. (2025a, 2025b) examine human values and general safety metrics. The authors state that they do not break these down by specific category and do not provide mechanisms.
Baselines and benchmarks
- Controls: Un-fine-tuned Llama-2, as well as Alpaca, Dolly, Grammar, Samsum, and ICL with value descriptions. Evaluation uses RealToxicityPrompts, HolisticBiasR, HEx-PHI, and BeaverTails-Evaluation. Alignment data is Touché23-ValueEval, and the real distribution comes from the European Social Survey.
The authors state that this paper is the first systematic analysis, from a psychological perspective, of the relationship between individual values and specific safety risks.
How does the paper address this problem?
Using VIM, Llama-2 7B is aligned to 154 distributions, OLS connects values and safety categories, and the model is prompted to ignore relevant values.
The overall approach is to use VIM to align untuned Llama-2 7B to multiple Schwartz distributions, compare with other fine-tuning, then use OLS to link each value to category-specific safety risks, and finally test prompts that ignore the relevant value. The abstract calls this prompt an in-context alignment method; it is not the same approach as the ICL used below as an alignment baseline.
Value Distributions and VIM
- 154 distributions: The 14 extreme distributions rate only one of the ten values as 6 and the rest as 1, or mark only one of the four higher-order groups as important. The other 140 come from the European Social Survey: for each extreme type, the 10 closest are taken using Jensen-Shannon divergence.
- Ten values: achievement, power, hedonism, self-direction, stimulation, security, conformity, tradition, benevolence, universalism. The four groups are openness to change, self-enhancement, conservation, and self-transcendence.
- VIM: First train the model to generate arguments consistent with the target value, then predict its own degree of agreement with value-related statements according to the target distribution. The training text comes from Touché23-ValueEval (Table 1, 8K), consisting of arguments for or against social issues and value labels. The target distribution is not provided at inference time.
- Training settings: All fine-tuning uses LoRA. Appendix F writes learning rate 2×10^−5, 5 epochs, rank 8, alpha 32, dropout 0.1, AdamW. Non-value data are additionally fine-tuned according to Llama's official recipe. Generation settings are T=0.1, top-p 0.75, and at most 64 new tokens.
Comparison Data and Alignment Check
- Three types of data: The classification follows Liu et al. (2024). Instruction fine-tuning is Alpaca (52K) and Dolly (15K); traditional NLP is Grammar (14K, JFLEG and C4_200M) and Samsum (16K). The authors chose grammar correction and dialogue summarization because the inputs and outputs are closer to open generation.
- ICL baseline: The prompt gives the value definition and a target score of 1–6, then asks the model to answer as that person (Figure 6). This is an alignment baseline, not the risk-mitigation prompt in Section 5.
- Whether aligned: PVQ40 is used to infer the value distribution from model responses, compared with the target using NMSE; values are normalized to 0–1 before comparison. The numbers are in Question 4.
Safety Evaluation and Correlation Estimation
- Traditional benchmarks: RealToxicityPrompts takes 3,000 toxic prompts and uses PerspectiveAPI. Maximum toxicity is the highest score among 10 temperature samples per prompt, then averaged; toxicity probability is the proportion with at least one score not below 0.5. HolisticBiasR takes 17,700 prompts with dispreferred demographic terms and uses a regard classifier. Negative rate is the proportion judged negative; bias score is the percentage of minority subgroup subsets whose negative rate is above the overall mean.
- Category-specific benchmarks: HEx-PHI has 330 items, 30 in each of 11 categories. GPT-4o assigns a 1–5 score, the harm score is the mean, and the harm rate is the proportion receiving a full score; the scoring prompts are in Figures 3 and 4. BeaverTails-Evaluation has 700 items in 14 non-mutually-exclusive categories, and GPT-4o marks unsafe responses and reports their proportion; the prompt is in Figure 5.
- Correlation: OLS is performed on the 154 aligned models, with the degree of each value as the independent variable, and the main text writes that the dependent variable is the proportion of harmful responses. Figure 2 reports the regression coefficients; the full heatmap is in Appendix C. The paper does not state the units of the coefficients.
