HerHealthEval: Evaluating Large Language Models' Understanding of Multilingual Women's Health CommunicationHerHealthEval: Evaluating Multilingual and Register-Sensitive Understanding of Women's Health Communication
HerHealthEval evaluates women's health understanding: French and Arabic under-triage reaches 0.994, after correction 0.572, 0.558.
- LLM evaluation in medical communication often looks at response quality and assumes user concerns are correctly understood. Women's health expressions are often influenced by stigma, uncertainty, and indirect phrasing; the same concern across different registers and in English, French, and Modern Standard Arabic may be interpreted as different urgency levels, or answered directly even when information is insufficient.
- HerHealthEval fixes cases, gives six forms in English, French, and Modern Standard Arabic: five retain clinical information, the under-specified form deletes details to test clarification. Risk silver labels are derived from English source answers and propagated across languages. Additionally compares zero-shot multilingual model and QLoRA variants, including language-invariant risk re-adaptation.
- Multilingual adaptation achieved under-triage of 0.994 in French and Arabic, corrected to 0.572 and 0.558; the authors state that pre-correction high consistency came from collapsing to routine. Zero-shot English under-triage is 0.718, and post-correction trilingual clarification recall remains 0.000.
- The authors state the scope is three topics, English/French/Modern Standard Arabic, one model family, and limited configurations, inferring it is exploratory and does not establish clinical safety. Future work includes broader settings, clinical adjudication labels, and uncertainty-aware dialogue. The evaluation covers five configurations with 540 items per language, and over-triage and repetition counts are not reported.
- Evaluated models
- Qwen3.5-9B-Instruct (Model 1, zero-shot)Model 2 (structured English QLoRA)Model 3 (English QLoRA with 4× clarification oversampling)M3-ML (Model 4, joint English–French–Arabic QLoRA)M3-ML-RC (Model 5, risk-corrected multilingual re-adaptation)
- Benchmarks
- HerHealthEvalMENSTHealthCareMagic-100kiCliniq-10k
- Metrics
- under-triagerisk accuracyclarification recallcategory accuracyparse_okcross-form consistency
The researchers propose HerHealthEval, a controlled evaluation framework for multilingual understanding in women's health communication, covering English, French, and Modern Standard Arabic. Each clinical case provides six communication forms: normative, clinical, lay, indirect or vague, emotional concern, and deliberately information-insufficient; the first five retain the same clinical information, the last intentionally omits details to test whether the model recognizes the need to ask follow-up. The study evaluates a multilingual instruction model and QLoRA-adapted variants, examining concern classification, risk calibration, clarification behavior, parse compliance, and cross-form consistency. Results show aggregate accuracy and consistency can mask safety-related failures: under language-asymmetric risk supervision, the multilingual adapted model reaches 0.994 under-triage rate in French and Arabic; after re-adaptation with data-derived, language-invariant risk labels, under-triage drops to 0.572 and 0.558 respectively. The paper argues robust multilingual medical evaluation requires explicit testing of register variation, uncertainty handling, and the provenance and invariance of adaptation labels.
Paper analysis
What problem does this paper attempt to solve?
Evaluating multilingual women's health communication, whether models first understand concerns rather than only response quality.
In women's health communication, do models first understand user concerns rather than just generating plausible responses.
- Scenario: The authors believe medical communication evaluation often looks at response quality and assumes concerns are correctly understood. Stigma, uncertainty, limited health literacy, and indirect phrasing change expression; misreading may underestimate urgency or answer directly when clarification should come first.
- Existing gaps: The authors state existing women's health work mainly evaluates factuality, readability, empathy, and safety, and rarely separately tests whether concerns are identified. In multilingual medical QA, the same clinical intent may receive inconsistent advice.
- Observation: The same concern can be written in clinical, lay, indirect, or emotional registers; clinical information is the same, linguistic evidence differs. Under-specified forms deliberately omit details to test whether the model knows to clarify first.
