Skip to content

MedCUA-Bench: a screenshot-only benchmark for clinical computer-use agentsMedCUA-Bench: A Screenshot-Only Benchmark for Clinical Computer-Use Agents

arXiv· arXiv:2606.03203· Jia Yu, Zilong Wang, Xinyang Jiang, Dongsheng Li, Shuo WangDigital Medical Research Center, School of Basic Medical Sciences, Fudan University; Shanghai Key Laboratory of MICCAI; Microsoft Research AsiaIndexed by this site · 23 days ago· Originally publishedEvaluation

Quick read

Evaluation and benchmarks

Based on the paper PDF (AI-generated); refer to the original

The authors propose the clinical GUI agent benchmark MedCUA-Bench; among 23 agents, GPT-5.4 has a strict success rate of 54.2%, and on real OpenEMR all are below 9%.

Questions
Existing GUI agent benchmarks concentrate on general web pages and desktop software, lacking coverage of clinical software; clinical interfaces require domain knowledge, have distinctive designs, lack public test environments, and binary completion rates cannot capture "completed but unsafe" failures.
Methods
The authors build MedCUA-Bench: 18 clinical scenarios, with 216 base tasks registered as 432 instances at dual intent/step granularity; agents operate only from screenshots, and a deterministic checker scores five safety dimensions and gives rewards with severity penalties.
Experiments and results
Among 23 agents, GPT-5.4 ranks first with a strict success rate of 54.2%, and the open-source average is 2.5%; on real OpenEMR all models are below 9%, and on the OHIF imaging layer several open-source models exceed 30%; across 9,936 episodes, 0 critical violations were recorded, and failures are mainly step-budget exhaustion.
Limitations and future work
The authors note: success rates on synthetic scenarios should be regarded as an upper bound; the human baseline is only a single-person pilot of 24 runs; each task is run only once; the checker is currently rarely triggered, and zero critical violations cannot be taken as a safety conclusion.
Experimental setupGPT-5.4、Claude-Opus-4.7 et al. · MedCUA-Bench · strict success rate、safety-aware episode reward et al.
Evaluated models
GPT-5.4Claude-Opus-4.7Claude-Sonnet-4.6Kimi-K2.6GPT-5-MiniGemini-3.1-ProQwen2.5-VL-32BQwen2.5-VL-72B-AWQInternVL3.5-14BGemma-3-27BInternVL3.5-8BQwen3.5-27BKimi-VL-A3BPhi-4-MultimodalGemma-4-E4BA3-Qwen3.5-9BQwen3.5-9BOpenCUA-7BOpenCUA-32BFara-7BUI-TARS-7B-DPOGLM-4.1V-9BIdefics3-8B
Benchmarks
MedCUA-Bench
Metrics
strict success ratesafety-aware episode rewardtimeout rateaverage steps
AI summaryResearchers propose MedCUA-Bench, a benchmark that evaluates clinical computer-use agents solely through screenshot interaction, covering 18 clinical scenarios across 10 medical domains, with scenarios reconstructed from real product manuals and open-source medical systems to avoid licensing and privacy constraints. Each task has intent-level and step-level goals, separating clinical reasoning from interface execution, and a deterministic checker evaluates both task completion and five clinical safety dimensions. In evaluations of 23 agents, the best closed-source model achieved a strict success rate of 54.2%, all models scored below 9% on the real OpenEMR, and open-source agents averaged only 2.5%, with the best at 16.2%. The benchmark reveals the gap between current agents and reliable clinical software use, providing a reproducible test environment for future research.

Researchers propose MedCUA-Bench, a benchmark that evaluates clinical computer-use agents solely through screenshot interaction, covering 18 clinical scenarios across 10 medical domains, with scenarios reconstructed from real product manuals and open-source medical systems to avoid licensing and privacy constraints. Each task has intent-level and step-level goals, separating clinical reasoning from interface execution, and a deterministic checker evaluates both task completion and five clinical safety dimensions. In evaluations of 23 agents, the best closed-source model achieved a strict success rate of 54.2%, all models scored below 9% on the real OpenEMR, and open-source agents averaged only 2.5%, with the best at 16.2%. The benchmark reveals the gap between current agents and reliable clinical software use, providing a reproducible test environment for future research.

Paper analysis

6 questions; open one to read the full answer

  1. What problem does this paper attempt to solve?

    Existing GUI benchmarks do not cover clinical software; the authors propose the clinical computer-operation agent benchmark MedCUA-Bench.

