Guardrail erosion in domain fine-tuned LLMs: A paired audit of knowledge-type refusals in biomedical LLMsGuardrail Erosion in Domain Fine-Tuned Large Language Models: A Paired Audit of Knowledge-Centric Abstention in Biomedical LLMs
The authors conduct a paired audit of 25 biomedical fine-tuned models and 11 bases, and state that the median appropriate abstention rate on MedAbstain after fine-tuning drops from 8.3% to 4.2%.
- Biomedical domain fine-tuned models are increasing, and fine-tuning may erode safety guardrails; prior research mostly focused on intent-level refusal, whereas this paper focuses on knowledge-level abstention (whether to abstain when evidence is insufficient).
- The authors paired 25 biomedical fine-tuned models with their 11 base checkpoints, jointly evaluated four dimensions—capability, caution, calibration, and commitment—on MedAbstain and ClinDet-Bench, and performed statistical analysis using paired tests and cohort inference accounting for shared bases.
- The authors report: on MedAbstain, the median appropriate abstention rate fell from 8.3% to 4.2% (21 of 25 pairs declined); accuracy on newly answered questions was 14.98 pp lower than on questions always answered; answer-token commitment rose and calibration worsened; effect direction and magnitude varied greatly across model pairs.
- The authors note: in the manual verification of MedAbstain perturbed questions, only 38 of 49 annotated cases were judged as should-abstain; many models' training data may contain MedQA, posing contamination risk; ClinDet-Bench has only 94 cases; the audit is observational and factors are confounded; the authors plan to conduct controlled fine-tuning experiments and contamination-free benchmarks.
- Evaluated models
- asclepius-llama2-7basclepius-llama2-13bclinicalcamel-70bhuatuogpt-o1-8bhuatuogpt-o1-70bcamel-platypus2-70bcamel-platypus2-13bopenbiollm-8bopenbiollm-70bmmed-llama-3-8bmmed-llama-3-8b-eninsaloe-beta-8baloe-beta-70bmmed-llama-3.1-70bmmed-llama-3.1-70b-mcqajsl-medllama-3-8b-v2med42-v2-8bmed42-v1-70bmed42-v2-70bmeerkat-8bmedgemma-4b-itmedgemma-27b-text-itqcammel-70qcammel-13palmyra-med-70b-32kLlama 2Llama 3Llama 3.1Gemma-3
- Benchmarks
- MedAbstainClinDet-Bench
- Metrics
- appropriate abstention rateinformedness (Youden's J)accuracyECE10normalized entropymean maximum-choice probabilityconfidence AUROC
Researchers audited 25 biomedical domain fine-tuned large language models and 11 paired base checkpoints, evaluating the effect of fine-tuning on knowledge-type refusals on MedAbstain and ClinDet-Bench. The results show that appropriate refusals by base models were already low, with a median of 8.3% on MedAbstain, and fell further to 4.2% after fine-tuning, with declines in 21 of 25 pairs, and the magnitude and direction of change were not consistent across pairs. Prior work mostly focused on value-type refusals; this work focuses on knowledge-type refusals, and the results suggest the need to develop fine-tuning methods that both improve domain capabilities and preserve appropriate caution.
Paper analysis
What problem does this paper attempt to solve?
Whether domain fine-tuning erodes biomedical LLMs' ability to appropriately abstain when evidence is insufficient; the authors answer this with a paired audit.
Core question: whether fine-tuning in the biomedical domain erodes a model's ability to appropriately abstain when evidence is insufficient (knowledge-centric abstention).
- Setting and importance: The number of domain fine-tuned models (especially biomedical) is growing quickly; fine-tuning is low-cost but may bring hard-to-predict behavioral changes; clinically, a model should abstain or request more information when decisive evidence is lacking, and answer only when evidence is sufficient.
- Gaps in existing research: The authors state that prior work on fine-tuning eroding safety guardrails mainly evaluated value-level harmfulness or refusal (value-centric refusal), rather than evidence-sensitive abstention or uncertainty awareness; large-scale studies across architectures, data combinations, and fine-tuning methods remain limited.
- Core observation and hypothesis: The authors define "guardrail erosion" as a decline in benchmark-defined appropriate caution after domain adaptation, and distinguish three dimensions—capability, caution, and calibration—as well as the probabilistic-distribution property of commitment, hypothesizing that fine-tuning may shift these dimensions separately rather than in sync.
- What the paper proposes: A paired audit of 25 biomedical fine-tuned models and their 11 base checkpoints on MedAbstain and ClinDet-Bench, jointly evaluating four dimensions, using item-level paired tests and cohort-level inference accounting for shared bases.