- Approach: The authors propose HerHealthEval, fixing menstrual, PCOS or hormonal, and fertility cases, giving six forms in English, French, and Modern Standard Arabic, with predefined concern, risk, and under-specification identification targets.
- Questions: RQ1 examines robustness of interpretation under register variation; RQ2 examines systematic differences across English, Arabic, and French in interpretation, triage, and clarification; RQ3 examines how English adaptation and trilingual joint adaptation change these behaviors.
What related research exists?
Existing work mostly evaluates answer quality or cross-lingual consistency, lacking matched-register understanding, triage, and clarification objectives.
The authors divide related work into response quality, cross-lingual understanding, and clarification, and place the gap in understanding evaluation under matched registers.
Women's Health LLM Evaluation
- Response quality: Recker et al. (2025) and de Vries et al. (2025) are cited as works evaluating generated responses on factuality, readability, empathy, and safety. The paper does not elaborate on their experimental details.
- Domain dialogue: MenstLLaMA (Adhikary et al., 2025) does menstrual health education generation; Mai (Mughal et al., 2025) does menstrual health dialogue in English and Roman Urdu. Table 1 states both have no matched forms, nor triage or clarification targets.
- Expert scoring: WHBench (Maurya et al., 2026) uses expert safety rubrics to evaluate clinical responses; PCOS and fertility studies (Graça et al., 2026; Chervenak et al., 2023) use clinical author questions or expert judgments on responses. The authors state these paths typically evaluate response quality rather than separately testing concern identification, urgency, and clarification needs; WHBench's rubric does not include clarification targets.
Multilingual and Sociocultural Understanding
- XLingEval: Jin et al. (2024) evaluate correctness, consistency, and verifiability in English, Spanish, Chinese, and Hindi. The authors state considerable cross-lingual response differences are visible.
- Cross-lingual advice: Schlicht et al. (2025) similarly report inconsistent advice for equivalent clinical questions across languages. The paper does not provide further numbers from that study.
- Culture and form: Hershcovich et al. (2022) distinguish linguistic form, cultural knowledge, and communicative goals; Deva et al. (2025) state appropriate reproductive health responses may require local context beyond literal translation. The authors therefore limit their claims to controlled language and register variation, not treating language as a proxy for culture.
Ambiguity and Clarification
- Dialogue capabilities: Testoni and Fernández (2024), Zhang and Choi (2025) treat identifying uncertainty, finding missing information, requesting additional evidence, and clarifying before responding as distinct capabilities, and state these remain difficult for current dialogue systems. The paper does not use them as experimental baselines.
Baselines and Data
- Baseline methods: Zero-shot Qwen3.5-9B-Instruct; structured English QLoRA; that adaptation plus 4x clarification oversampling; joint English–French–Arabic QLoRA (M3-ML); risk-corrected re-adaptation (M3-ML-RC). English risk accuracy is compared against majority class baseline.
- Benchmarks/datasets: Scoring set is HerHealthEval, with 540 matched items per language. Cases come from MENST, and repackaged HealthCareMagic-100k and iCliniq-10k. When reliable mappings exist, concerns are cross-referenced to NHS, NICHD, and fertility supplements CDC guidelines.
- Positioning: The authors believe the gap is not another response benchmark, but testing whether equivalent meaning across registers and languages is still recognized as the same concern, exposing under-triage and degenerate consistency; also using exact match, source provenance, and paraphrase families to rule out adaptation-evaluation leakage.
How does the paper address this problem?
Fix cases and vary register and language, use silver labels to separately measure concern, risk, and clarification, then compare against language-invariant risk re-adaptation.
The authors use HerHealthEval to fix case identity, changing only language and communicative form, thereby separating understanding from response generation. Figure 1 and Figure 2 are schematic diagrams of the framework and construction process respectively; the text states that prediction differences can be attributed to language implementation. Curves or positions in the figures are not visible in the provided text.
Cases, Forms, and Languages
- Six forms: canonical, clinical, layperson, indirect or hedged, emotionally concerned, deliberately under-specified. The first five are subject to meaning preservation constraints; wording and emotion may vary, but clinical evidence and concern categories remain unchanged.
