Do Citations Matter? Source Quality, Citation Support, and Physician-Rated Accuracy of Google AI Overviews' Answers to Medical Information QuestionsDoes the Citation Matter? Quality, Grounding, and Physician-Rubric Accuracy of Google's AI Overviews for Medical Information
The authors audited Google AI Overviews on 3,611 HealthBench health questions, stating that its source quality, statement attribution and accuracy against physician standards all fall short of traditional search.
- Google AI Overviews has become the first result in search, shifting the work of filtering sources from users to Gemini; errors in health information carry health risks, and it is unclear whether AIO inherits traditional search's health source quality standards.
- The authors submitted 3,611 HealthBench health questions verbatim to Google, compared source overlap between each AIO and the conventional top 5 results, automatically assessed source quality using JAMA and HONcode criteria, used the HallOumi classifier to test whether statements were supported by cited pages, and scored AIOs with GPT-4.1 against physician-written scoring criteria.
- 96.4% of questions returned an AIO; only 44.4% of conventional top 5 results were cited by AIO; AIO sources were lower than conventional results on four of six quality indicators; after correction, an estimated 56.7% of scorable statements were supported by sources; AIO received 38.2% of available points, and 22.2% contained content physicians judged harmful.
- The authors note that measurement relied on automated coding, HallOumi and GPT-4.1, and should be treated as relative comparisons rather than absolute quality; HealthBench questions are longer than typical queries and the criteria were designed for longer answers; some pages could not be captured; data were collected over 3 days and AIO keeps changing.
- Evaluated models
- Google's AI Overviews (Gemini)
- Benchmarks
- HealthBench
- Metrics
- JAMA criteriaHONcodestatement support raterubric score (% of available points)Cohen's dzSpearman's ρ
The researchers evaluated Google AI Overviews with 3611 benchmark health questions and found that its cited sources differ markedly from traditional search, with lower citation support and physician-rated accuracy. AI Overviews appeared for 96.4% of questions, but only 44.4% of the top five traditional search results were cited by the corresponding overview, and it cited commercial health sites such as WebMD and Healthline more and academic and government sources such as Cleveland Clinic and NHS less, with cited pages scoring lower than traditional results on four of six credibility criteria. After correcting for classifier error, an estimated 56.7% of cited statements were supported by the cited page, and another 20.8% of statements were factual assertions without citations. Under physician-written scoring criteria, AI Overviews received 38.2% of the available score, including 54.2% for accuracy and 21.6% for completeness; in the subset where the scoring criteria expected specific errors or potentially harmful claims, 22.2% of overviews contained harmful content, and overview accuracy was unrelated to citation support.
Paper analysis
What problem does this paper attempt to solve?
Auditing Google AI Overviews' source quality, statement attribution, and accuracy against physician standards in the health domain.
Core question: In the high-stakes domain of health, whether Google's AI Overviews (AIOs) cite trustworthy sources, whether statements are supported by sources, and whether answers meet physician standards had not previously been systematically characterized.
- Setting and importance: AIO uses Gemini plus retrieval-augmented generation (RAG) to give cited answers and is the first result 2.5 billion monthly active users see when searching; after receiving an AIO, users click conventional search results less often and rarely check sources (Introduction). The authors consider health queries high-risk, where inaccurate information may lead to worse health outcomes.
- Gap in existing knowledge: Conventional search algorithms have been optimized for years to prioritize academic and government sources in health; but the authors state that when AIO was deployed, little was known about how it affects the information ecosystem, prior studies were mostly in non-health domains, and they found AIO cited user-generated content more than conventional search.
- Core observation: The authors state that AIO's accuracy and fidelity to citations are increasingly the main safeguard for users obtaining online information, so direct auditing is needed.
- What the paper did: Four complementary analyses on 3,611 HealthBench health questions—overlap between AIO sources and conventional top 5 results, source quality (JAMA and HONcode criteria), statement attribution (HallOumi classifier), and scoring with GPT-4.1 against physician-written criteria—and tested whether source quality and attribution predict accuracy.
What related research exists?
Related work falls into four groups: AIO and generative search audits, health information quality, LLM health answers and citations, and the HealthBench benchmark.
Empirical Audits of AIO and Generative Search
- Grossman et al. (2026)—found long queries trigger AIO more often than short queries; Kirsten et al. (2025)—characterized web search in the generative AI era.
- Hagar and Diakopoulos (2026)—found that in non-health domains AIO cited user-generated content more than conventional search; Xu et al. (2026)—measured AIO trigger rate, source quality, and claim fidelity; the paper notes their finding that in non-medical queries AIO cited more trustworthy domains than conventional top results and had an 11% unsupported rate, which differs from this study's conclusions; the authors suggest this may be because their queries were simpler and they used Grok 4.1 Fast Reasoning rather than a classifier.