- Nature of the audit: This is an observational audit of publicly released models, involving no attacker; model family, base alignment, parameter count, training data, and optimization scheme are mutually confounded, and the authors explicitly state that these factors limit attribution.
What related research exists?
Related research falls into three categories: fine-tuning eroding safety alignment, abstention behavior benchmarks, and medical safety and uncertainty benchmarks; this paper positions itself as a complement to them.
Fine-tuning erodes safety alignment
- Qi et al. (2024)—found that as few as 10 adversarial fine-tuning samples can substantially harm safety alignment, and that fine-tuning on benign utility-oriented data also produces smaller but non-trivial degradation.
- Yang et al. (2024)—a small-scale malicious fine-tuning set can broadly subvert refusal behavior; Peng et al. (2024)—safety landscape analysis shows that fine-tuning can move a model out of the "safety basin" in parameter space.
- Vishnubhotla et al. (2026)—an audit found that fine-tuning risk depends on the dataset, model, and safety dimension; Betley et al. (2025)—narrow-task training can induce misalignment outside the fine-tuning domain. The authors note that these studies mainly evaluate value-level harmfulness or refusal, rather than evidence-sensitive abstention.
Abstention behavior benchmarks
- Kirichenko et al. (2026)—AbstentionBench evaluates abstention on unanswerable questions across post-training stages and finds that abstention degrades in several reasoning adaptations. The authors state that it is the closest to this paper, and that this paper's contribution is complementary: extending to a paired audit of biomedical domain-adapted models, and jointly evaluating cautiousness and capability, calibration, and commitment under cohort inference.
Medical uncertainty and safety benchmarks
- Machcha et al. (2026)—MedAbstain, which derives four variants from medical multiple-choice questions to measure abstention; Watanabe et al. (2026)—ClinDet-Bench, which uses deterministic clinical scoring rules to evaluate judgment determinability. These two benchmarks are the evaluation tools of this paper.
- Testoni and Calixto (2026)—found that the quality of clinical uncertainty varies with model, specialty, and question type; the authors use this to argue that paired analysis is needed.
Baselines and comparisons: This paper does not propose a new method but audits publicly released model pairs, with no baseline comparison methods; the evaluation benchmarks are MedAbstain (half of MedQA-USMLE, 1,007 questions per variant) and ClinDet-Bench (94 scenarios in the public snapshot).
Author positioning: This paper extends AbstentionBench-style abstention analysis to the biomedical domain, and differs from fine-tuning safety research focused mainly on value-level refusal through its paired design and multi-dimensional joint evaluation.
How does the paper address this problem?
A paired audit of 25 base–fine-tuned model pairs on two benchmarks quantifies behavioral changes before and after fine-tuning across four dimensions: capability, caution, calibration, and commitment.
Overall approach: pair each fine-tuned model with its base checkpoint, evaluate under the same protocol, compute within-pair absolute changes, and then perform statistical inference at the cohort level. The framework is organized around four dimensions: capability, cautiousness, calibration, and commitment.
Benchmarks and model pairs
- MedAbstain (MA): each medical multiple-choice question derives four variants—original/evidence-ablated × with/without abstention option (MA NA, MA A, MA NAP, MA AP); uses half of MedQA-USMLE, 1,007 questions per variant.
- ClinDet-Bench (CD): deterministic clinical scoring rules judging "Met/Not Met/Unable to determine"; evaluates 94 scenarios from public repository commit 1a05c63 (32 Complete, 30 Incomplete-Determinable, 32 Incomplete-Undeterminable); the paper notes that the original ClinDet-Bench reports 188 cases, and this paper targets the smaller public version.
- Model selection: 25 biomedical fine-tuned models and 11 bases, covering four families: Llama 2, Llama 3, Llama 3.1, and Gemma-3; inclusion criteria are checkpoint availability, documented base lineage (partly inferred), and at least partially public fine-tuning recipes. Fine-tuning recipe families include CPT, SFT, RL, DPO, PEFT, and MERGE.
Evaluation protocol
- All models use a unified plain-text completion prompt (not their respective chat templates), ending with "Answer:"; greedy decoding, temperature 0, at most 2,048 output tokens.
- Answers are parsed with a waterfall logic from determinate to indeterminate; unparseable or conflicting outputs are counted as incorrect and not as abstention.
- Probability metrics: take the first answer token position, sum the probabilities of tokens representing each option in the saved top-20 token list and normalize to 1; thus what is measured is normalized confidence relative to candidate answers, not the full output distribution.
- Sensitivity analysis: 9 model pairs whose bases support chat templates are re-tested under their native templates (Appendix A.2.2).
