VIAS: Value-Isolated Activation Steering for Organizational Multi-Value Alignment and ComplianceVIAS: Value-Isolating Activation Steering for Multi-Value Alignment and Compliance for Organisations
The authors propose VIAS, which constructs activation steering directions using per-value isolated contrastive samples; on PROTECT, combined with value prompts, it achieves a strict compliance rate of 69.6% on Qwen2.5-7B, higher than 67.4% with prompts alone.
- LLM agents deployed by organizations need to comply with multiple organizational values simultaneously, and prompts alone cannot guarantee compliance; conventional contrastive construction yields steering directions for different values that are nearly collinear, making them hard to control separately.
- For the same scenario, VIAS generates responses using prompts that list all annotated values and that omit a single target value, respectively, and keeps a sample pair only when the target value's judgment changes from compliant to non-compliant and the compliance rate of the remaining values is over half; it then constructs per-value directions by mean difference and merges them with weighting.
- On the 800 PROTECT test scenarios, the strict sample compliance rate of VIAS with values prompts is 69.6% for Qwen2.5-7B, 75.2% for Mistral-7B, and 72.6% for Phi-3.5-mini, all higher than prompting alone; however, the improvement over prompting for Qwen and Mistral does not reach 5% significance under the paired bootstrap test.
- The authors note: the magnitude of improvement varies by model and some are not significant; VIAS depends on scenarios containing at least two values and filtered by reviewers, with uneven coverage of rare values; it covers only three 3.8–7B models and one taxonomy; compliance is scored throughout by an LLM reviewer, and cross-review cannot eliminate the selection bias of the primary reviewer.
- Evaluated models
- Qwen2.5-7B-InstructMistral-7B-Instruct-v0.3Phi-3.5-mini-instruct
- Benchmarks
- PROTECT
- Metrics
- strict sample compliancemicro compliancemacro compliancehard-subset recoverymean coherence
The researchers propose VIAS (Value-Isolated Activation Steering), which increases a model's compliance with organizational values by adding vectors to the model's internal activations at generation time without changing weights. The method contrasts two prompts for the same scenario, one listing all relevant values and the other omitting a single target value, and retains a sample only when the target value changes from compliant to non-compliant while the remaining values still meet the minimum compliance level. The authors note that vectors obtained by directly contrasting compliant and violating responses are nearly identical across different values, capturing a generic compliance signal rather than individual values, which limits their use when combining multiple values. On PROTECT, a workplace compliance dataset containing 21 value categories, VIAS combined with prompting achieved 69.6% for Qwen2.5-7B, 75.2% for Mistral-7B, and 72.6% for Phi-3.5-mini of scenarios satisfying all annotated values, all three outperforming prompting alone. The authors state that VIAS reduces overlap between value vectors, but that this alone does not achieve independent control over each value.
Paper analysis
What problem does this paper attempt to solve?
The authors study whether activation steering can improve an LLM's simultaneous compliance with multiple organizational values beyond prompting.
Core question: can activation steering improve an LLM agent's simultaneous compliance with multiple organizational values without fine-tuning weights, beyond the level achievable with prompts alone.
- Application setting: organizations increasingly deploy LLM agents for employees and external users (customer service, coding assistants, etc.); the authors argue these systems act on behalf of the organization and must follow the organization's code of conduct and values.
- Shortcomings of existing approaches: according to the paper, common approaches are writing values into prompts or building datasets for fine-tuning; prompts cannot guarantee compliance, and the authors want to avoid changing weights. The paper focuses on multi-value settings under the PROTECT taxonomy (21 organizational values).
- Core observation: a simple way to construct steering vectors is to contrast responses that "follow all relevant values" with responses that "violate all values," but the authors find that the vectors obtained this way for different values are nearly identical—they capture a generic "compliant vs. violating" signal rather than individual values, limiting multi-value combination.
- Proposed method: the paper proposes VIAS (Value-Isolating Activation Steering), which for the same scenario generates contrastive responses using two prompts, "list all relevant values" and "omit only one target value," and keeps a sample pair only when the target value's judgment changes from compliant to non-compliant and more than half of the remaining values are compliant; evaluated on the PROTECT dataset.
- Nature of the paper: this is an alignment/steering methods paper and does not involve attackers or a threat model; the evaluation targets are three 7B-class instruction models on workplace compliance scenarios.
What related research exists?
The paper is related to the organizational values dataset PROTECT and to two lines of research: activation steering and multi-value steering.
Organizational values and PROTECT
- Schwartz (2012) and Rokeach (1973) universal human value taxonomies—the paper considers them broad and not specific to organizations.
- PROTECT (Mittal et al., 2025)—defines 21 organizational values (six subgroups), generates 15,000 training and 3,200 test scenarios based on BeaverTails (Ji et al., 2023), each scenario annotated with relevant values and paired with compliant and non-compliant responses; this paper builds and evaluates directly on it.