- Under-specified: This form deliberately omits relevant details, serving as a clarification stress test, not as a meaning-preserving paraphrase. Its labels are not clinicians' judgments on whether real patients need clarification.
- Languages: English, French, Modern Standard Arabic. The authors chose MSA over regional dialects for terminology consistency and controlled cross-language comparison.
- Anchor: Each case is first mapped to a canonical clinical concern, and all variants are attached to this anchor.
Sources, Rewriting, and Review
- Sources: PCOS or hormonal, fertility from HealthCareMagic-100k and iCliniq-10k; menstrual health from MENST, preserving source-level paraphrase family relationships. Candidates are categorized by keywords into three classes, and traces of ChatDoctor text replacement are removed.
- Filtering: After removing near-duplicates, myth-only, off-topic, and non-first-person cases, balance by category. When reliable mappings exist, cross-reference NHS, NICHD; fertility supplements CDC; uncertain cases are only marked, not inferred labels.
- Rewriting: Template pilot caused lexical convergence, especially in clinical register, so switched to distinctiveness and semantic preservation checks, then manual review of semantics, register, and naturalness.
- Localization: After standardized LLM-assisted translation, structural and alignment checks, then native speaker review. Arabic additionally undergoes professional Arabic-English medical translation review for terminology, grammar, and gender consistency. Only entries passing manual language validation are retained.
Silver Labels and Leakage Prevention
- Evaluation risk: Deterministic keyword heuristics derive silver labels from English source answers; each English source case is counted once, then propagated by case identity to French and Arabic, so evaluation labels are language-invariant. The paper does not list keywords.
- Clarification labels: Under-specified forms are positive, others negative, shared across languages. It tests injected information gaps, not general clinical clarification standards. Both target types are silver labels, not clinical judgments.
- Failure case: Post-hoc audit found the original multilingual adaptation applied English heuristics directly to translations; lacking English consultation phrases, French and Arabic labels biased toward routine. The authors retain this model M3-ML (Model 4) as a failure case.
- Correction and isolation: M3-ML-RC (Model 5) derives risk only once from English answers, linked to trilingual adaptation rows via row_id, with the rest of the adaptation process unchanged. Evaluation and adaptation are isolated by exact match, source provenance, and paraphrase family rules.
Metrics
- Triage: under-triage is the proportion of see-doctor references labeled routine, denominator is the subset with valid parse and reference see-doctor; over-triage is the opposite error. Risk accuracy is additionally reported with majority class baseline due to class imbalance.
- Others: concern accuracy, clarification recall and specificity, parse_ok, whether six-form labels are identical, and pairwise and three-way agreement across English, French, Arabic. Model self-reported unsafe_response is an auxiliary flag.
- Tests: Paired comparisons on shared items use McNemar; Model 4 and Model 5 are also compared on see-doctor references, avoiding routine as outcome.
What experiments did the paper conduct?
Asymmetric risk supervision led to under-triage of 0.994 in French and Arabic, corrected to 0.572 and 0.558, with clarification recall still 0.
The authors compare Qwen3.5-9B-Instruct zero-shot and four QLoRA variants on HerHealthEval; the main comparison is French and Arabic triage under language-asymmetric risk labels, and whether corrected clarification is restored.
Experimental Setup
- Models: All based on Qwen3.5-9B-Instruct. Model 1 zero-shot; Model 2 English structured QLoRA; Model 3 with 4x oversampling on clarification; Model 4 joint English-French-Arabic QLoRA, i.e., M3-ML; Model 5 is M3-ML-RC.
- Scope: All five evaluated in English; Models 1, 4, 5 additionally evaluated in matched French and Modern Standard Arabic. 540 items per language, sharing case identity and language-invariant silver labels.
- Subsets: The text states English see-doctor reference 174 cases, under-specified cases requiring clarification 90. Topics are menstruation, PCOS or hormones, fertility. The paper does not report counts per category or adapted corpus size.
- Controls: Zero-shot as reference; English risk accuracy additionally compared to majority-class baseline 0.644 (Table 2). Table 3 does not give majority-class baseline.
