From research goals to scientific closure: evaluating agents with evidence-supported physics researchFrom Research Goals to Scientific Closure: Evaluating Agents Through Evidence-Supported Physics Research
On PhysClosureBench, among seven frontier models, Claude-Opus-5 averaged 6.29/10 and had RC4 of 32.7%.
- Scientific conclusions depend on observable evidence, competing mechanisms, and valid scope, but existing benchmarks rarely evaluate whether an entire investigation answered the specified question. The authors therefore use physics tasks to evaluate whether agents can independently organize an investigation and reach scientific closure.
- PhysClosureBench contains 50 expert-verified physics tasks with given goals. Agents decide on computation and validation themselves in an offline environment with CPU and wall-clock limits. Atomic Score uses 20 half-point criteria to record partial completion, and Research Closure (RC0–RC4) judges whether the evidence and scope are sufficient to answer the question.
- Seven models, 150 attempts each. Claude-Opus-5 averages 6.29/10, RC4 32.7%; Gemini-3.1-Pro is 2.85/10, RC4 0.7%. Among attempts scoring ≥8/10, 36.2% did not reach RC4. The proportion of tasks reaching RC4 in all three runs is lower than at least once.
- The paper does not specifically discuss limitations. The evaluation covers 7 models, 50 tasks, and 3 runs per pair; automatic scoring uses GPT-5.6-Sol(high), with five experts spot-checking criterion judgments. The paper does not report statistical significance tests, inter-expert agreement, or the number of infrastructure reruns.
- Evaluated models
- Claude-Opus-5GPT-5.6-SolKimi-K3DeepSeek-V4.1-FlashQwen-3.8-MaxGLM-5.3-FlashGemini-3.1-Pro
- Benchmarks
- PhysClosureBench
- Metrics
- Atomic ScoreResearch Closure (RC0–RC4)RC4 ratefunctional completion
Researchers released PhysClosureBench, which uses 50 expert-verified physics research tasks to evaluate whether AI agents can carry research through to evidence-complete closure. The benchmark covers strong-field, attosecond and adjacent physics domains; each task provides only the research goal and core scientific constraints, and the agent must organize the research itself and generate and verify the required evidence. Scoring is divided into two parts: the Atomic Score over 20 criteria measures local research completion, while Research Closure (RC0 to RC4) judges the degree to which the research question is resolved based on whether the necessary evidence requirements and applicability conditions are met. Across seven frontier large language models, Claude-Opus-5 had the highest average Atomic Score at 6.29/10, but reached RC4 in only 32.7% of attempts; 36.2% of attempts scoring at least 8/10 still failed to reach RC4. Case analyses show that misreading generated results and unresolved physics applicability limits lead to incomplete closure.
Paper analysis
What problem does this paper attempt to solve?
The authors aim to evaluate whether an agent can independently complete the scientific closure of a specified physics problem.
Whether an agent can independently organize an investigation so that a specified physics research question reaches evidence-supported scientific closure.
- Scenario: The authors consider that agents can already assist with literature synthesis, scientific programming, and reproduction, but useful assistance does not equal the ability to independently organize an investigation toward a specified scientific goal. The authors use scientific closure to denote whether an investigation has sufficiently answered the research question, including deciding what evidence to generate and how to interpret and validate it.
- Existing gaps: The authors state that existing benchmarks evaluate final answers, executable code, machine-learning engineering artifacts, or research reproduction and research engineering tasks, but rarely evaluate whether an entire investigation has established a sufficiently supported answer. Obtaining a correct result or reproducing an existing finding may still leave the broader investigation incomplete.
- Why physics: The authors state that physics conclusions are tied to observable evidence, competing mechanisms, and an explicit valid scope, so they make research tasks with given goals and open routes.
- What this paper proposes: The authors propose PhysClosureBench, containing 50 expert-verified tasks. Atomic Score uses 20 predefined criteria to record partial scientific completion; Research Closure (RC0–RC4) looks at whether the indispensable evidence requirements and applicable scope conditions are satisfied.
- Central question: The authors ask whether agents can independently organize an investigation and reach scientific closure on a specified research question.
What related research exists?
Comparing against question-answering, coding, reproduction, and long-horizon physics benchmarks, the authors state that few directly evaluate scientific closure.