Metric definitions
- For each metric m and condition v, compute the within-pair change Δ mv = mf,v − mb,v (f for fine-tuned, b for base); proportional changes are reported in percentage points (pp).
- Capability: accuracy under conditions with a clinically valid answer. Appropriate cautiousness: MA AP abstention rate, CD Incomplete-Undeterminable "Unable" rate; abstention on MA A or choosing "Unable" on CD Incomplete-Determinable is counted as over-cautiousness.
- Informedness: borrowing Youden's J, JrMA = Ur,AP − Ur,A (similar for CD); a larger J indicates a greater ability to distinguish cases where abstention is appropriate from those where it is not.
- Coverage transition partition: divide MA A questions into four categories: always answered, newly answered, newly abstained, and both abstained; compare the accuracy gap between newly answered questions and always-answered questions; the partition is also transferred to MA NA to measure capability on the same underlying questions.
- Calibration and commitment: on MA NA and CD Complete, compute ECE10 (ten equal-width confidence bins), mean maximum option probability, normalized entropy, AUROC of confidence in distinguishing correct from incorrect, and confidence on questions both answered incorrectly.
Statistical inference
- Five hypotheses: H1 whether cautiousness decreases; H2 whether informedness changes; H3 whether newly answered questions are harder; H4 whether commitment and calibration change; H5 whether capability and cautiousness changes covary and whether effects are heterogeneous.
- Within pairs, use exact McNemar test, Fisher exact test, and paired question bootstrap; at the cohort level, use model pairs as the unit and the two-sided Wilcoxon signed-rank test.
- Multiple testing is corrected with Benjamini–Hochberg (main results across 15 prespecified tests, qBH < 0.05 as significant); because the 25 fine-tuned models come from only 11 bases, a two-stage hierarchical bootstrap is additionally used for base-clustered inference (pcluster); a change is considered robust only if the direction is consistent, qBH < 0.05, and pcluster < 0.05.
What experiments did the paper conduct?
25 model pairs were measured on four dimensions across two benchmarks: median appropriate abstention fell by 3.48 pp, newly answered questions were harder, commitment rose, and effects were highly heterogeneous.
Experimental setup
- Models evaluated: 25 biomedical fine-tuned models and their 11 base checkpoints, covering the Llama 2, Llama 3, Llama 3.1, and Gemma-3 families, including Asclepius-Llama2-7B/13B, ClinicalCamel-70B, HuatuoGPT-o1-8B/70B, Camel-Platypus2-13B/70B, OpenBioLLM-8B/70B, MMed-Llama-3-8B (and EnIns), Aloe-Beta-8B/70B, MMed-Llama-3.1-70B (and MCQA), JSL-MedLlama-3-8B-v2, Med42-v1-70B, Med42-v2-8B/70B, Meerkat-8B, MedGemma-4B-IT, MedGemma-27B-Text-IT, QCamel-13/70, Palmyra-Med-70B-32K (Figure 1, Appendix Tables 3–4).
- Benchmarks and scale: MedAbstain has 1,007 questions per variant (half of MedQA-USMLE); ClinDet-Bench public snapshot has 94 scenarios.
- Metrics: appropriate abstention rate, Youden's J informedness, accuracy, ECE10, normalized entropy, maximum option probability, confidence on shared errors, confidence AUROC; changes are reported in pp.
- Determination method: deterministic parsing rules and scoring rules, no LLM judge; statistical significance is BH-corrected qBH < 0.05 plus base-clustered pcluster < 0.05.
- Protocol: unified completion prompt, greedy decoding, 2,048 token limit; sensitivity analysis under native templates for 9 model pairs whose bases have chat templates.
- Compute: approximately 38 L40S and 28 H100 GPU hours (vLLM).
Main results
According to Section 3 of the main text and Figures 1–5 (values are medians over 25 model pairs, change = fine-tuned − base):
Swipe horizontally to read the table
Metric Condition Median change Significance Appropriate abstention rate MA AP −3.48 pp (8.3%→4.2%) p=0.0038, qBH=0.009, pcluster=0.003 "Unable" rate CD Incomplete-Undeterminable −6.25 pp p=0.061, qBH=0.083, pcluster=0.182 (not robust) Informedness J MA −0.60 pp p=0.034, qBH=0.052, pcluster=0.100 (not significant after correction) Accuracy difference, newly answered vs always answered MA A −14.98 pp p<0.0001, qBH=0.00009, pcluster<0.001 Normalized entropy MA NA −0.191 qBH<0.001, pcluster=0.001 Maximum option probability MA NA +0.127 qBH<0.001, pcluster=0.002 Confidence on shared errors MA NA +0.112 qBH<0.001, pcluster=0.001 ECE10 MA NA +0.040 qBH=0.009, pcluster=0.040 - The authors state that appropriate abstention on MA AP decreases in 21 of 25 pairs and increases in 4, with a median relative decrease of 45.0% (Appendix Figure 6); CD is directionally consistent but inconclusive, and the robust erosion conclusion is limited to MA.