- Judgment: Compared against predefined silver labels, not LLM review, not clinical adjudication. Risk, category, triage, and clarification count only parse-valid outputs; failures separately recorded as parse_ok.
- Tests: McNemar used on shared items. The paper does not report number of repeated runs, QLoRA rank, or training steps.
Main Results
Below table n=540 per language. English Models 1–4 from Table 2; Model 5 and French/Arabic from Table 3. Overlapping English numbers are consistent. Models 2, 3 have no French/Arabic results, cells marked not reported.
Swipe horizontally to read the table
Model English under-triage French under-triage Arabic under-triage Clarification recall (En/Fr/Ar) Model 1 0.718 0.632 0.638 0.856 / 0.811 / 0.889 Model 2 0.647 not reported not reported 0.044 / not reported / not reported Model 3 0.605 not reported not reported 0.000 / not reported / not reported Model 4 0.711 0.994 0.994 0.000 / 0.000 / 0.011 Model 5 0.590 0.572 0.558 0.000 / 0.000 / 0.000 - Collapse: The authors state Model 4 almost always predicts routine in French and Arabic, about 173/174 see-doctor references labeled lower risk; French-Arabic agreement 0.991, three-way agreement drops from 0.846 to 0.804. The authors call this degenerate agreement, not safety understanding (Section 4.3).
- Correction: The authors state Model 5 under-triage is lower than Model 1, but aggregate risk accuracy underestimates the change because some routine accuracy is traded for see-doctor upgrades. Relative to Model 4, French corrects 74 cases, 1 reverse (p=4.0×10^-21), Arabic corrects 75 cases, 0 reverse (p=5.3×10^-23).
- Clarification: The authors state risk correction does not restore clarification seeking. This recall measures identification of constructed information gaps; the authors state near-zero should not be directly taken as evidence of clinical unsafety.
English Adaptation and Oversampling
- Setup: QLoRA on leakage-controlled corpus, output still uses same structured triage schema. Table 2 compares Model 2, Model 3 with 4x clarification oversampling, and Model 4's English results.
- Numbers: parse_ok for Models 2–4 are 0.998, 0.996, 0.998. English category agreement rises from 0.156 to 0.344, 0.378, 0.411. Model 3 risk accuracy 0.665, under-triage 0.605; Model 2 risk accuracy 0.623, below majority class 0.644.
- Author interpretation: The authors believe 4x oversampling did not restore clarification, mere exposure may be insufficient, clarification may need explicit training objective. Model 2 risk correctness worse than Model 1 (p=0.033), category and clarification correctness p=0.707, 0.302. The authors state Models 3, 4 have no statistical difference from Model 1 in item-wise accuracy, main effects in safety-sensitive and group-level metrics.
Zero-shot Interpretation Differences
- English: Model 1 risk accuracy 0.667, majority-class baseline 0.644. The authors state see-doctor recall about 0.282, routine recall 0.897; clarification specificity 0.862 (Section 4.1, 90 cases).
- Categories and forms: Concern accuracy 0.539, fertility recall 0.467, the authors state fertility hardest. Six-form risk agreement 0.644, concern agreement 0.156 (Table 2). The authors state communicative style substantially affects interpretation.
- Trilingual: Table 3 Model 1 risk accuracy English 0.667, French 0.685, Arabic 0.674, risk agreement 0.644, 0.544, 0.456. Section 4.3 attributes French/Arabic under-triage rising to 0.994 in table to language-asymmetric supervision.
Other Ablations and Analyses
- English risk agreement: Model 1 0.644, Models 2–4 0.433, 0.444, 0.500 (Table 2); Model 5 0.367 (Table 3).
- French/Arabic risk agreement: Model 1 0.544, 0.456, Model 4 0.978, 0.967, Model 5 0.467, 0.422 (Table 3).
- Concern accuracy lowest 0.510 (Table 2, Model 4 English), highest 0.561 (Table 3, Model 1 French).