Prompts That Ignore the Relevant Value
- Four levels: input only; safety prompt; value prompt, which asks the model to ignore a relevant value in that situation; and both together. The full prompts are in Table 13.
- Which categories are chosen: The three categories in HEx-PHI with the highest positive correlation with values: Adult content corresponds to self-direction, and Deception and Political campaigning correspond to universalism. For each value, 11 models are selected from the 154.
- Generalization to untuned models: The same four levels are also used for untuned Llama-2, as well as Llama-3.1 8B, Gemma-2 9B, and Qwen-2.5 7B. For the latter three models, 11 responses are generated per strategy using temperature sampling.
What experiments did the paper conduct?
The authors state that 154 aligned models are more likely to be harmful, with a maximum toxicity of 0.41, compared to 0.35 for the unaligned model (Table 3).
Experimental Setup
- Models: The main results are Llama-2 7B and its fine-tuning. The prompt experiments additionally use untuned Llama-3.1 8B, Gemma-2 9B, and Qwen-2.5 7B. Appendix D covers Gemma-3 1B and 27B. GPT-4o serves as judge; the example in Table 12 writes gpt-4o-2024-08-06, while the rest of the main text writes GPT-4o.
- Comparisons: untuned, Alpaca, Dolly, Grammar, Samsum, ICL, and the average of 154 VIM models. The paper does not state whether the ICL row in Table 3 is also averaged over the 154 distributions.
- Data scale: Training data are in Table 1. Safety prompt counts are in Table 2: 3,000, 17,700, 330, 700. The value distributions are 14 extreme distributions plus 140 from the ESS.
- Metrics: maximum toxicity, toxicity probability (threshold 0.5, 10 samples per prompt), negative rate, bias score, HEx-PHI's 1–5 harm score and full-score proportion, and BeaverTails' unsafe proportion. Correlations are OLS coefficients, and Appendix Figures 7 and 8 write N=154.
- Prompt samples: three HEx-PHI categories; 11 aligned models per value. Llama-3.1 8B, Gemma-2 9B, and Qwen-2.5 7B use 11 temperature samples per strategy. The paper does not state how many generations per prompt untuned Llama-2 uses in Table 4.
- Unreported items: agreement between GPT-4o and humans, number of fine-tuning repetitions, and units of the OLS coefficients. The paper does not state whether the generation temperature in Appendix F is used for the 10 samples of RealToxicityPrompts.
Main Results
According to Table 3, the model is Llama-2 7B. The value alignment row is the average of 154 models. Except for that row, each cell is marked p < 0.001. The authors treat higher values as lower safety.
Swipe horizontally to read the table
Training setting Maximum toxicity Toxicity probability Negative rate Bias score Vanilla 0.35 17.02% 7.59% 94.43% Alpaca 0.19 4.89% 15.85% 94.98% Dolly 0.21 5.92% 15.48% 93.75% Grammar 0.20 5.16% 11.66% 92.96% Samsum 0.36 17.61% 22.44% 94.33% ICL 0.35 17.71% 16.31% 96.79% Value alignment mean 0.41 30.93% 18.49% 95.73% - Authors' interpretation: The authors state that value-aligned models are the least or second least safe on each metric, and are more likely to be harmful than untuned. The abstract also states that the risk in traditional evaluations is slightly higher than for other fine-tuned models.
- Not worst in every cell: The least safe on negative rate is Samsum, and on bias score it is ICL, not the value alignment row.
- Other fine-tuning: The authors state that Alpaca, Dolly, and Grammar have lower toxicity than untuned, and Samsum higher than untuned, and state that this is consistent with the observation that fine-tuning on benign data can also be more harmful (Qi et al., 2023).