- Hu et al. (2026)—audited AIO for infant care and pregnancy questions and found basic medical safety notices were omitted in the vast majority of AIOs.
Health Information and Search Quality
- Google's search quality evaluator guidelines and anti-misinformation documentation (Google, 2019)—conventional algorithms prioritize trustworthy sources in health; Strzelecki (2020)—discussed how Google's medical update reduced the visibility of health websites.
- JAMA criteria (Silberg et al., 1997) and HONcode (Bayani et al., 2023)—the source quality assessment tools used in this paper.
LLM Health Answers, Citations, and Trust
- Tiller et al. (2026)—found nearly half of common health answers from advanced LLMs were misleading or incomplete; Shekar et al. (2025)—found people trust LLM medical advice as much as physicians.
- Ding et al. (2025)—found citations in LLM answers increase trust; Oumi's HallOumi evaluation (New York Times report, 2026)—the same classifier found 67% of statements supported in a non-academic evaluation, used here as a comparison.
Benchmark and baseline: Data come from OpenAI's HealthBench (Arora et al., 2025), containing 5,000 real health questions with physician-written scoring criteria; the control group is the top 5 non-video results of Google conventional search for the same query.
The authors position this paper as a complementary audit of AIO's citation quality, attribution, and accuracy in the high-stakes health domain, distinct from prior research focused mainly on non-health queries.
How does the paper address this problem?
Crawled AIO and conventional top 5 results for 3,611 HealthBench questions, evaluating along four lines: source overlap, quality, attribution, and physician criteria.
Overall approach: HealthBench health questions were submitted verbatim to Google, while the full AIO text and citations and the traditional top 5 results were captured, and automated tools were used to evaluate AIO along four complementary dimensions.
Question selection and classification
- Data source: OpenAI's HealthBench contains 5,000 real health questions, each with physician-written scoring criteria; after filtering to English, health-focused questions answerable by medical professionals, 3,611 questions remained (Section 2.2).
- Complexity and risk grading: by number of criteria, low (2–3), medium (4–7), high (8+) complexity; by HealthBench's seven topics, low, medium, high risk, with high risk including emergency referrals and response depth (Section 2.1, Table 1).
Data capture
- Query method: submitted via SerpAPI on September 16–18, 2026, with region fixed to U.S. English; 1 question failed on two attempts, and 3,610 questions had results (Section 2.3).
- Captured content: for each question, the full AIO text and all citations, plus the top 5 traditional non-video results; pages were captured using a tiered method of direct HTTP, trafilatura, headless Chromium, AMP, Jina Reader, and the Wayback Machine, with Reddit and Quora posts excluded (Appendix A.1, A.2).
Source quality (JAMA and HONcode)
- Automated scoring: a rule-based Python scorer coded 0/1 on JAMA's four dimensions (authorship, attribution, currency, disclosure) and HONcode's two dimensions (Authority, Complementarity); the other two HONcode criteria were dropped for duplicating JAMA or being unreliably codable (Section 2.4).
- Human agreement: agreement with human coding of 3 pilot questions (174 judgments) was 84%, Cohen's κ = .68 (Table A3).
Statement attribution (HallOumi)
- Classifier: the public classifier HallOumi (oumi-ai/HallOumi-8B-classifier) was used to give each statement a supported/unsupported judgment and confidence; the four judgments were supported, unsupported, indeterminate (reported as skipped), and uncited (Section 2.5).
- Decision thresholds: at sentence level, an entailment probability of 0.50 for any cited page window counted as support; at statement level, at least 50% of factual sentences passing counted as support; only the citations attached to that statement were checked (Appendix A.5).
- Error correction: agreement in 100 human verifications was 81% (κ = .61); of 19 disagreements, 16 were cases where humans judged support and HallOumi did not, so the authors treat the support rate as a lower bound and give a corrected value using the Rogan–Gladen estimator (Section 2.5, Appendix A.5).
Physician criteria scoring
- Scorer: following the HealthBench protocol, GPT-4.1 scored each criterion separately, with criterion values from −10 to 10; 3,474 AIOs had 41,180 criteria in total (median 12 per question), of which 12,218 (about 30%) were content to be avoided (Section 2.6, Appendix A.6).
- Validity: on a 3,000-item physician-scored subsample, GPT-4.1's macro-F1 with physicians was .707, higher than the .681 agreement among physicians (Section 2.6).
- Metrics: score = sum of points for satisfied criteria ÷ total available points; the paper highlights accuracy and completeness (together called clinical score), and also reports context awareness, communication quality, consensus criteria, instruction following, harmful content rate, and appropriate referral rate (Section 2.6).