- The authors argue that informedness was already weak as a limitation inherited from the bases, that fine-tuning does not reliably correct it, and that it does not constitute a further established degradation mechanism across families.
- The authors state that the newly answered question effect is the largest and most robust effect in the main hypothesis family, but that it only supports "coverage changes are concentrated on harder questions," not that fine-tuning generally reduced knowledge on these questions.
Capability–cautiousness coupling and heterogeneity (H5)
- What was measured: the within-pair correlation between capability change and cautiousness change, and cross-pair heterogeneity. Results: on MA the correlation is weak and not significant (rP=−0.249, p=0.210, qBH=0.225); on CD it is a significant negative correlation (rP=−0.538, p=0.008, qBH=0.028). 16 pairs show capability up and cautiousness down, 1 pair both up, 3 pairs capability down and cautiousness up, and 5 pairs both down (Figure 5).
- Heterogeneity: cross-pair heterogeneity I² is 96.3% (MA) and 93.4% (CD) for the two benchmarks; exploratory moderators such as recipe family, base alignment, training intensity, and parameter count are all non-significant after correction.
- Authors' interpretation: there is no general trade-off whereby capability gains necessarily sacrifice cautiousness; adaptation effects vary with the base and training process configuration, and the two dimensions change independently.
Sensitivity and robustness analyses
- Native chat templates (Appendix A.2.2, 9 pairs): median change in MA AP abstention is −2.88 pp (decreasing in 7/9 pairs), directionally consistent with the main protocol; the median difference between templates is +0.79 pp, not statistically distinguishable from zero; the authors note that this subset itself does not reach significance and does not represent the full-cohort effect size.
- Parsing failures (Appendix A.2.1): median parsing failure rate on MA AP is 0% for both roles, and cohort results are unchanged after exclusion (−3.48 pp).
- Full-vocabulary rescoring (Appendix A.4, 10 pairs of 4–8B models): the direction of change in commitment on shared errors is unchanged in every pair and the ordering is preserved (Spearman ρ=0.99); normalization inflates the median commitment change by 0.7 points (a median 6.6% deviation relative to the cohort effect of 11.2 points); the authors note that this sub-analysis is insufficient to re-test the effect itself.
Other ablations and analyses
- CD Complete commitment (Section 3.4): mean answer-token confidence +0.185 (qBH=0.018, pcluster=0.035, the only one passing the clustering criterion); entropy −0.307, confidence on shared errors +0.225 (23 estimable pairs), AUROC +0.089 (qBH=0.060, not passing the clustering criterion); ECE10 shows no reliable change.
- Symmetric analysis of new abstentions (Section 3.3): base accuracy on newly abstained questions is 11.47 pp lower than on always-answered questions (p=0.014, qBH=0.023), but pcluster=0.051, just failing the clustering criterion.
- ECE binning sensitivity (Appendix A.3): the median ECE change on MA NA is +0.0399/+0.0378/+0.0345 for 10/15/20 bins respectively, and the conclusion does not depend on the number of bins; Brier and NLL changes are not significant, which the authors regard as inconclusive rather than corroborating.
- Evidence-removal response (Appendix Figure 8): evidence removal reduces the rate of consistently retaining key information by a median of 7.65 pp (base)/10.63 pp (fine-tuned), while abstention rises only 2.88 pp/1.39 pp; none of the 50 estimable roles reaches full compensation (RR=1).
- Negative results: confidence AUROC changes by only −0.015 (qBH=0.508), i.e., no reliable improvement in the ability of confidence to distinguish correct from incorrect; within each coverage partition on MA NA, no fine-tuned vs base accuracy change passes correction (Appendix Figure 9).
What are some points that can be further explored?
The authors list limitations such as benchmark validity, contamination, and sample size, and plan to conduct controlled fine-tuning experiments and contamination-free benchmarks; the experiments cover 25 model pairs and two benchmarks.
Limitations and future directions noted by the authors
- Limited benchmark scope (Section 5): MA uses multiple-choice questions and LLM-generated evidence ablations rather than interactive clinical decision-making; in its manual validation round, only 38 of 49 annotated perturbation cases were judged as should-abstain, so MA AP does not fully reflect real clinical uncertainty.