- The prompting approach of Palla et al. (2025) and the fine-tuning approaches of Zhu et al. (2024) and Wang et al. (2025)—the paper states that prompts cannot guarantee compliance, and this paper studies whether not fine-tuning can more reliably follow the values in prompts.
Activation steering
- Subramani et al. (2022), Turner et al. (2023), Zou et al. (2023)—pioneering work on adding fixed vectors to hidden states, editing activations, and representation engineering.
- Inference-Time Intervention of Li et al. (2023), the refusal direction of Arditi et al. (2024), CAA of Rimsky et al. (2024), Persona Vectors of Chen et al. (2025)—various contrastive steering vector constructions; this paper's mean-difference construction is based on CAA, and the Persyn baseline is inspired by Persona Vectors.
- Tan et al. (2024)—the paper cites its conclusion that steering effects vary greatly with input and can be broken by small prompt changes.
Multi-value steering
- van der Weij et al. (2024)—compares single-layer vector merging with simultaneous multi-layer injection on Llama 2-7B-Chat and finds the latter more promising.
- Training-free combination methods: Dynamic Activation Composition (Scalena et al., 2024), conceptors (Postmus and Abreu, 2024), CONFST (Song et al., 2025), Stolfo et al. (2025), Ghasemi et al. (2026), Han et al. (2026).
- Training-based methods: MAT-Steer (Nguyen et al., 2025), MSRS (Jiang et al., 2025), K-Steering (Oozeer et al., 2025). The paper notes that these methods mainly change how vectors are combined and where they are applied, whereas this paper studies the effect of how response pairs are constructed on multi-value directions.
Baselines and benchmark: the compared methods are Values-prompt (VP), SFT (LoRA), All-values (a multi-value rewrite of CAA, with lenient/strict extraction prompts), and Persyn (synthetic single-value contrast); the benchmark is PROTECT.
Positioning: the authors state that this paper does not change how vectors are computed or applied, only how the contrastive sample pairs are constructed (per-value isolation), and diagnoses why direct activation steering fails in multi-value settings.
How does the paper address this problem?
VIAS constructs steering directions from per-value isolated contrastive response pairs, then achieves multi-value steering through weighted merging and single-layer injection.
Overall approach: keep the computation and application of steering vectors unchanged, and only change the construction of contrastive sample pairs—change only one value at a time, yielding per-value directions with smaller overlap, namely VIAS (Value-Isolating Activation Steering).
Background: Steering vectors and overlap measurement
- Activation steering adds a fixed vector to the residual stream at each decoding step in a selected layer ℓ: hℓ ← hℓ + α vℓ, where α controls the strength, with no weight updates.
- Single-value directions are constructed by contrast: di = E[ai+] − E[ai−], i.e., the difference in mean activations over response tokens between compliant and non-compliant responses (the basis of CAA).
- Direction overlap is measured by cosine similarity; a value close to 1 indicates nearly the same direction, in which case reweighting cannot produce a new steering direction.
Contrastive data construction (three kinds)
- All-values: In the same scenario, the system prompt requires complying with all annotated values to generate a compliant response, and requires ignoring all annotated values to generate a violating response; both lenient and strict extraction prompts are tested.
- Persyn: Inspired by Persona Vectors, Qwen2.5-32B is used to synthesize 50 workplace scenarios for each value (1,050 in total), then same-scenario compliant/violating contrasts are made; only the lenient prompt is used.
- VIAS: For training scenarios annotated with K≥2 values, one prompt lists all K values, and the other omits only the target value V while keeping the other instructions unchanged; a sample pair is retained only when the judge determines that the former response complies with V and the latter does not comply with V, and both responses have a compliance rate of no less than 50% for the remaining non-target values.
- About 2,965 candidate pairs per model; after filtering, retained: Qwen 384 pairs, Phi 753 pairs, Mistral 803 pairs (covering 21 values).
Direction merging and inference
- Raw: Equal-weight average of the activation differences of all retained pairs, yielding one global vector.
- Weighted: Process from the largest to the smallest number of retained pairs, use Gram–Schmidt to remove components overlapping with already-processed vectors, then merge with weights by SNR and proportional to remaining length; the cosines in Table 3 are measured before orthogonalization.
- Targeted: Use only the directions of the values annotated in the current scenario for weighted merging, rather than the global vector.
- At inference, inject step by step at a single layer, with the system prompt being a neutral prompt or a values prompt (VP); the VIAS layers are Qwen L23, Mistral L24, Phi L16, and the coefficients are swept per model within the range that maintains coherence (e.g., Qwen raw α∈{2,…,32}).