The authors describe related benchmarks in terms of question answering, research-level subquestions, executable research, and long-horizon physics tasks, and use Table 1 to mark whether each directly evaluates execution/artifacts, research decisions, evidence integration, and scientific closure. A check mark means direct evaluation, Partial means limited or indirect, and a cross means no explicit evaluation.
Expert-level question answering
- GPQA and HLE: GPQA by Rein et al. (2024) and Humanity's Last Exam by the Center for AI Safety et al. (2026) evaluate expert-level question answering. In Table 1, the authors mark all four columns for GPQA/HLE as not directly evaluated.
Research-level scientific subquestions
- CritPt: Zhu et al. (2026) evaluate compositional frontier physics challenges and finer, machine-verifiable checkpoints, including code-enabled evaluation. Table 1 marks only execution/artifacts as directly evaluated.
- FrontierScience-R: Wang et al. (2026) use fine-grained rubrics to evaluate expert-written PhD-level scientific subquestions. Table 1 marks research decisions as directly evaluated, evidence integration and scientific closure as Partial, and execution/artifacts as not directly evaluated.
Executable research and research engineering
- Research-process agents: The AI Scientist (Lu et al., 2024) and The AI Scientist-v2 (Yamada et al., 2025) explore experimental design, execution, and iterative analysis. The paper's experiments do not report running these two systems.
- Code, engineering, and reproduction: SciCode (Tian et al., 2024) focuses on scientific code generation; ScienceAgentBench (Chen et al., 2025) evaluates programs and execution results in data-driven tasks; MLE-Bench (Chan et al., 2025) and RE-Bench (Wijk et al., 2025) evaluate machine learning and research engineering; PaperBench (Starace et al., 2025) examines research reproduction. Table 1 marks research decisions and evidence integration for PaperBench and RE-Bench as Partial, and scientific closure as not directly evaluated.
Long-horizon physics tasks
- PRL-Bench: Miao et al. (2026) evaluate exploration-oriented long-horizon theoretical and computational tasks, including code execution and rubric scoring. The authors state that it is closer to physics research. Table 1 marks its execution/artifacts, research decisions, and evidence integration as directly evaluated, and scientific closure as Partial.
The authors position PhysClosureBench as making scientific closure at the level of a goal-given, agent-organized investigation an explicit evaluation target, distinguishing partial completion from whether the evidence, interpretation, and validation are sufficient to answer the original question, and checking whether complete closure is stable across independent attempts (Section 2). The experiments set no separate method baseline; the seven frontier models are what is evaluated.
How does the paper address this problem?
PhysClosureBench uses objective-given tasks and measures partial completion and closure separately with Atomic Score and RC0–RC4.
The authors build PhysClosureBench: tasks specify only the scientific goal and necessary constraints, while the investigation route, observables, and validation are decided by the agent; then the complementary Atomic Score and Research Closure look at partial completion and whether the question was answered, respectively (Figure 1, Figure 2).
Task setup and execution environment
- Given and open: Each task states the scientific goal, physical setup, relevant parameters, constraints, and computational resources, but does not specify a complete solution procedure, nor a fixed order of diagnostics and validation (Section 3.1).
- Sources and domains: The 50 tasks come from published research in Physical Review Letters, Physical Review A, and others, covering strong-field atoms/molecules and attosecond, solid-state and condensed-matter strong field, quantum optics, and the adjacent quantum light–matter regime. The counts in Figure 7 are: strong-field atoms/molecules/attosecond 24, solid-state and condensed-matter strong field 12, quantum optics and quantum light–matter 8, strong-field QED and relativistic 4, matter wave/Kapitza-Dirac 2.
- Resource boundaries: Tasks run in an isolated, offline, single-node environment. Agents allocate planning, exploration, analysis, and validation within task-level CPU and wall-clock limits. The limits in Table 4 range from 8 cores, 30 minutes to 96 cores, 720 minutes.
- Sessions: Each attempt is a separate OpenCode (v1.18.17) session, with Bash available to execute self-written scientific code in the container. At timeout or completion, the reports and artifacts available at that time are collected; timeout itself incurs no additional penalty (Section 4.1, Appendix A).