Values and Safety Categories
- What was measured: On 154 VIM models, OLS coefficients are in Figure 2. The following numbers align with the column names in the figure, and asterisks are p<0.05 or p<0.01 according to the caption. HEx-PHI: Achievement–Adult content is -1.94; Self-direction–Adult content is 2.38; Hedonism for Adult content, Child abuse, Physical harm, and Political campaigning is 1.80, 2.35, 2.34, 2.16; Power for Child abuse, Illegal activity, Physical harm, and Privacy violation is -2.70, -2.21, -2.38, -2.87; Conformity–Political campaigning is 1.97; Universalism for Deception and Political campaigning is 2.45, 3.12; Security–Tailored financial advice is -1.78; Stimulation–Illegal activity is -1.88. BeaverTails: Achievement–Hate speech is -1.17; Power for Discrimination, Hate speech, Terrorism, and Violence is 1.29, 1.50, -1.50, -1.32; Stimulation–Discrimination is 1.05.
- Authors' psychological interpretation: The authors state that these directions are consistent with human studies, for example achievement is negatively correlated with direct violence, hedonism is positively correlated with illegal activity and violence, and power is positively correlated with interpersonal violence. Appendix B continues with conformity, security, self-direction, stimulation, and universalism. The authors state that the relationship between hedonism and self-directed violence still needs consideration; the relationship between universalism and deception still needs study, and they suggest the model may be following the prompt for the greater common good.
- Text–figure inconsistency: Section 4.3.3 states that Power is negatively correlated with deception. In Figure 2(a), the coefficient for Power–Deception is 0.21, with no asterisk. Table 14 has example responses, and the original sentences are not reproduced here.
Prompts That Ignore the Relevant Value
Harm scores of value-aligned Llama-2 on HEx-PHI (Table 4). Relative to Input only, these comparison cells are marked p<0.01 or p<0.001.
Swipe horizontally to read the table
Category Input Safety Value Both Adult content 4.10 2.87 2.45 2.43 Deception 3.43 2.91 2.69 2.54 Political campaigning 3.50 2.87 2.65 2.30 - Untuned Llama-2: Adult content goes from 4.31 to 3.96 with the Value prompt (written as -0.35 in the table). The authors state that the change on aligned models is larger; the table's change for Adult content with the Value prompt is -1.65. In Table 7, for aligned models the Adult content harm rate goes from 56% to 13% with the Value prompt, 15% with Both, and 26% with Safety.
- Three newer models: Most harm scores in Table 5 decrease and carry asterisks. Those without asterisks are Gemma-2 9B Adult content Value prompt 4.15 (written as -0.07 in the table), and Qwen-2.5 7B Adult content Both 4.48 (written as -0.09 in the table).
- Harm rates do not all decrease: In Table 8, Qwen-2.5 7B Adult content Safety prompt is 72% (written as +5%p in the table), and Input is 68%; Both is 71% (+3%p). Llama-3.1 8B has Adult content Both 62% (+2%p), Deception Value prompt 47% (+2%p), and Political campaigning Value prompt 55% (+3%p). The authors still state that harm scores decrease for the three models and three categories; the above cells are not all consistent with this sentence.
Model Scale
Appendix D compares Gemma-3 1B and 27B on HolisticBiasR. VIM uses only 56 distributions. Except for Vanilla, each row has an asterisk; for 27B, the ICL bias score is p<0.05, and the rest are p<0.001 (Table 6).
Swipe horizontally to read the table
Model Setting Negative rate Bias score Gemma-3 1B Vanilla 6.82 92.62 Gemma-3 1B ICL 16.31 93.61 Gemma-3 1B VIM 19.58 96.78 Gemma-3 27B Vanilla 16.77 96.49 Gemma-3 27B ICL 23.78 97.13 Gemma-3 27B VIM 17.98 98.14 - Authors' interpretation: The authors state that larger models are less safe on both negative rate and bias score under untuned and value-aligned settings; the extent to which ICL raises negative statements is more pronounced in larger models; and at each scale both metrics for ICL and VIM are higher than untuned.
- Not fully consistent with that sentence: In Table 6, the VIM negative rate is lower for 27B than for 1B. The bias score is higher for 27B in all three rows.
Other Ablations and Analyses
- Training set toxicity (Figure 9): Among the more than 8K entries in Touché23-ValueEval, 5 have a toxicity score above 50%, and 0 are above 70%. The scale in Table 1 is written as 8K.