Statistical analysis
- The unit of analysis was the question; per-question means of AIO-cited pages and traditional top 5 were compared with paired t-tests, effect size Cohen's dz, with Benjamini–Hochberg FDR correction across the six quality metrics; citation occurrence and support rates used Cochran–Armitage and chi-square tests; correlations of criterion scores with quality and attribution used Spearman's ρ; robustness checks repeated on single-turn questions of ≤44 words (n = 1,714) (Section 2.7).
What experiments did the paper conduct?
Four analyses of 3,481 AIOs: 44.4% source overlap, lower on four of six quality indicators, 56.7% of statements supported after correction, guideline score 38.2%.
Experimental Setup
- System under test: Google AI Overviews (Gemini + RAG), compared against the top 5 non-video results of conventional search for the same query.
- Data: 3,611 HealthBench questions; 3,481 returned an AIO (96.4%), 3,474 had usable AIO text (≥200 characters), and 3,103 had readable pages on both sides and entered the paired comparison (Table A1).
- Evaluation methods: Source quality used a rule-based automated scorer (84% agreement with humans, κ = .68); statement attribution used the HallOumi-8B classifier (81% agreement with humans, κ = .61); guideline scoring used GPT-4.1 (macro-F1 = .707 with physicians).
- Metrics: Source overlap proportion, paired dz on the six JAMA/HONcode 0/1 indicators, statement support rate (proportion supported among scorable statements), guideline score (percentage of available points).
- Sample sizes: 12,175 of 24,060 statements were scorable; 41,180 criteria; robustness check n = 1,714.
Main Results
Metric Value Source Proportion of questions returning an AIO 96.4% (3,481/3,611) Abstract, Section 3 Proportion of conventional top-5 results cited by AIO 44.4% (n = 6,412) Section 3.1 Scorable statements supported by cited pages (observed) 47.1% (n = 5,735/12,175) Section 3.3 Support rate estimate after correcting HallOumi error 56.7% (95% CI [45.3, 68.6]) Section 3.3 Uncited factual statements as share of all statements 20.8% (n = 4,996/24,060) Section 3.3 Overall guideline score (percentage of available points) 38.2% (n = 3,474) Table 3 Accuracy / Completeness 54.2% / 21.6% Table 3 Proportion of AIOs containing content physicians judged harmful 22.2% (n = 2,065) Table 3 - The authors state that AIO and conventional search diverge in source selection: AIO cited an average of 8.50 sources (n = 3,154), but 55.6% of the conventional top 5 were not cited by AIO; AIO cited more commercial health publishers (webmd.com, healthline.com), while conventional results cited more academic and government domains (Table A5).
- The authors state that AIO lost points mainly through omissions rather than incorrect statements (89% of lost points from omitted content, 11% from incorrect statements); 93.4% of AIOs passed the generic "no factual errors" criterion, but 28% of those that passed still contained harmful content.
- The authors state that AIO accuracy was unrelated to its statement attribution (ρ = .01, p = .467), and uncited AIOs scored similarly to cited AIOs (40.4% vs. 39.2%).
Source Quality Comparison
- What was measured: The six JAMA/HONcode indicators for AIO-cited pages versus conventional top 5 on 3,103 paired questions (Table A6, Figure 2).
- Results: After FDR correction, conventional sources scored higher on four indicators—HON Authority (dz = −0.19), JAMA Disclosure (dz = −0.12), JAMA Currency (dz = −0.09), JAMA Attribution (dz = −0.06, p = .002); JAMA Authorship (dz = 0.00) and HON Complementarity (dz = −0.02) showed no difference.
- Authors' interpretation: The authors state the differences were small (|dz| ≤ 0.19) and that AIO relied on domains with lower transparency; when comparisons were repeated within each risk and complexity level, conventional results were preferred in all cases (Appendix B.2).
Stratified Analysis of Uncited AIOs and Statement Attribution
- Uncited AIOs: 327 AIOs had no citations at all; the uncited proportion rose with complexity (low 4.2%, medium 6.0%, high 10.6%) and with risk (low 6.4%, medium 8.1%, high 17.6%), trend test p < .001 (Figure 1).
- Attribution strata: Support rate fell with complexity (low 52.2%, medium 47.4%, high 46.3%, p < .001); by risk it was non-linear (low 45.0%, medium 48.9%, high 46.4%) (Figure 4).
- Authors' interpretation: The authors state that the longer, more complex, and higher-risk the question, the more likely AIO was to generate an answer without citations; about half of cited statements were not adequately attributed.
Stratified and Correlation Analyses of Guideline Scores
- By complexity and risk: Clinical score was 76.7% for low complexity, 28.8% for medium, and 35.7% for high; by risk it was 26.7% for low, 43.4% for medium, and 52.4% for high; the authors state the high score at high risk stems from the emergency referrals topic, and after removing referral criteria the high-risk score was 35.9% (Table A7).