Task verification
- Traceable sources: Each question corresponds to a published study as the basis for the target phenomenon, physical regime, and scientific conclusion (Section 3.2).
- Expert process: A domain expert with ultrafast and strong-field research experience designed and supervised the semi-automated task construction and rubric process; other experts checked the scientific question, evidence requirements, premises, acceptable alternative evidence, and whether the instructions given to the agent and the hidden scoring criteria are kept separate (Appendix A.1).
- Included only after reproduction: Source results were manually reproduced before inclusion, confirming that the relevant values, physical trends, and conclusions can be recovered under the specified conditions. CPU and wall-clock were set according to the observed reproduction cost, with additional margin for planning, exploration, method selection, and intermediate failed attempts. The authors state that this makes the tasks feasible under the given resources, but does not restrict the agent to the reference reproduction path.
- Fixed before evaluation: Each case's task description, resource limits, and scoring rubric were finalized before model evaluation.
Two-layer scoring
- Atomic Score: 20 task-specific, predefined half-point criteria totaling 0–10, belonging to Formulation, Output, Identification, Mechanism, Validation/Scope (Table 2). It records how much of the relevant scientific work was done, without requiring the investigation itself to be complete.
- Criterion weights: The 50 questions have 1,000 atoms in total. The average share of full score by dimension is Formulation 16.4%, Output 19.2%, Identification 16.3%, Mechanism 36.9%, Validation/Scope 11.2% (Table 5).
- N/A and zero scores: If a conditional criterion does not apply, it is recorded as N/A, still contributes a fixed 0.5 points, and does not enter the numerator or denominator of the functional completion rate. Runs with no scientifically evaluable artifact are recorded as 0 and RC0 before atomic scoring, with no N/A points (Appendix B.1).
- Research Closure: RC0–RC4 are determined by the scientific requirements and their premises needed to answer the research question of that task; they are not a threshold on Atomic Score and are not tied to a fixed procedure (Table 3). RC4 means the required evidence and scope conditions are met; RC3 means the main conclusion is supported but substantive validation or scope gaps remain; RC2 means the core evidence is present but the central mechanism or other key requirements are unresolved; RC1 means the basic main output or branch is missing; RC0 means the central scientific object is invalid or missing. Adjacent levels depend on how the unmet requirement affects the main conclusion, not on which functional dimension it falls under.
Aggregation, automatic scoring, and evidence boundaries
- Functional completion rate: For F/O/I/M, an attempt's completion rate for a dimension is the proportion of applicable criteria satisfied in that dimension; the model value is the average of these attempt-level proportions, with attempts having no usable artifact contributing 0. Validation/Scope is instead aggregated as the proportion of applicable criteria satisfied within the group, because its applicability depends more on the method, evidence, and conclusion of that attempt (Section 4.2, Appendix C).
- Definition: The functional completion rate is written as xad=sad/nad, i.e., the number of satisfied atoms for attempt a in dimension d divided by the number of applicable atoms; N/A does not enter the numerator or denominator.
- Scorer: Evaluable submissions are scored by GPT-5.6-Sol(high) in stages: an independent initial evaluation under a fixed prompt and task rubric, then a targeted review that can see the initial evaluation; conditional adjudication is done only when a remaining substantive disagreement could affect Atomic Score, Research Closure, or attempt validity. The evaluated GPT-5.6-Sol configuration is xhigh, different from the high used for scoring (Section 4.1).
- Cannot supply analysis on the agent's behalf: Scoring is based only on evidence produced by the agent. Reviewers may inspect submitted artifacts and execution records, but reviewer-side checking cannot substitute for analysis or explanation missing from the submission. Invalid executions due to infrastructure are not counted as failures but rerun. Appendix H gives the shared rules and prompts for each stage.
What experiments did the paper conduct?
The authors state that a high partial score does not equal full closure: Claude-Opus-5 averaged 6.29/10 and had RC4 of 32.7%.
Experimental setup
- Tested models: Claude-Opus-5, GPT-5.6-Sol, Kimi-K3, DeepSeek-V4.1-Flash, Qwen-3.8-Max, GLM-5.3-Flash, Gemini-3.1-Pro. Among the first three, Claude-Opus-5, GPT-5.6-Sol, and Qwen-3.8-Max use xhigh, and the remaining four use high. Each model runs all 50 questions, each question 3 times, for a total of 1,050 scored attempts (Section 4.1).