    Core problem: the reliability of computer-use agents (CUAs) on medical GUIs lacks verification and cannot be measured by existing benchmarks.

    • Scenario and motivation: The authors state that clinicians spend substantial time on documentation systems such as EHRs, and that if CUAs could automate repetitive screen operations such as triage notes and order entry, they could reduce physicians' burden.
    • Shortcomings of existing benchmarks: The authors point out that existing benchmarks focus on general web or desktop tasks, whereas medical software differs in four respects: it requires domain knowledge, its UI design differs greatly from mainstream applications, it lacks public test environments (real systems are regulated, closed-source, and have no API/DOM access), and it requires safety verification beyond task completion rates.
    • Core observation: Binary task-completion metrics miss clinically meaningful failures — an agent may appear to complete a task while actually operating on the wrong patient, entering incorrect data, or violating workflow (Figure 1).
    • What the paper proposes: MedCUA-Bench, an interactive benchmark covering 18 clinical scenarios across 10 medical domains, with interfaces reconstructed from real product manuals and open-source medical systems; each task has dual-granularity intent and step goals, and a deterministic checker evaluates task completion and five clinical safety dimensions. The authors state this is the first benchmark to evaluate CUAs across complete clinical workflows in an executable GUI.
  2. What related research exists?

    Related work falls into three groups—general GUI benchmarks, professional software benchmarks, and medical agent benchmarks—and the authors state that none of them covers safety evaluation of executable clinical GUIs.

    General GUI and web agent benchmarks

    • MiniWoB++ (Liu et al., 2018), WebShop (Yao et al., 2022), Mind2Web (Deng et al., 2023) — progressing from early web form filling to simulated and real web environments.
    • WebArena, VisualWebArena (Zhou et al., 2024; Koh et al., 2024), OSWorld, Windows Agent Arena (Xie et al., 2024; Bonatti et al., 2024) — standardized evaluation on self-hosted web stacks and full operating systems.
    • BrowserGym (Drouin et al., 2024; Chezelles et al., 2025) — unifies multiple environments under the Gymnasium interface and is the construction foundation of this paper. On the model side, SeeAct, CogAgent, ScreenAgent, etc. are mentioned as precedents for pixel-level operation, but the authors note they are almost exclusively evaluated on consumer applications.

    Professional and scientific software GUIs

    • ScienceBoard (Sun et al., 2026) — evaluates agents on real scientific applications such as ChimeraX, Celestia, and GRASS GIS.
    • SpreadsheetBench (Ma et al., 2024) — office spreadsheet workflows. The authors state that these works have shown that general CUAs transfer poorly to vertical software, but they do not address clinical privacy, terminology, and safety constraints.

    Medical agent benchmarks

    • AgentClinic (Schmidgall et al., 2024) — simulates clinical dialogue and tests diagnostic reasoning; MedAgentBench (Jiang et al., 2025) — evaluates EHR tasks through structured FHIR APIs rather than graphical interfaces; MedCalc-Bench (Khandekar et al., 2024) — textual clinical calculation.
    • MedSPOT (Shakeel et al., 2026) — workflow-aware visual grounding for clinical software; the authors note it does not evaluate end-to-end execution, persistent writes, or safety penalties.
    • HealthAdminBench (Bedi et al., 2026) — CUAs on healthcare administrative workflows; the authors note that this paper targets executable clinical care GUIs with explicit safety evaluation.

    Baselines and comparison: This is a benchmark paper with no method baseline; Table 1 compares MedCUA with the above 11 benchmarks on attributes such as medical domain, real clinical software, pixel-level operation, dual-granularity goals, safety evaluation, and deterministic checker, with MedCUA being the row that satisfies all. Authors' positioning: previously no benchmark covered complete clinical workflows in an executable GUI with safety-aware evaluation.

  3. How does the paper address this problem?

    MedCUA-Bench builds its evaluation with three fidelity tiers of environments, intent/step dual-granularity targets, and a five-dimension deterministic safety checker.

    Overall approach: the benchmark MedCUA-Bench was built around three requirements—clinical coverage, dual-granularity targets that separate planning from execution, and deterministic scoring that reflects safety—with each scenario implemented as a BrowserGym environment, and two practicing physicians involved in the design process.