- Correlation with source quality: Weak negative correlation with total JAMA score (ρ = −.05, p = .003), weak positive correlation with HONcode (ρ = .10, p < .001).
- Referral performance: Among 413 emergency-referral questions, 94.9% of AIOs referred with appropriate urgency (Table 3).
Other Ablations and Analyses
- Robustness check on short single-turn questions (n = 1,714): main conclusions unchanged; uncited AIOs fell from 9.4% to 5.8%, JAMA Attribution no longer differed, and attribution showed a weak correlation with accuracy (ρ = .06, p = .013) (Table A4).
- Question length: questions with uncited AIOs were longer (M = 73.5 words vs. 40.5 words, d = 0.75) (Section 3).
- Satisfaction rate for generic consensus criteria was 84.2%, far above the 43% for question-specific criteria (Section 3.4).
What are some points that can be further explored?
The authors list limitations including automated measurement, question representativeness, crawl failures, and the 3-day sampling window, and recommend auditing other high-risk topics.
Limitations and future directions noted by the authors
- Automated measurement: the authors note that given the data scale, measurement relied on automated coding, HallOumi and GPT-4.1; although these have reasonable agreement with humans or physicians, they should not be treated as an absolute reflection of AIO quality, attribution and accuracy, but as relative comparisons (Discussion).
- Question representativeness: HealthBench questions were designed for an LLM dialogue benchmark and are longer than typical Google queries, raising the proportion of uncited AIOs; the authors also note this may represent the longer questions users ask in the AIO era (Discussion).
- Criteria fit: HealthBench criteria were designed for longer answers than AIO, and scores correlate with length (ρ = .14), which may disadvantage shorter AIOs (Discussion).
- Missing pages: some pages (blocking automated access, social media posts) could not be captured and were not included in the analysis (Discussion).
- Timeliness: capture was conducted over only 3 days, and AIO keeps changing with model updates (Discussion).
- Future directions: the authors suggest future work could continue auditing other high-impact, contested topics (such as science, politics, conspiracy theories) (Discussion); the authors describe this study as an exploratory first study of an emerging issue (Discussion).
Scope of the experiment
- The system under test was one, Google AIO, with the traditional top 5 results as comparison; the data were 3,611 English HealthBench health questions, of which 3,481 returned an AIO and 3,103 entered the paired analysis (Table A1).
- Queries were submitted via SerpAPI with U.S. English region on September 16–18, 2026 (Section 2.3).
- Evaluation tools: source quality by a rule-based automated scorer, attribution by HallOumi-8B, criteria scoring by GPT-4.1; human verification subsamples were 174 judgments, 100 statements, and 3,000 physician scores respectively (Sections 2.4–2.6).
- The authors state they cannot distinguish explanations such as "AIO is mainly generated from model weights" and "citations do not represent the content the model relied on," because this would require an explicit comparison of Gemini without RAG and AIO with RAG, which this study did not do (Discussion).
- The paper does not report settings details for GPT-4.1 scoring beyond sampling parameters, nor the number of repeated queries per question (each question was submitted once, and 1 question was retried once and still failed) (Section 2.3).
Summarize the main content of the paper
Auditing Google AIO on 3,611 health questions: sources, attribution and accuracy all fall short of physician and traditional search standards.
This is an audit study of Google AI Overviews in the health domain, answering "whether AIO's citations are trustworthy, whether statements are supported by sources, and whether answers meet physician standards."
- Question: AIO is the first result users see in search, shifting source filtering from users to Gemini; errors in health information carry real risks, and whether AIO inherits traditional search's health quality standards was previously unknown.
- Method: 3,611 HealthBench health questions were submitted verbatim to Google, comparing source overlap between AIO and the traditional top 5 results; source quality was automatically assessed using JAMA/HONcode criteria; statement attribution was tested with the HallOumi classifier; and GPT-4.1 scored answers against physician-written criteria.
- Sources: 96.4% of questions returned an AIO, but only 44.4% of traditional top 5 results were cited by AIO; AIO cited commercial health publishers more, and was lower than traditional results on four of six quality metrics (largest dz = −0.19, HON Authority).
- Attribution: only 50.6% of statements could be scored against citations, of which 47.1% were supported, estimated at 56.7% after correcting for classifier error; another 20.8% of statements were uncited factual claims.
- Accuracy: AIO received 38.2% of available points (accuracy 54.2%, completeness 21.6%); among the 2,065 questions where physicians anticipated a specific harmful claim, 22.2% of AIOs contained that content; accuracy was uncorrelated with statement attribution (ρ = .01).
- Authors' conclusions: the authors recommend AIO literacy interventions for users and teaching users to check sources, and recommend that Google make AIO at least meet its traditional health ranking standards, and disable AIO or redirect to advice to see a doctor when questions are too complex or high-risk; the authors state that even the upper confidence interval bound did not reach the standard acceptable for health information.