- Tasks: 50 expert-verified physics tasks with given goals. Domain counts are in Figure 7. The paper sets no separate method baseline; the seven models are compared with each other.
- Runs: Each attempt has a separate workspace, with initial materials being the task description, resource limits, and tools, research conduct, and submission requirements. Code executes in an offline container. Unfinished computations, abandoned routes, and partial results at timeout are scored according to the available evidence; no evaluable result is recorded as 0 and RC0 (Section 4.1).
- Metrics: Mean Atomic Score (0–10); Research Closure distribution and attempt-level RC4 proportion; attempt-level functional completion rates for F/O/I/M. Also reported are the proportions of the 50 questions reaching RC4 at least once and reaching RC4 in all three runs (Section 4.2).
- Review: GPT-5.6-Sol(high) performs initial evaluation, targeted review, and conditional adjudication. Five experts with physics training reviewed 100 cards, covering all 50 questions, with two submissions from different models each time, for 200 requested criterion judgments in total. The criteria emphasize scientifically important, locally judgeable decisions, and the paper states that they are not an equiprobable sample of all rubric atoms. The agreement rate between the 192 valid judgments and the automatic atomic judgments is 81.8%; the closure-related comparison covers 84 judgments, 72 cards, and 44 questions, with 60 of 79 binary judgments in agreement (75.9%) (Section 4.1, Appendix B.2).
- Unit of analysis: A single attempt. Unless otherwise stated, model results aggregate to 150 attempts per model. The cells in Figure 4A are percentages of all 1,050 attempts, not the conditional RC proportion within that score band (Appendix C).
Main results
Mean Atomic Score and RC4 come from Table 12, RC0 from Table 8. Each row is that model's 150 attempts.
Swipe horizontally to read the table
Model (reasoning effort) Mean Atomic Score RC4 RC0 Claude-Opus-5 (xhigh) 6.29/10 32.7% 16.0% GPT-5.6-Sol (xhigh) 5.83/10 22.7% 18.7% Kimi-K3 (high) 5.17/10 19.3% 32.0% DeepSeek-V4.1-Flash (high) 4.50/10 10.7% 50.0% Qwen-3.8-Max (xhigh) 3.46/10 7.3% 50.7% GLM-5.3-Flash (high) 3.28/10 5.3% 58.0% Gemini-3.1-Pro (high) 2.85/10 0.7% 50.7% - Ranking and closure: The authors state that Research Closure broadly follows the model ranking of Atomic Score, but even for the leading model, most investigations did not reach complete closure.
- By dimension: The authors report that Formulation has the highest completion rate among F/O/I/M for every model, and consider that current systems are relatively better at establishing the scientific setup. Claude-Opus-5's F/O/I/M are 85.6%, 60.1%, 54.6%, 52.8% (Table 6). The authors state that the relative advantage of stronger models is more evident in Output, and report that the remaining models' Output is 37.3% or lower.
- RC4 and RC0 can coexist: The authors cite DeepSeek-V4.1-Flash as an example, stating that a relatively high complete-closure proportion can coexist with many attempts that failed to establish the basic scientific foundation of the task. The authors state that the two figures together show the gap between partial completion and complete closure (Section 5.1).
High-scoring attempts and incomplete closure
- What was measured: Figure 4 places the Atomic Score and RC of all 1,050 attempts together, and separately examines which applicable criteria attempts scoring at least 8/10 still lack.
- Results: The authors report that higher Atomic Score broadly corresponds to higher RC. Of the 229 attempts scoring at least 8/10, 83 (36.2%) did not reach RC4, of which 55 were still at RC2. These high-scoring attempts that did not reach RC4 satisfied almost all Formulation and Output criteria, but 16.0% of Identification and 20.8% of Mechanism were unsatisfied; the corresponding proportions in the RC4 group (n=146) are 2.1% and 3.0%. Among the Validation/Scope criteria applicable across the benchmark, scope argumentation was satisfied 86.9%, task-required validation 59.6%, and risk-triggered validation 47.8% (Figure 4, Table 10).