    Clinical Environments

    • Scale and stratification: 216 base tasks covering 18 clinical scenarios and 10 medical domains (Outpatient, Inpatient, ICU, Nursing, PACS/Pathology, Imaging, RadTherapy, ECG, Endoscopy, Ultrasound), divided into three page-fidelity tiers.
    • Synthetic layer: 15 scenarios are shadow GUIs—synthetic HTML interfaces reconstructed from product manuals and clinical workflow descriptions, preserving the layout, interaction patterns and task constraints of the real interfaces.
    • Real-system layer: 1 scenario is OpenEMR v7.0.2 in Docker, preloaded with 5 demo patients; 2 scenarios are OHIF Viewer connected to a DICOMweb endpoint, requiring browsing of real radiology and pathology images.

    Target Design and Task Generation

    • Dual-granularity targets: each base task contains a scenario seed, an expected-value dictionary, a deterministic checker and two natural-language targets. The intent target states the clinical goal in the voice of a senior physician delegating it; the step target gives a click-by-click procedure for the same goal. The environment and checker are identical; only the process detail in the prompt differs.
    • 432 instances: each base task is registered once under each of the two targets, for 432 evaluation instances in total, used to distinguish workflow-inference failures from pixel-level execution failures.
    • Scenario seeds: the seed controls patient identifiers, vital signs, queue order and distractor content (synthetic scenarios), or selects demo patients/imaging studies (OpenEMR/OHIF); the interface and checker remain unchanged.

    Agent Interface

    • Observation: at each step the agent receives the current browser screenshot, the task goal, a brief history of actions and the error message from the previous step.
    • Action space: BrowserGym pixel interface—integer-coordinate mouse clicks, pointer movement, scrolling, keyboard input and shortcuts, history and tab control, user messages, infeasibility reports; element-ID actions are disabled, one atomic action per step.
    • Hidden traces: the environment additionally records all top-level navigations and outbound HTTP requests (method, URL, payload), invisible to the agent and used only by the checker to audit what was actually written.

    Safety Evaluation and Reward

    • Safety checker: at episode end it compares the final page state, the agent's final message, the request trace, the navigation trace and the expected values, returning a strict completion flag, a subtask progress vector and a list of violations.
    • Five safety dimensions: patient identity, data accuracy, information fidelity, record integrity, workflow safety; violations are graded critical (weight 1.0, may directly harm the patient), major (0.3) and minor (0.05), and a critical violation terminates the episode immediately.
    • Reward function: r = clamp(stask − ∑v ∈ V∗ w(v), −1, +1), where s_task is the strict completion flag and V* is the deduplicated violation set; a clean completion scores +1, no progress scores 0, and a completion with violations may score lower than taking no action.
  4. What experiments did the paper conduct?

    Each of 23 agents ran 432 instances once; GPT-5.4 ranked first with a strict success rate of 54.2%, and on real OpenEMR all models were below 9%.

    Experimental Setup

    • Models tested: 23 agents with visual capabilities—6 closed-source (GPT-5.4, Claude-Opus-4.7, Claude-Sonnet-4.6, Kimi-K2.6, GPT-5-Mini, Gemini-3.1-Pro) and 17 open-source vision-language models (including Qwen2.5-VL-32B/72B-AWQ, InternVL3.5-14B/8B, Gemma-3-27B, Qwen3.5-27B/9B, Kimi-VL-A3B, Phi-4-Multimodal, Gemma-4-E4B, A3-Qwen3.5-9B, OpenCUA-7B/32B, GLM-4.1V-9B, Idefics3-8B, Fara-7B, UI-TARS-7B-DPO); open-source models were deployed with vLLM on a single A100 80GB.
    • Benchmark: MedCUA-Bench, 216 base tasks × 2 target granularities = 432 instances.
    • Protocol: all used the screenshot-only AgentLab harness, with DOM, accessibility tree and set-of-marks disabled; each model ran each of the 432 instances once, with a 30-step budget per episode; an episode terminates on task completion, a critical violation, or budget exhaustion.
    • Metrics: strict success rate (cumulative reward at termination reaches the completion threshold and there is no safety penalty), safety-aware reward (Eq. 1), environment truncation rate, average number of steps.
    • Evaluation method: deterministic checker, no LLM judge; the human baseline is a pilot with a single trained operator on 24 paired runs (Appendix P).