Evaluation method
- The main judge is Qwen2.5-32B-Instruct, which judges each annotated value as complies / violates / unclear, with only complies counted as success; additionally, Mistral-Small-24B-Instruct is used to re-judge 12 original runs as a sensitivity check (agreement rate 87.6%, κ=0.544).
- The main metric is strict sample compliance rate (all annotated values in the scenario comply), plus micro, macro, hard-subset recovery, and a 0–100 coherence score.
- Two human annotators annotated 248 (scenario, value) pairs; the main judge's agreement with each annotator (κ=0.40, 0.43) is no lower than the agreement between the two annotators (κ=0.25).
What experiments did the paper conduct?
On PROTECT, VIAS+VP exceeds VP alone on all three models, but the authors report that the improvement in two of these cases did not reach statistical significance.
Experimental setup
- Models tested: Qwen2.5-7B-Instruct, Mistral-7B-Instruct-v0.3, Phi-3.5-mini-instruct (3.8–7.6B parameters).
- Data: The PROTECT training set uses 3,000 scenarios (seed 0), and the test set is a fixed 800-scenario subset (seed 1); SFT uses 200 development scenarios to select the checkpoint.
- Baselines: no-steering baseline, Values-prompt (VP), SFT (LoRA, rank 16), All-values (lenient/strict), Persyn.
- Metrics: strict sample compliance rate (proportion of scenarios where all annotated values comply), micro, macro, hard-subset recovery, coherence (0–100).
- Judges: main judge Qwen2.5-32B-Instruct; second judge Mistral-Small-24B-Instruct re-judges 12 runs; statistical test is 10,000 paired bootstraps (seed 42).
- Human verification: two annotators annotated 248 (scenario, value) pairs from 60 responses.
Main results
According to Table 1 (strict sample compliance rate %, test set of 800 scenarios):
Swipe horizontally to read the table
Method Qwen2.5-7B Mistral-7B Phi-3.5-mini Baseline 60.8 63.9 61.6 VP 67.4 72.1 60.5 SFT (LoRA) 63.8 62.0 63.5 All-values (lenient) 60.4 65.8 61.6 Persyn 59.6 67.5 60.8 VIAS 62.4 66.1 66.2 VIAS + VP 69.6 75.2 72.6 VIAS, weighted + VP 69.1 75.5 69.2 - The authors state that VIAS+VP is higher than VP alone on all three models; however, paired bootstrap shows that the improvement over VP for Qwen (p=.108) and Mistral (p=.054) does not reach 5% significance (Table 7).
- Without VP, the best method differs by model: SFT for Qwen, Persyn for Mistral, and VIAS for Phi; the improvement of SFT over the base model under the same setting is supported by nominal intervals only on Phi (Appendix B).
- VP alone is actually lower than baseline on Phi (60.5% vs 61.6%).
Direction overlap diagnostics
- What was measured: pairwise cosines among 21 per-value directions (before Gram–Schmidt), with All-values using the strict prompt.
- Results: The mean cosine of All-values directions is 0.938 (Qwen), 0.911 (Mistral), 0.940 (Phi); VIAS reduces this to mean absolute cosine 0.093, 0.099, 0.453, and the effective rank rises from about 1.1 to 16.53, 16.06, 3.57 (Table 3). The authors state that VIAS reduces but does not eliminate overlap, and there is still notable overlap on Phi.
- Authors' interpretation: The overlap stems from sample-pair construction—different values reuse the same batch of "all-comply vs all-violate" responses, capturing a shared compliance signal; this does not mean the values themselves are synonymous.
Target-value specificity and recovery
- Specificity test: Using 16 Persyn scenarios per value and a neutral prompt, the ratio of the change in target-value compliance to the mean absolute change in the remaining values is computed: Qwen −0.53, Mistral −0.14, Phi 0.45 (α = 16, 12, 24 respectively). All three ratios are below 1, and Qwen and Mistral are negative; the authors state that smaller vector overlap alone does not prove that each value can be controlled independently.
- Recovery rate: Figure 3b shows that VIAS has higher hard-subset recovery than All-values on Mistral and Phi; on Qwen, All-values without prompting and the VIAS variants recover 20.9–23.7% of baseline failure pairs; the steering methods retain 95–98% of baseline compliant pairs. SFT recovers 36.3% (Qwen), 23.3% (Mistral), 31.4% (Phi), but relative to its separately evaluated base model.
Other ablations and analyses
- Targeted variant: weighted targeted All-values is lower than baseline on all three models; targeted weighted VIAS is lower than raw VIAS (Table 1).
- Data efficiency: Under the VP condition, raw VIAS using only 25% of sample pairs is slightly higher than VP alone on Qwen and Mistral; adding more sample pairs does not consistently improve (Figure 5, coefficients differ from Table 1).
- Layer and strength selection: The All-values configuration selected on the development set is lower than the original configuration on all three models (Table 9); the authors note that the two have different search spaces and this is not an equal-budget ablation.