- The authors' interpretation: The authors consider that delivering the required results does not mean their scientific meaning has been established. One example generated the required spectrum and separated contributions but did not connect it to the physical mechanism. In another, the main mechanism was established, but an applicability issue exposed by the agent's own computation remained unresolved. The authors state that handling such issues requires corresponding validation, or restricting conclusions to the range supported by the evidence.
Closure across repeated runs
- What was measured: Figure 6 and Table 12 compare, for each model on the 50 tasks, the proportion reaching RC4 at least once and the proportion reaching RC4 in all three independent runs.
- Results: Claude-Opus-5 is 50.0% vs. 18.0%, GPT-5.6-Sol 40.0% vs. 10.0%, Kimi-K3 40.0% vs. 4.0%, DeepSeek-V4.1-Flash 24.0% vs. 0.0%, Qwen-3.8-Max 14.0% vs. 2.0%, GLM-5.3-Flash 12.0% vs. 0.0%, Gemini-3.1-Pro 2.0% vs. 0.0%.
- The authors' interpretation: The authors state that these two proportions distinguish "being able to reach closure on some question" from "stably reaching closure across independent runs." The authors state that requiring RC4 in all three runs is much stricter than at least once; even the strongest model can show that a question can be closed but cannot do so stably across repeated investigations. The paper does not separately explain the pair of numbers where Qwen-3.8-Max's all-three-runs proportion is 2.0% while DeepSeek-V4.1-Flash's is 0.0%.
Different evidence paths on the same task
- What was measured: Figure 5 and Appendix E compare three representative submissions for Case 30. The question is whether central-potential scattering after release can explain the intensity-dependent attoclock shift, and how far the conclusions on the Coulomb potential can be supported under a screened potential with the same binding energy.
- Results: Kimi-K3 is 10.0/RC4, GPT-5.6-Sol 9.5/RC3, Gemini-3.1-Pro 4.5/RC2. After correcting an inconsistent angle sign, Kimi-K3 reduced the difference between the two algorithms to 4.53×10−7 rad, explained the screening dependence using the relative size of the tunneling exit distance and the screening length, and restricted the physical interpretation to quasi-static, under-barrier exit. GPT-5.6-Sol explained the change in screening dependence, but in the E0=0.08 a.u. diagnostic, the field strength is above the barrier-suppression threshold EBSI=0.0625 a.u. of the Coulomb reference, and the final report did not reconcile this diagnostic with the high-field interpretation. Gemini-3.1-Pro generated the shifts for the Coulomb and screened potentials but described the intensity dependence as monotonically decreasing; the saved λ=1–3 curves rise, and λ=5 and 10 first rise then fall.
- The authors' interpretation: The authors state that this comparison distinguishes two kinds of non-closure: misinterpretation of an already-computed trend, and a supported mechanism with unresolved applicability limits. The paths in Figure 5 are described by the authors as illustrative, not execution time, Atomic Score, or intermediate RC.
Other ablations and analyses
- Output completion rates in Table 6: GPT-5.6-Sol 60.5%, Claude-Opus-5 60.1%, Kimi-K3 49.7%, DeepSeek-V4.1-Flash 37.3%, Qwen-3.8-Max 28.7%, GLM-5.3-Flash 23.7%, Gemini-3.1-Pro 22.7%.
- Validation/Scope applicable-criteria satisfaction rates in Table 6: Claude-Opus-5 84.0% (263/313), GPT-5.6-Sol 74.2% (241/325), Kimi-K3 68.4% (214/313), DeepSeek-V4.1-Flash 71.3% (214/300), Qwen-3.8-Max 54.7% (156/285), GLM-5.3-Flash 65.6% (177/270), Gemini-3.1-Pro 47.8% (121/253).
- Table 10: scope argumentation 86.9% (852/981), task-required validation 59.6% (93/156), risk-triggered validation 47.8% (441/922).
- RC3 in Table 8 ranges from 0.7% for Gemini-3.1-Pro to 4.7% for GPT-5.6-Sol. Appendix D.1 states that all 26 RC3 attempts still had an unsatisfied applicable V criterion, of which 25 simultaneously satisfied another V criterion.