- Contamination risk (Section 5): The training or fine-tuning data of many evaluated models contain or may contain MedQA, so evaluation on MedQA-derived benchmarks carries contamination risk; public disclosure is incomplete, making a fully contamination-free sensitivity analysis impossible. The authors plan to develop contamination-free benchmarks for further research.
- Small CD sample size (Section 5): CD has only 94 cases (only 32 Incomplete-Undeterminable), limiting the ability to draw significant conclusions.
- Incomplete protocol coverage (Section 5): A unified completion prompt and greedy decoding improve comparability, but decoding sensitivity and publishers' system prompts were not tested; an explicit abstention option may not generalize to open-ended generation; neither benchmark can show whether a model would refer, request information, or escalate in a deployment workflow.
- Approximate probability metrics (Section 5, Appendix A.4): Metrics are reconstructed from the top-20 tokens and normalized, discarding probabilities outside the candidate set; full-vocabulary rescoring shows that normalization inflates the median change in shared-error commitment by 0.7 points.
- Observational audit (Section 5): Model family, base alignment, parameter count, training data, and optimization scheme are mutually confounded; the authors plan a controlled empirical fine-tuning study to conduct a more causal analysis of erosion drivers (Section 4 also proposes three hypotheses to be tested: always-answer-style supervision, side effects of refusal-reduction objectives, and widening confidence margins).
Experimental coverage
- The models tested are 25 publicly released biomedical fine-tuned models and 11 base checkpoints, covering four families, Llama 2/3/3.1 and Gemma-3; recipe families include CPT, SFT, RL, DPO, PEFT, and MERGE (Section 2.1).
- The benchmarks are MedAbstain (1,007 questions per variant) and the ClinDet-Bench public snapshot (94 scenarios); evaluation uses a unified completion prompt and greedy decoding (Section 2.1).
- The native chat template sensitivity analysis covers 9 pairs (only the Llama-3/3.1 Instruct lineage), and the authors note it does not represent full-cohort effect sizes (Appendix A.2.2).
- Full-vocabulary rescoring covers only 10 pairs of 4–8B models (Appendix A.4).
- The paper reports no human evaluation or human consistency review beyond benchmark labels; the manual validation labels for MA are not publicly released at the item level, and the authors state that item-level analysis was not possible (Appendix A.5).
Summarize the main content of the paper
A paired audit of 25 biomedical model pairs shows that after fine-tuning, knowledge-level appropriate abstention declines and commitment rises, and the effects vary across model pairs.
An audit study on the safety side effects of domain fine-tuning: the authors ask whether biomedical fine-tuning erodes models' ability to appropriately abstain when evidence is insufficient (knowledge-level abstention, distinct from the value-level refusal studied previously).
- Method: pair 25 public biomedical fine-tuned models with their 11 base checkpoints, jointly evaluate four dimensions—capability, cautiousness, calibration, and commitment—on MedAbstain (1,007 questions per variant) and ClinDet-Bench (94 scenarios), and perform inference with within-pair paired tests, BH correction, and base-clustered bootstrap.
- Decreased cautiousness: median appropriate abstention rate on MA AP drops from 8.3% to 4.2% (−3.48 pp, decreasing in 21 of 25 pairs, qBH=0.009); CD is directionally consistent but does not pass correction, and the authors state that the robust conclusion is limited to MedAbstain.
- Not due to improved informedness: the change in informedness J is not significant after correction; the authors argue that weak informedness is a limitation inherited from the bases, and that the reduction in abstention is not because models became better at distinguishing answerable from unanswerable.
- Newly answered region is more error-prone: after fine-tuning, accuracy on newly answered questions is 14.98 pp lower than on always-answered questions (MA A, qBH=0.00009), the largest and most robust effect in the main hypothesis family.
- Increased commitment, worse calibration: on MA NA, normalized entropy drops by 0.191, maximum option probability rises by 0.127, confidence on shared errors rises by 0.112, and ECE10 rises by 0.040, while confidence AUROC shows no reliable change—the authors state that models are more confident on the same questions they answer incorrectly, yet are not better at distinguishing correct from incorrect.
- Heterogeneous effects: cross-pair heterogeneity I² reaches 96.3% (MA) and 93.4% (CD), and no moderator passes correction; cautiousness instead rises in 4 pairs.
- Authors' conclusion: biomedical fine-tuning should be evaluated as a multi-dimensional behavioral intervention, and they recommend reporting all four dimensions by paired checkpoint; the authors plan follow-up research at the causal level with controlled fine-tuning experiments and contamination-free benchmarks.