- Model 4 English category agreement 0.411, higher than Models 2, 3, but the authors state it does not retain Model 3's triage gains (Table 2).
- Model 5 parse_ok English 0.994, French 0.991, Arabic 0.989 (Table 3); Section 4.2 states Models 2–4 not below 0.996, that sentence does not include Model 5.
- The paper does not report over-triage and unsafe_response values, nor Table 3 majority-class baseline.
What are some points that can be further explored?
The authors note the scope is three topics, three languages, and one model family, and results do not establish clinical safety.
In Limitations and Discussion, the authors state the scope, exploratory inferences, and that the results do not establish clinical safety.
Limitations and future directions noted by the authors
- Framework nature: The authors state that HerHealthEval is an evaluation framework, not a fixed-scale benchmark (Limitations).
- Scope: The authors state that this study covers three women's health topics, English, French, Modern Standard Arabic, one multilingual model family, and limited adaptation configurations (Limitations).
- Inference: Matches are treated as independent pairs, without confidence intervals clustered by source case; the authors state that inferential claims should be interpreted as exploratory (Limitations).
- Future work: The authors write that future work will validate in more clinical and language settings, and add clinician adjudication labels and uncertainty-aware dialogue mechanisms (Limitations).
- Safety claims: In Discussion, the authors point out that Model 5 points to the adapted labeling pipeline, not multilingual adaptation itself, but does not establish clinical safety.
- Clarification interpretation: In Discussion, the authors qualify that near-zero clarification recall is a failure to identify injected information gaps, not direct evidence of clinical unsafety.
Experimental coverage
- All five configurations are based on Qwen3.5-9B-Instruct; English n=540 evaluates all, French and Arabic each n=540 evaluate Models 1, 4, and 5 (Section 4, Table 2, Table 3).
- Topics are menstruation, PCOS or hormones, and fertility; six forms per case; the three languages share case identity and language-invariant silver labels (Sections 3 and 4).
- The English text gives see-doctor reference 174 cases, under-specified 90 cases, clarification specificity 0.862, see-doctor recall about 0.282, routine recall 0.897, fertility recall 0.467 (Section 4.1).
- Reported paired tests include three McNemar p-values for Model 2 vs. Model 1, and b, c, and p-values for Model 5 relative to Model 4 on the see-doctor reference (Sections 4.2, 4.3).
- The paper does not report over-triage values, unsafe_response values, adaptation corpus size, QLoRA rank, training steps, number of repetitions, number of reviewers and reviewer agreement, or the majority-class baseline for Table 3.
Summarize the main content of the paper
HerHealthEval separately measures understanding, triage, and clarification under register variants; the authors state aggregate metrics can mask safety-related failures.
HerHealthEval evaluates multilingual, register-sensitive understanding in women's health communication, not just generated responses.
- Need to separately assess whether the model identifies the same concern, labels risk as see-doctor or routine, and asks for clarification when deliberately under-specified. Each case has six forms in English, French, and Modern Standard Arabic.
- Evaluation risk is derived from English source answers and propagated across languages. The adaptation side previously applied English heuristics directly to translations; the authors retain this M3-ML as a failure case, then use language-invariant labels for M3-ML-RC.
- Zero-shot Qwen3.5-9B-Instruct English risk accuracy 0.667, majority class baseline 0.644; under-triage 0.718, clarification recall 0.856 (Table 2, n=540).
- Under language-asymmetric supervision, French and Arabic under-triage 0.994, risk consistency 0.978 and 0.967; the authors state high consistency comes from collapsing to routine (Table 3, Section 4.3).
- After re-adaptation with language-invariant labels, under-triage is French 0.572, Arabic 0.558, English 0.590, and trilingual clarification recall remains 0.000 (Table 3). The authors believe this points to the labeling process and state it does not establish clinical safety.
- The authors state that answers to the three research questions are tentative: aggregate accuracy and consistency may mask safety-relevant failures; multilingual medical evaluation should separately test understanding, uncertainty handling, and risk calibration, and check whether adaptation labels are language-invariant and quality-controlled.