- Medians in Table 12: Claude-Opus-5 6.75, GPT-5.6-Sol 6.00, Kimi-K3 5.00, DeepSeek-V4.1-Flash 4.00, Gemini-3.1-Pro 2.50, GLM-5.3-Flash 2.25, Qwen-3.8-Max 2.00.
- Table 9: Claude-Opus-5's RC4 counts across three runs are 20, 16, 13 (50 attempts each); Gemini-3.1-Pro is 1, 0, 0.
What are some points that can be further explored?
The paper does not write limitations or future directions as a dedicated section.
Limitations and future directions noted by the authors
The paper does not specifically discuss limitations, nor does it write out future directions as future work. The sentences in the conclusion about what evaluation should also look at are a summary of the results, not stated limitations or plans.
Scope of experimental coverage
- Models and number of runs: The models tested are Claude-Opus-5, GPT-5.6-Sol, Kimi-K3, DeepSeek-V4.1-Flash, Qwen-3.8-Max, GLM-5.3-Flash, and Gemini-3.1-Pro, 7 in total; each model has 50 questions, each question 3 times, for a total of 1,050 scored attempts. Reasoning effort is xhigh for the first two and Qwen-3.8-Max, and high for the remaining four (Section 4.1).
- Tasks and environment: Tasks come from published physics research and were manually reproduced before inclusion. The domain counts in Figure 7 are 24, 12, 8, 4, 2. The runtime environment is an offline isolated container, with CPU and wall-clock limits given per task, from 8 cores, 30 minutes to 96 cores, 720 minutes in Table 4 (Section 3.2, Appendix A).
- Scoring: The automatic scorer is GPT-5.6-Sol(high), which is not the same reasoning effort as GPT-5.6-Sol (xhigh) as a tested model. Five physics experts reviewed 100 cards covering all 50 questions; of 200 requested criterion judgments, 192 were valid. The paper states that the criterion selection is not an equiprobable sample of all rubric atoms (Section 4.1, Appendix B).
- Aggregation: The main unit of analysis is a single attempt; model-level results aggregate 50 questions × 3 times unless otherwise stated. Repeated closure additionally reports the proportion of the 50 questions with RC4 at least once and with RC4 in all three runs (Section 4.2, Figure 6).
- Items not reported by the paper: The paper does not report statistical significance tests, agreement among the five experts, the number of reruns after infrastructure failures, or the actual wall-clock usage of each attempt.
Summarize the main content of the paper
Partial completion of seven models on PhysClosureBench, which the authors state does not guarantee complete and stable closure.
PhysClosureBench is used to evaluate whether a scientific agent can bring a given physics objective to an evidence-supported closure, rather than only looking at whether the answer is correct or whether a runnable artifact is delivered.
- Problem: The authors argue that assisting with literature, programming, and reproduction is not yet equivalent to being able to independently organize an investigation and answer a specified question. Existing benchmarks rarely judge whether an entire investigation has established a sufficiently supported answer.
- Approach: 50 tasks specify the objective, physical setup, parameters, constraints, and computational resources, but do not specify the solution process. Agents implement, compare, and verify on their own in an environment with no network access and with CPU and wall-clock limits. Atomic Score uses 20 half-point criteria and records partial completion by F/O/I/M/V; RC0–RC4 judges whether the investigation answered the question according to that task's evidence and scope-of-applicability requirements, and is not determined by a score threshold.
- Main results: Seven frontier models each made 150 attempts. Claude-Opus-5 averaged an Atomic Score of 6.29/10 and RC4 32.7%; Gemini-3.1-Pro was 2.85/10 and 0.7% (Table 12). Among the 229 attempts scoring at least 8/10, 36.2% did not reach RC4 (Section 5.2).
- Stability: Claude-Opus-5 reached RC4 at least once on 50.0% of tasks, and reached it in all three runs on 18.0%. For all seven models, the proportion reaching it in all three runs was lower than the proportion reaching it at least once (Table 12).
- Authors' conclusion: The authors state that higher partial completion is usually accompanied by a higher closure level, but high-scoring investigations are not necessarily fully closed. In individual cases, lack of closure can come from misreading a trend that has already been computed, or from a mechanism being supported while applicability limitations remain unresolved. The authors argue that one needs to look simultaneously at how much scientific work was completed, whether the investigation went from the question to a supported conclusion, and how stable full closure is across independent runs.