    Main Results

    According to Table 2 (listing only the 19 models with non-zero strict success rate; the full 23 models are in Table A.1):

    Swipe horizontally to read the table

    ModelSuccess rate (%)RewardTruncation rate (%)Average steps
    GPT-5.454.20.56343.318.5
    Claude-Opus-4.752.60.55143.318.1
    Claude-Sonnet-4.645.40.47253.019.7
    Kimi-K2.630.80.31666.222.7
    GPT-5-Mini14.60.15085.227.3
    Gemini-3.1-Pro4.60.04695.129.0
    Qwen2.5-VL-32B16.20.17382.225.0
    Qwen2.5-VL-72B-AWQ6.20.06491.928.5
    InternVL3.5-14B3.90.03995.828.7
    OpenCUA-32B0.50.00599.3NA

    (Omitted: InternVL3.5-8B 2.8%, Qwen3.5-27B 2.3%, Kimi-VL-A3B 1.9%, Phi-4-Multimodal 1.4%, Gemma-4-E4B 1.2%, A3-Qwen3.5-9B 1.2%, Qwen3.5-9B 1.2%, OpenCUA-7B 0.9%; 4 additional zero-success models are in Table A.1.)

    • Closed-source/open-source gap: the authors report an average success rate of 33.7% for closed-source and 2.5% for open-source; the strongest open-source model, Qwen2.5-VL-32B (16.2%), is below the four stronger closed-source models.
    • Scale does not narrow the gap: the authors report that Qwen2.5-VL-72B-AWQ (6.2%) is below Qwen2.5-VL-32B, and Qwen3.5-27B is only 2.3%; the authors believe MedCUA rewards the visual grounding and interface control capabilities emphasized by Qwen2.5-VL rather than generational improvements in the language backbone.
    • CUA-specific models are also near the bottom: OpenCUA-7B 0.9%, OpenCUA-32B 0.5%.

    Page Fidelity Analysis

    • What was measured: Figure 4 compares success rates across three groups: synthetic HTML, real OpenEMR, and OHIF imaging.
    • Results: on OpenEMR all models fall in the 0–8.3% range, with GPT-5.4, Claude-Opus-4.7 and Claude-Sonnet-4.6 tied at 8.3%, and Gemini-3.1-Pro and Kimi-K2.6 at 0; on the OHIF layer several open-source models approach the leading closed-source models—Qwen2.5-VL-72B-AWQ 45.8%, InternVL3.5-14B 35.4%, Qwen2.5-VL-32B 33.3%, Gemma-3-27B 31.3%.
    • Authors' interpretation: general screenshot GUI capabilities transfer poorly to deployed EHRs (nested menus, modal dialogs, dense forms); the OHIF interface is relatively sparse, so the benchmark thereby separates the two capabilities of clinical software navigation and visual measurement reporting.

    Target Granularity and Safety Profile

    • Step targets help strong models: Figure 5 shows that the four strongest closed-source models all improve under step targets—GPT-5.4 rises from 51.9% to 56.5% (+4.6 pp), Kimi-K2.6 from 28.2% to 33.3% (+5.1 pp); most open-source models instead decline, e.g. Qwen2.5-VL-32B from 18.5% to 13.9%. The authors believe weaker models are already hampered by the long-process text itself.
    • Safety violations are rare: across 9,936 episodes the checker recorded 0 critical, 53 major and 15 minor violations (Figure 7); the 6 closed-source models together had only 5, all minor. The authors explicitly state that this does not mean strong agents are clinically safe—most agents get stuck before reaching safety-critical interfaces, and the checker currently has limited discriminative power.

    Failure Modes and Other Analyses

    • Failure breakdown (Figure 6, Table J.1): among 8,877 failed episodes, closed-source failures are mainly exploration timeouts (53.5%), while open-source failures are mainly format lock-in (41.3%, never emitting a parseable action) and heavy looping (45.4%); 99.0% of successful episodes completed within 30 steps (median 7 steps).
    • Format lock-in vs. grounding limitation: the authors report that some CUA fine-tuned models revert to the private action format used in training; Gemini-3.1-Pro produces well-formed actions at every step but has a success rate of only 4.6%, and the authors believe pixel grounding rather than instruction following is its main bottleneck on clinical GUIs.
    • Other ablations and analyses: difficulty stratification (Appendix G)—GPT-5.4 88.8% on easy tasks and 26.7% on hard tasks; severity-weight sensitivity (Appendix M)—under 10 alternative weighting schemes the model ranking has Spearman ρ ≥ 0.957, and the authors call this robustness mechanical (too few violations); human pilot (Appendix P)—a single operator achieved 83.3% success over 24 runs (95% Wilson CI [64.1, 93.3]), 29.1 pp higher than GPT-5.4; shadow GUI and real-layer rankings are correlated (Appendix B, ρ = 0.720/0.710).
  5. What are some points that can be further explored?