- Alignment error: The average NMSE for the 154 VIM models is 0.0759, and for ICL it is 0.1079.
What are some points that can be further explored?
The authors note that relevant values must be identified before real-world use, and that training, evaluation, and prompting are only in English.
Limitations and Future Directions Noted by the Authors
- Identify values first: The authors write that the tested prompts can reduce specific risks by suppressing positively correlated values, but before real-world use, values related to potentially harmful response categories must first be identified (Limitations).
- Extend mitigation: The authors plan to extend this approach and explore broader mitigation strategies based on these findings (Limitations).
- English only: Training, evaluation, and prompting are only in English. The authors write that training in other languages may affect value alignment, and an English orientation may not cover safety standards of different cultures (Limitations).
- Multilingual and cultural: The authors write that they will extend this investigation to multiple languages and cultural contexts (Limitations).
Experimental Coverage
- Models: Generative models are Llama-2 7B, Llama-3.1 8B, Gemma-2 9B, Qwen-2.5 7B, Gemma-3 1B, and Gemma-3 27B. The latter two appear only in Appendix D, evaluated only on HolisticBiasR, with VIM using 56 distributions.
- Benchmarks and evaluation: RealToxicityPrompts 3,000 items, HolisticBiasR 17,700 items, HEx-PHI 330 items, BeaverTails-Evaluation 700 items. Scoring uses PerspectiveAPI, regard classifier, and GPT-4o.
- Value distributions: Main correlation analysis is on VIM models over 154 distributions, including 14 extreme distributions and 140 from ESS; Appendix Figures 7 and 8 report N=154.
- Prompt experiments: HEx-PHI Adult content, Deception, Political campaigning; 11 aligned models per value; three newer unaligned models with 11 temperature samples per strategy.
- Not reported in the paper: Agreement between GPT-4o and human annotations, number of fine-tuning repetitions, and units of OLS coefficients in Figure 2. The main text describes the regression's dependent variable as the proportion of harmful responses.
Summarize the main content of the paper
Value alignment changes harmful tendencies with Schwartz values; the authors state that ignoring the relevant values can reduce some harm scores.
The authors study why LLMs aligned to Schwartz values are more likely to be harmful in safety evaluations, and use prompts to conduct a mitigation experiment that does not directly state safety.
- Approach: VIM aligns Llama-2 7B to 154 distributions, compared with untuned, Alpaca, Dolly, Grammar, Samsum, and ICL. After scoring on four existing safety benchmarks, OLS is used to estimate coefficients between value degree and the proportion of harmful responses.
- Traditional metrics: The 154 aligned models have an average maximum toxicity of 0.41 and toxicity probability of 30.93% on RealToxicityPrompts, versus 0.35 and 17.02% for untuned (Table 3). The authors state that aligned models are more likely to be harmful than untuned. On negative rate, Samsum is 22.44%, higher than the aligned mean of 18.49%.
- Category-specific correlations: The authors state that several directions in Figure 2 are consistent with value–behavior results in psychology. For example, hedonism–child abuse is 2.35 (p<0.01), and universalism–political campaigning is 3.12 (p<0.01). The main text states that Power is negatively correlated with deception, but in Figure 2(a) that coefficient is 0.21.
- Prompts: For aligned Llama-2 on adult content, input only is 4.10, and ignoring self-direction is 2.45 (Table 4, written as -1.65 in the table). The authors state that even without explicitly stating safety requirements, the harm score decreases. In Table 8, Qwen-2.5 7B's harm rate for adult content with the safety prompt is 72% (written as +5%p in the table), and input is 68%.
- Authors' conclusion: The authors argue that the model is generating text according to aligned values, and therefore is more or less sensitive in different safety situations. The authors state that this is the first study to discuss this type of risk and its psychological causes, and recommend that developers and users pay attention to situations requiring caution. The authors also state that the increase in harm is not caused by explicit toxicity in the training set: among more than 8K entries, 5 are above 50%, and 0 are above 70% (Figure 9).