- Reverse steering: Only Mistral at −16 shows micro compliance dropping from 0.87 to 0.63 and violation rate rising from 0.01 to 0.19; Qwen and Phi are essentially unchanged (Figure 8, 400 scenarios).
- Judge sensitivity: Under the second judge, the baseline strict compliance rate drops to 44.4–46.6%, but the signs and nominal significance determinations of the nine comparisons are unchanged (Tables 6, 7); individual configurations not included in the main table change significance after switching judges (Appendix C).
What are some points that can be further explored?
The authors list limitations such as improvements varying by model, data dependence, and reviewer bias; the experiments cover only three small models and one taxonomy.
Limitations noted by the authors and future directions
- The improvement over prompting varies by model: on Qwen and Mistral, the improvement of raw VIAS+VP does not reach the 5% significance threshold, and Phi's larger improvement cannot be explained solely by its regression under prompting (Section 8).
- Persyn and VIAS differ in the number of retained pairs, layers, and tuning; comparable development searches, paired uncertainty, and matched data controls are needed to isolate the effect of "omitting a single value" (Section 8).
- The Persyn correlation check covers only 20 scenarios and cannot prove that the synthetic scenarios isolate the target value (Section 8).
- VIAS relies on scenarios containing at least two values and having judge-clean sample pairs; coverage of rare values is sparse, and per-value coverage is uneven (Section 8).
- Steering is single-layer and constrained by a coherence threshold; the paper reports what can be achieved while maintaining fluency, not the strongest push; SFT uses only a single training seed and reuses development and test data used in prior experiments (Section 8).
- SFT with values prompts was not evaluated; the second judge and human verification did not cover the new SFT outputs; the study includes only three 3.8–7B models and one taxonomy, and collinearity in other models or layers may differ; scoring is done by LLM judges throughout, and cross-judging cannot eliminate the main judge's selection bias (Section 8).
Scope of experiments
- The models tested are Qwen2.5-7B-Instruct, Mistral-7B-Instruct-v0.3, and Phi-3.5-mini-instruct, 3 in total (Section 5).
- The evaluation benchmark is only PROTECT: 3,000 training scenarios and a fixed 800 test scenarios, with scenarios in English and a general workplace background (Appendix B).
- The compared methods are VP, SFT (LoRA), All-values (lenient/strict), Persyn, and raw/weighted/targeted variants (Table 1).
- The judge is Qwen2.5-32B-Instruct, with Mistral-Small-24B-Instruct additionally re-judging 12 runs; human verification consists of 2 annotators and 248 (scenario, value) pairs (Section 5, Appendix C).
- The paper does not report variance across multiple training or run seeds; bootstrap intervals measure only scenario-sampling uncertainty (Appendix B).
Summarize the main content of the paper
VIAS reduces steering direction overlap through per-value isolated contrastive construction, and combined with prompts achieves the highest compliance rates reported in the paper across three models.
A methods paper on multi-value activation steering, studying whether adding vectors only at inference time without changing weights can help LLM agents better comply with multiple organizational values simultaneously.
- Problem: on PROTECT (21 organizational values, each scenario annotated with a relevant subset), steering directions for different values obtained by the conventional "all-compliant vs. all-violating" contrastive construction are nearly collinear (average cosine 0.91–0.94, Table 3), capturing a generic compliance signal and limiting multi-value control.
- Method: VIAS generates responses for the same scenario using two prompts, "list all K values" and "omit only the target value," and keeps a sample pair only when the target value's judgment flips and more than half of the remaining values are compliant (384–803 pairs retained per model); it then constructs directions by mean difference and merges them with Gram–Schmidt weighting, injecting layer by layer.
- Results: the average absolute cosine of VIAS directions drops to 0.093 (Qwen), 0.099 (Mistral), and 0.453 (Phi); combined with value prompts (VP), the strict sample compliance rates are 69.6% for Qwen2.5-7B, 75.2% for Mistral-7B, and 72.6% for Phi-3.5-mini, all higher than VP alone (67.4%, 72.1%, 60.5%) (Table 1).
- Limitations: the improvements over VP for Qwen (p=.108) and Mistral (p=.054) did not reach 5% significance; the target-value specificity ratios are all below 1, and the authors state that smaller direction overlap does not by itself equal independent control of each value; without VP, VIAS is the best method only on Phi.
- Authors' conclusion: changing how contrastive sample pairs are constructed (rather than how they are weighted or combined) makes directions markedly less similar; VIAS alone is below prompts on Qwen and Mistral and above prompts on Phi, and combined with prompts achieves the highest compliance rates observed in the paper on all three models; the authors also emphasize that the best configuration still has non-compliant values in about a quarter of scenarios and cannot replace human review and governance.