    The authors list limitations such as synthetic fidelity, single runs, and the checker not being sufficiently triggered, and plan a complete human baseline.

    Limitations and Future Directions Noted by the Authors

    • The synthetic layer is an upper bound (Limitations): the 15 synthetic HTML scenarios reproduce the reference systems' workflows and terminology but not their full visual appearance, so success rates on the synthetic layer should be regarded as an upper bound on the same agent's performance on real vendor systems; the authors consider the OpenEMR (8.3%) and OHIF (72.9%) upper bounds to be more reliable readings.
    • The human baseline is only a pilot (Limitations, Appendix P): only a single trained operator completed 24 paired runs (83.3%, 95% Wilson CI [64.1, 93.3]); the authors leave a full multi-annotator human baseline to future work.
    • Single run (Limitations): each agent is evaluated only once per task; results are point estimates and do not capture run-to-run variance.
    • The safety checker is not sufficiently triggered (Limitations): the most common failure at present is exhausting the step budget rather than confident erroneous actions, so zero critical violations should be read as a lower-bound measurement under current capabilities and not as a positive safety conclusion.
    • Directions in the conclusion: the authors note that production-grade EHR screenshots, longer-horizon and multi-seed evaluation, and dense small-text clinical interfaces are important goals for future agent training and evaluation.

    Scope of the Experiments

    • The models tested are 23 visual agents (6 closed-source, 17 open-source); each model ran all 432 instances once, for 9,936 episodes in total (§4.1).
    • The environments cover 18 scenarios, 10 medical domains and three fidelity tiers, with the real systems being OpenEMR v7.0.2 (5 demo patients) and OHIF Viewer (§3.1).
    • The human evaluation is a pilot with 1 operator × 24 runs; the paper does not report multi-annotator agreement (Appendix P).
    • Safety evaluation relies on a deterministic checker and preset expected values, with no LLM judge; across 9,936 episodes, 68 non-critical violations were recorded in total (§4.5).
    • The paper does not report multiple repetitions per task, sampling-temperature variation or prompt-perturbation experiments; all open-source models were deployed with vLLM on a single A100 80GB and were not fine-tuned on MedCUA (Appendix N).
  6. Summarize the main content of the paper

    MedCUA-Bench evaluates 23 clinical GUI agents: the strongest closed-source model reaches 54.2%, and on real EHRs all are below 9%.

    MedCUA-Bench is an interactive benchmark for clinical computer-use agents (CUAs), addressing the problems that existing GUI benchmarks do not cover medical software and that binary completion rates miss safety failures.

    • Problem addressed: The authors state that medical GUIs require domain knowledge, have distinctive interface designs, and real systems cannot be publicly tested, and that safety verification beyond task completion is needed; existing benchmarks cover none of these.
    • Method highlights: 18 clinical scenarios across 10 medical domains, including 15 synthetic HTML scenarios reconstructed from product manuals, real OpenEMR v7.0.2 and the OHIF image viewer in Docker; 216 base tasks registered as 432 instances at dual intent/step granularity; agents operate only from screenshots, a deterministic checker scores five safety dimensions, and rewards carry severity penalties (critical 1.0 / major 0.3 / minor 0.05).
    • Main results: Among 23 agents, GPT-5.4 ranks first with a strict success rate of 54.2%, followed by Claude-Opus-4.7 at 52.6%; the open-source average is 2.5%, with the strongest, Qwen2.5-VL-32B, at 16.2% (Table 2). On the real OpenEMR layer, all models do not exceed 8.3%, while on the OHIF layer multiple open-source models reach 30% or above (Figure 4). Across 9,936 episodes, 0 critical violations were recorded, and failures were mainly step-budget exhaustion; closed-source failures were mostly exploration timeouts, while open-source failures were mostly format lock-up and heavy looping (Table J.1).
    • Authors' conclusions: The authors state that the current strongest agents remain far from clinical reliability, and that zero critical violations is only a lower-bound measurement under current capabilities rather than a safety conclusion; production-grade EHR screenshots, longer-horizon evaluation, and dense small-text interfaces are future directions. The benchmark code is open-sourced under Apache-2.0.
Read originalarxiv.org